Audit feasibility for geometric distortion in magnetic resonance imaging for radiotherapy

被引:9
|
作者
Alzahrani, Meshal [1 ,2 ]
Broadbent, David A. [3 ]
Chuter, Robert [4 ,5 ]
Al-Qaisieh, Bashar [3 ]
Jackson, Steven [4 ]
Michael, Hutton [4 ]
Johnstone, Robert, I [6 ]
Shah, Simon [6 ]
Wetscherek, Andreas [7 ,8 ]
Chick, H. Joan [7 ,8 ]
Wyatt, Jonathan J. [9 ,10 ]
McCallum, Hazel Mhairi [9 ,10 ]
Speight, Richard [3 ]
机构
[1] King Abdulaziz Univ, Fac Appl Med Sci, Dept Diagnost Radiol, Jeddah, Saudi Arabia
[2] Univ Leeds, Leeds Inst Cardiovasc & Metab Med, Biomed Imaging Sci Dept, Leeds, W Yorkshire, England
[3] Leeds Teaching Hosp NHS Trust, Dept Med Phys & Engn, Leeds, W Yorkshire, England
[4] Christie NHS Fdn Trust, Christie Med Phys & Engn CMPE, Manchester, Lancs, England
[5] Univ Manchester, Fac Biol Med & Hlth, Div Canc Sci, Manchester, Lancs, England
[6] Guys & St Thomas NHS Fdn Trust, London, England
[7] Inst Canc Res, Joint Dept Phys, London, England
[8] Royal Marsden NHS Fdn Trust, London, England
[9] Newcastle Upon Tyne Hosp NHS Fdn Trust, Northern Ctr Canc Care, Newcastle Upon Tyne, Tyne & Wear, England
[10] Newcastle Univ, Ctr Canc, Newcastle Upon Tyne, Tyne & Wear, England
关键词
Magnetic resonance imaging; Geometric distortion; Radiotherapy; Quality assurance; Audit; RADIATION-THERAPY; MRI; PRECISION; ACCURACY; IMPACT;
D O I
10.1016/j.phro.2020.07.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Magnetic Resonance Imaging (MRI) is increasingly being used in radiotherapy (RT). However, geometric distortions are a known challenge of using MRI in RT. The aim of this study was to demonstrate feasibility of a national audit of MRI geometric distortions. This was achieved by assessing large field of view (FOV) MRI distortions on a number of scanners used clinically for RT. Materials and methods: MRI scans of a large FOV MRI geometric distortion phantom were acquired on 11 MRI scanners that are used clinically for RT in the UK. The mean and maximum distortions and variance between scanners were reported at different distances from the isocentre. Results: For a small FOV representing a brain (100-150 mm from isocentre) all distortions were < 2 mm except for the maximum distortion of one scanner. For a large FOV representing a head and neck/pelvis (200-250 mm from isocentre) mean distortions were < 2 mm except for one scanner, maximum distortions were > 10 mm in some cases. The variance between scanners was low and was found to increase with distance from isocentre. Conclusions: This study demonstrated feasibility of the technique to be repeated in a country wide geometric distortion audit of all MRI scanners used clinically for RT. Recommendations were made for performing such an audit and how to derive acceptable limits of distortion in such an audit.
引用
收藏
页码:80 / 84
页数:5
相关论文
共 50 条
  • [1] Geometric Distortion in Structural Magnetic Resonance Imaging
    Wang, Deming
    Doddrell, David M.
    CURRENT MEDICAL IMAGING REVIEWS, 2005, 1 (01) : 49 - 60
  • [2] Diffusion-weighted magnetic resonance imaging in radiotherapy: Do not forget about geometric distortion
    Leroy, T.
    Renard, B.
    Ceugnart, L.
    Lemaitre, L.
    Lopes, R.
    Beauguitte, A.
    Lartigau, E.
    Pasquier, D.
    EUROPEAN JOURNAL OF CANCER, 2013, 49 : S223 - S224
  • [3] The Impact of System-Related Magnetic Resonance Imaging Geometric Distortion in Stereotactic Radiotherapy: A Case Report
    Kumagai, Motoki
    Kawamura, Mariko
    Kato, Yutaka
    Okudaira, Kuniyasu
    Naganawa, Shinji
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (07)
  • [4] Reproducibility of geometric distortion in magnetic resonance imaging based on phantom studies
    Mizowaki, T
    Nagata, Y
    Okajima, K
    Kokubo, M
    Negoro, Y
    Araki, N
    Hiraoka, M
    RADIOTHERAPY AND ONCOLOGY, 2000, 57 (02) : 237 - 242
  • [5] Influence of different inhomogeneities on the geometric distortion in stereotactic magnetic resonance imaging
    Novotny, J
    Vymazal, J
    Chuda, P
    Urgosik, D
    Novotny, J
    Liscak, R
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S213 - S213
  • [6] Evaluation of Spatial-encoding-related Geometric Distortion in Magnetic Resonance Imaging
    Hong, Cheol Pyo
    Lee, Dong Hoon
    Lee, Man Woo
    Woo, Youngkeun
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 61 (12) : 2068 - 2072
  • [7] Evaluation of spatial-encoding-related geometric distortion in magnetic resonance imaging
    Cheol Pyo Hong
    Dong Hoon Lee
    Man Woo Lee
    Youngkeun Woo
    Journal of the Korean Physical Society, 2012, 61 : 2068 - 2072
  • [8] Quantification of Geometric Distortion in Magnetic Resonance Imaging for Radiation Therapy Treatment Planning
    Slagowski, J. M.
    Ding, Y.
    Wen, Z.
    Fuller, C. D.
    Chung, C.
    Kadbi, M.
    Ibbott, G. S.
    Wang, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E547 - E547
  • [9] A Preliminary Study of the Geometric Distortion in Diffusion-Weighted Imaging of Magnetic Resonance Imaging Simulation
    Liu, X.
    Qiu, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E328 - E329
  • [10] A Preliminary Study of the Geometric Distortion in Diffusion-Weighted Imaging of Magnetic Resonance Imaging Simulation
    Liu, X.
    Qiu, J.
    MEDICAL PHYSICS, 2020, 47 (06) : E510 - E510