On-line blood and dialysate sampling system for multiparametric monitoring during dialysis

被引:0
|
作者
Lurzer, W [1 ]
Scharfetter, H [1 ]
Hutten, H [1 ]
机构
[1] Graz Univ Technol, Inst Biomed Engn, A-8010 Graz, Austria
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A microprocessor-controlled sampling system has been developed for the combination with a commercially available measurement system for electrolytes, blood gases and other substances. Samples can be withdrawn from blood and dialysate during hemodialysis, All safety aspects have been considered carefully. Tile system is free programmable.
引用
收藏
页码:77 / 78
页数:2
相关论文
共 50 条
  • [1] Ionic dialysance as a method for the on-line monitoring of delivered dialysis without blood sampling
    Manzoni, C
    DiFilippo, S
    Corti, M
    Locatelli, F
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 1996, 11 (10) : 2023 - 2030
  • [2] Ion-selective optical sensor for continuous on-line monitoring of dialysate sodium during dialysis
    Sharma, Manoj K.
    Frijns, Arjan J. H.
    Mandamparambil, Rajesh
    Kooman, Jeroen P.
    Smeulders, David M. J.
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS XVII, 2017, 10058
  • [3] On-Line Dialysate Infusion to Estimate Absolute Blood Volume in Dialysis Patients
    Schneditz, Daniel
    Schilcher, Gernot
    Ribitsch, Werner
    Krisper, Peter
    Haditsch, Bernd
    Kron, Joachim
    ASAIO JOURNAL, 2014, 60 (04) : 436 - 442
  • [4] Estimation of delivered dialysis dose by on-line monitoring of the ultraviolet absorbance in the spent dialysate
    Uhlin, F
    Fridolin, I
    Lindberg, LG
    Magnusson, M
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2003, 41 (05) : 1026 - 1036
  • [5] DIALYSATE CONSUMPTION AND DIALYSIS DOSE IN ON-LINE HEMODIAFILTRATION WITH AUTOMATED COUPLING DIALYSATE/BLOOD FLOW FUNCTION (AUTOFLOW FUNCTION)
    Park, Yongki
    Jeon, Jimin
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2012, 27 : 206 - 207
  • [6] Monitoring on-line treated water and dialysate quality
    Sobrino Perez, P-E.
    Barril Cuadrado, G.
    del Rey Roman, C.
    Sachez Tomero, J. A.
    NEFROLOGIA, 2008, 28 (05): : 493 - 504
  • [7] An On-line Multiparametric Water Quality Monitoring System Based on Visible Spectrophotometry
    Liao, Haiyang
    Tian, Peng
    Du, Yu
    Wen, Zhiyu
    MANUFACTURING PROCESS TECHNOLOGY, PTS 1-5, 2011, 189-193 : 2801 - 2804
  • [8] Conductivity: on-line monitoring of dialysis adequacy
    Del Vecchio, L
    Di Filippo, S
    Andrulli, S
    Manzoni, C
    Corti, M
    Barbisoni, F
    Locatelli, F
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1998, 21 (09): : 521 - 525
  • [9] A novel biosensor for on-line dialysis monitoring
    Stanecki, CE
    McShane, MJ
    Hannibal, AM
    Watts, A
    Driggers, K
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 3009 - 3011
  • [10] «On-line» Preparation of Bicarbonate-containing Dialysate for Use in Peritoneal Dialysis
    Ing, T.S.
    Quon, M.J.
    Daugirdas, J.T.
    Liu, P.
    Gandhi, V.C.
    Reid, R.R.
    International Journal of Artificial Organs, 1981, 4 (06): : 308 - 309