Comparison of the PACE 2 assay, two amplification assays, and clearview EIA for detection of Chlamydia trachomatis in female endocervical and urine specimens

被引:27
|
作者
Lauderdale, TL
Landers, L
Thorneycroft, I
Chapin, K
机构
[1] Univ S Alabama, Dept Pathol, Mobile, AL 36688 USA
[2] Univ S Alabama, Dept Obstet & Gynecol, Mobile, AL 36688 USA
关键词
D O I
10.1128/JCM.37.7.2223-2229.1999
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Screening for sexually transmitted diseases (STDs) in a greater proportion of sexually active patients has become an accepted protocol by most health care providers. The purpose of this study was to compare the current test methods for detection of Chlamydia trachomatis used at the University of South Alabama, the PACE 2 assay (Gen-Probe) and the Clearview EIA (Wampole Laboratories), with two amplification technologies, the AMP CT (Gen Probe) and LCx (Abbott) assays. In addition, a number of demographic parameters,were ascertained by asking questions at the time of examination as well as for health care provider concerns and preferences. One urine and four endocervical swab specimens were collected in random order from 787 female patients attending one of four obstetrics-gynecology clinics. Eighty-seven percent of patients had no STD-related symptoms. Patients were considered positive for C. trachomatis if three or more assays (swab and/or urine) were positive. Abbott and Gen-Probe confirmed discrepant results by alternate amplified assays. A total of 66 true-positive specimens were detected by use of the combination of endocervical swabs and urine specimens, After discrepant analysis, sensitivities for endocervical swab specimens for the EIA and the PACE 2, LCx, and AMP CT assays were 50, 81, 97, and 100%, respectively. Sensitivities for the LCx and AMP CT assays with urine specimens a ere 98 and 81%, respectively. The prevalence of C. trachomatis was 8.4%, as determined by amplification technology. Overall, the amplification technologies were the most sensitive methods with either swab (AMP CT assay) or urine (LCx assay) specimens, The PACE 2 assay offered the advantage of a simpler and less expensive assay with acceptable sensitivity. The clearview CT EIA, while yielding a rapid in-office result, had unacceptably low sensitivity. The wide variation in performance with amplification assays with urine specimens as reported in both this study and the literature obviates the need to clarify optimal parameters for this specimen type.
引用
收藏
页码:2223 / 2229
页数:7
相关论文
共 50 条
  • [1] COMPARISON OF THE CLEARVIEW CHLAMYDIA, THE PACE 2 ASSAY, AND CULTURE FOR DETECTION OF CHLAMYDIA-TRACHOMATIS FROM CERVICAL SPECIMENS IN A LOW-PREVALENCE POPULATION
    BLANDING, J
    HIRSCH, L
    STRANTON, N
    WRIGHT, T
    AARNAES, S
    DELAMAZA, LM
    PETERSON, EM
    JOURNAL OF CLINICAL MICROBIOLOGY, 1993, 31 (06) : 1622 - 1625
  • [2] Performance of the APTIMA Combo 2 assay for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in female urine and endocervical swab specimens
    Gaydos, CA
    Quinn, TC
    Willis, D
    Weissfeld, A
    Hook, EW
    Martin, DH
    Ferrero, DV
    Schachter, J
    JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (01) : 304 - 309
  • [3] Comparative evaluation of Chlamydiazyme, PACE 2, and AMP-CT assays for detection of Chlamydia trachomatis in endocervical specimens
    Wylie, JL
    Moses, S
    Babcock, R
    Jolly, A
    Giercke, S
    Hammond, G
    JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (12) : 3488 - 3491
  • [4] Evaluation of a new amplified enzyme immunoassay (EIA) for the detection of Chlamydia trachomatis in male urine, female endocervical swab, and patient obtained vaginal swab specimens
    Tanaka, M
    Nakayama, H
    Sagiyama, K
    Haraoka, M
    Yoshida, H
    Hagiwara, T
    Akazawa, K
    Naito, S
    JOURNAL OF CLINICAL PATHOLOGY, 2000, 53 (05) : 350 - 354
  • [5] Comparison of three nucleic acid amplification tests for detection of Chlamydia trachomatis in urine specimens
    Gaydos, CA
    Theodore, M
    Dalesio, N
    Wood, BJ
    Quinn, TC
    JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (07) : 3041 - 3045
  • [6] Comparison of three nucleic acid amplification tests for the detection of Chlamydia trachomatis in urine specimens
    Theodore, ML
    Dalesio, N
    Wood, BJ
    Quinn, TC
    Gaydos, C
    CLINICAL INFECTIOUS DISEASES, 2001, 33 (07) : 1246 - 1246
  • [7] Detection of Chlamydia trachomatis by the Gen-Probe AMPLIFIED Chlamydia Trachomatis Assay (AMP CT) in urine specimens from men and women and endocervical specimens from women
    Crotchfelt, KA
    Pare, B
    Gaydos, C
    Quinn, TC
    JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (02) : 391 - 394
  • [8] Detection of Chlamydia trachomatis in male and female urine specimens by using the amplified Chlamydia trachomatis test
    Mouton, JW
    Verkooyen, R
    vanderMeijden, WI
    vanRijsoortVos, TH
    Goessens, WHF
    Kluytmans, JAJW
    Deelen, SDA
    Luijendijk, A
    Verbrugh, HA
    JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (06) : 1369 - 1372
  • [9] Evaluation of Chlamydia trachomatis and Neisseria gonorrhoeae Detection in Urine, Endocervical, and Vaginal Specimens by a Multiplexed Isothermal Thermophilic Helicase-Dependent Amplification (tHDA) Assay
    O'Neil, Dominic
    Doseeva, Victoria
    Rothmann, Thomas
    Wolff, John
    Nazarenko, Irina
    JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (12) : 4121 - 4125
  • [10] Comparative Evaluation of BDProbeTec ET, LCx and PACE 2 Assays for the Detection of Chlamydia trachomatis in Urogenital Specimens
    C. Pollara
    L. Terlenghi
    M. A. De Francesco
    F. Gargiulo
    F. Perandin
    N. Manca
    European Journal of Clinical Microbiology and Infectious Diseases , 2003, 22 : 512 - 514