Comparison of PCR nucleic acid hybridization and EIA for the detection of Chlamydia trachomatis in different populations in a regional centre

被引:4
|
作者
Farrell, DJ
Haran, MV
Park, BW
机构
[1] TOOWOOMBA GEN HOSP,SEXUAL HLTH CLIN,TOOWOOMBA,QLD 4350,AUSTRALIA
[2] TOOWOOMBA GEN HOSP,DEPT OBSTET & GYNAECOL,TOOWOOMBA,QLD 4350,AUSTRALIA
[3] TOOWOOMBA GEN HOSP,PUBL HLTH CLIN,TOOWOOMBA,QLD 4350,AUSTRALIA
关键词
Chlamydia trachomatis; PCR; Amplicor(TM); VIDAS(TM); IDEIA(TM);
D O I
10.1080/00313029600169583
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Culture on McCoy cell monolayers has been accepted as the reference method for the detection of Chlamydia trachomatis. Recent studies have shown that polymerase chain reaction (PCR)/nucleic acid hybridization based methods have increased sensitivity over culture while still retaining specificity. In situations where organism viability is of concern, due to factors such as transportation delays, culture is inappropriate. Regional laboratories therefore have not been able to utilize the reference method and have been forced to use less reliable methods. The aims of our study were to assess the feasibility of performing PCR to diagnose infections due to C. trachomatis in a regional laboratory using a new commercial kit - AmplicorTM (Roche Molecular Systems, Branchburg, NJ) and to compare the current enzyme-immunoassay (EIA) based-methods used in our laboratory (VIDASTM [bioMerieux Vitek, Hazelwood MO] and IDEIATM [Novo Nordisk Diagnostics, Cambridge, UK]) against PCR. Thirteen positive AmplicorTM specimens were found in 267 urine specimens collected from asymptomatic adolescent males and females. All 13 were confirmed positive using major outer membrane protein gene PCR (MOMP). VIDASTM and IDEIATM showed 100% correlation to each other but only detected 5/13 positives. Of 140 consecutive patients attending the regional sexual health clinic, 13 were AmplicorTM positive, 11/13 MOMP positive and 10/13 positive by VIDASTM. Five of 254 patients attending the hospital antenatal clinic were positive by AmplicorTM, all being confirmed by MOMP. No PCR inhibition was detected in a random sample of 100 varied negative AmplicorTM tests using a modification of the AmplicorTM kit. No contamination was experienced. The AmplicorTM kit was shown to be suitable for use in the routine clinical laboratory with minimal disruption to workflow. For regional laboratories this kit should provide more accurate results than EIA based methods, particularly in the detection of asymptomatic persons.
引用
收藏
页码:74 / 79
页数:6
相关论文
共 50 条
  • [31] Comparison of the PACE 2 assay, two amplification assays, and clearview EIA for detection of Chlamydia trachomatis in female endocervical and urine specimens
    Lauderdale, TL
    Landers, L
    Thorneycroft, I
    Chapin, K
    JOURNAL OF CLINICAL MICROBIOLOGY, 1999, 37 (07) : 2223 - 2229
  • [32] COMPARISON OF THE KALLESTED PATHFINDER EIA, CYTOCENTRIFUGED DIRECT FLUORESCENT-ANTIBODY, AND CELL-CULTURE FOR THE DETECTION OF CHLAMYDIA-TRACHOMATIS
    LEBAR, W
    SCHUBINER, H
    JEMAL, C
    HERSCHMAN, B
    CRISWELL, K
    CURTIN, N
    SHERBECK, M
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 1991, 14 (01) : 17 - 20
  • [33] Detection of Chlamydia trachomatis infections in women by amplicor PCR: Comparison of diagnostic performance with urine and cervical specimens
    Pasternack, R
    Vuorinen, P
    Kuukankorpi, A
    Pitkajarvi, T
    Miettinen, A
    JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (04) : 995 - 998
  • [34] Comparison of synovial tissue and synovial fluid as the source of nucleic acids for detection of Chlamydia trachomatis by polymerase chain reaction
    Branigan, PJ
    Gerard, HC
    Hudson, AP
    Schumacher, HR
    ARTHRITIS AND RHEUMATISM, 1996, 39 (10): : 1740 - 1746
  • [35] Comparison of methods for detection of Chlamydia trachomatis and Neisserza gonorrhoeae using commercially available nucleic acid amplification tests and a liquid pap smear medium
    Koumans, EH
    Black, CM
    Markowitz, LE
    Unger, ER
    Pierce, A
    Sawyer, MK
    Papp, JR
    JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (04) : 1507 - 1511
  • [36] Multicenter Comparison of Nucleic Acid Amplification Tests for the Diagnosis of Rectal and Oropharyngeal Chlamydia trachomatis and Neisseria gonorrhoeae Infections
    Van Der Pol, Barbara
    Chernesky, Max
    Gaydos, Charlotte A.
    Hook, Edward W., III
    Joseph, Ajith M.
    Christensen, Katherine
    Arcenas, Rodney
    Boutwell, Alexander
    Wiesenfeld, Harold C.
    Taylor, Stephanie N.
    Mayer, Kenneth H.
    Golden, Matthew R.
    Moncada, Jeanne
    Jang, Dan
    Schachter, Julius
    JOURNAL OF CLINICAL MICROBIOLOGY, 2022, 60 (01)
  • [37] Volume effect on sensitivity of nucleic acid amplification tests for detection of Chlamydia trachomatis in urine specimens from females
    Moncada, J
    Chow, JM
    Schachter, J
    JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (10) : 4842 - 4843
  • [38] Comparative Evaluation of 2 Nucleic Acid Amplification Tests for the Detection of Chlamydia trachomatis and Neisseria gonorrhoeae at Extragenital Sites
    Bristow, Claire C.
    McGrath, Mark R.
    Cohen, Adam C.
    Anderson, Laura J.
    Gordon, Kristie K.
    Klausner, Jeffrey D.
    SEXUALLY TRANSMITTED DISEASES, 2017, 44 (07) : 398 - 400
  • [39] Comparison of an in-house PCR assay, direct fluorescence assay and the Roche AMPLICOR Chlamydia trachomatis kit for detection of C. trachomatis
    Sachdeva, Poonam
    Patel, Achchhe Lal
    Sachdev, Divya
    Ali, Mashook
    Mittal, Aruna
    Saluja, Daman
    JOURNAL OF MEDICAL MICROBIOLOGY, 2009, 58 (07) : 867 - 873
  • [40] Comparison of serological assays for detection of Chlamydia trachomatis antibodies in different groups of obstetrical and gynecological patients
    Bax, CJ
    Mutsaers, JAEM
    Jansen, CL
    Trimbos, JB
    Dörr, PJ
    Oostvogel, PM
    CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2003, 10 (01) : 174 - 176