Convolution-based estimation of organ dose in tube current modulated CT

被引:23
|
作者
Tian, Xiaoyu [1 ,2 ]
Segars, W. Paul [2 ,3 ,4 ]
Dixon, Robert L. [5 ]
Samei, Ehsan [1 ,2 ,3 ,4 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27705 USA
[2] Duke Univ, Carl E Ravin Adv Imaging Labs, Durham, NC 27705 USA
[3] Duke Univ, Dept Radiol, Durham, NC 27705 USA
[4] Duke Univ, Med Phys Grad Program, Durham, NC 27705 USA
[5] Wake Forest Univ, Bowman Gray Sch Med, Dept Radiol, Winston Salem, NC 27103 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 10期
关键词
CT; computed tomography; Monte Carlo; organ dose; tube current modulation; patient specific; COMPUTATIONAL PHANTOMS; COMPUTED-TOMOGRAPHY; PEDIATRIC CHEST; OPTIMIZATION;
D O I
10.1088/0031-9155/61/10/3935
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Estimating organ dose for clinical patients requires accurate modeling of the patient anatomy and the dose field of the CT exam. The modeling of patient anatomy can be achieved using a library of representative computational phantoms (Samei et al 2014 Pediatr. Radiol. 44 460-7). The modeling of the dose field can be challenging for CT exams performed with a tube current modulation (TCM) technique. The purpose of this work was to effectively model the dose field for TCM exams using a convolution-based method. A framework was further proposed for prospective and retrospective organ dose estimation in clinical practice. The study included 60 adult patients (age range: 18-70 years, weight range: 60-180 kg). Patient-specific computational phantoms were generated based on patient CT image datasets. A previously validated Monte Carlo simulation program was used to model a clinical CT scanner (SOMATOM Definition Flash, Siemens Healthcare, Forchheim, Germany). A practical strategy was developed to achieve real-time organ dose estimation for a given clinical patient. CTDIvol-normalized organ dose coefficients (h(Organ)) under constant tube current were estimated and modeled as a function of patient size. Each clinical patient in the library was optimally matched to another computational phantom to obtain a representation of organ location/distribution. The patient organ distribution was convolved with a dose distribution profile to generate (CTDIvol)(organ, convolution) values that quantified the regional dose field for each organ. The organ dose was estimated by multiplying (CTDIvol)(organ,) (convolution) with the organ dose coefficients (h(Organ)). To validate the accuracy of this dose estimation technique, the organ dose of the original clinical patient was estimated using Monte Carlo program with TCM profiles explicitly modeled. The discrepancy between the estimated organ dose and dose simulated using TCM Monte Carlo program was quantified. We further compared the convolution-based organ dose estimation method with two other strategies with different approaches of quantifying the irradiation field. The proposed convolution-based estimation method showed good accuracy with the organ dose simulated using the TCM Monte Carlo simulation. The average percentage error (normalized by CTDIvol) was generally within 10% across all organs and modulation profiles, except for organs located in the pelvic and shoulder regions. This study developed an improved method that accurately quantifies the irradiation field under TCM scans. The results suggested that organ dose could be estimated in real-time both prospectively (with the localizer information only) and retrospectively (with acquired CT data).
引用
收藏
页码:3935 / 3954
页数:20
相关论文
共 50 条
  • [31] Radiation dose reduction to the breast in thoracic CT: Comparison of bismuth shielding, organ-based tube current modulation, and use of a globally decreased tube current
    Wang, Jia
    Duan, Xinhui
    Christner, Jodie A.
    Leng, Shuai
    Yu, Lifeng
    McCollough, Cynthia H.
    MEDICAL PHYSICS, 2011, 38 (11) : 6084 - 6092
  • [32] Fetal Dose Estimates for Tube Current Modulated (TCM) and Fixed Tube Current (FTC) Abdominal/Pelvic CT Examinations of Pregnant Patients
    Hardy, A.
    Bostani, M.
    Angel, E.
    Cagnon, C.
    McNitt-Gray, M.
    MEDICAL PHYSICS, 2019, 46 (06) : E519 - E519
  • [33] Estimating fetal dose from tube current-modulated (TCM) and fixed tube current (FTC) abdominal/pelvis CT examinations
    Hardy, Anthony J.
    Angel, Erin
    Bostani, Maryam
    Cagnon, Chris
    McNitt-Gray, Michael
    MEDICAL PHYSICS, 2019, 46 (06) : 2729 - 2743
  • [34] Organ dose and scattering dose for CT coronary angiography and calcium scoring using automatic tube current modulation
    Chan, S. W.
    Ho, Y. J.
    Tyan, Y. S.
    Tsai, H. Y.
    RADIATION MEASUREMENTS, 2013, 56 : 333 - 337
  • [35] Comparison of Measured and Estimated CT Organ Doses for Modulated and Fixed Tube Current: A Human Cadaver Study
    Padole, Atul
    Khawaja, Ranish Deedar Ali
    Otrakji, Alexi
    Zhang, Da
    Liu, Bob
    Xu, X. George
    Kalra, Mannudeep K.
    ACADEMIC RADIOLOGY, 2016, 23 (05) : 634 - 642
  • [36] Estimating organ doses from tube current modulated CT examinations using a generalized linear model
    Bostani, Maryam
    McMillan, Kyle
    Lu, Peiyun
    Kim, Grace Hyun J.
    Cody, Dianna
    Arbique, Gary
    Greenberg, S. Bruce
    DeMarco, John J.
    Cagnon, Chris H.
    McNitt-Gray, Michael F.
    MEDICAL PHYSICS, 2017, 44 (04) : 1500 - 1513
  • [37] Organ Dose Estimation for CT Localizer Images
    Hoye, J.
    Zhang, Y.
    Fu, W.
    Abadi, E.
    Ria, F.
    Kapadia, A.
    Segars, P.
    Samei, E.
    MEDICAL PHYSICS, 2017, 44 (06) : 3301 - 3301
  • [38] Effect of Localizer Radiography Projection on Organ Dose at Chest CT with Automatic Tube Current Modulation
    Saltybaeva, Natalia
    Krauss, Andreas
    Alkadhi, Hatem
    RADIOLOGY, 2017, 282 (03) : 842 - 849
  • [39] Measurement of Basal Neurotransmitter Levels Using Convolution-Based Nonfaradaic Current Removal
    Johnson, Justin A.
    Rodeberg, Nathan T.
    Wightman, R. Mark
    ANALYTICAL CHEMISTRY, 2018, 90 (12) : 7181 - 7189
  • [40] Extraction of tube current values from DICOM CT images for patient dose estimation
    Lin, Pei-Jan Paul
    Kubo, Takeshi
    Krishnapillai, Rajeev
    MEDICAL PHYSICS, 2010, 37 (06) : 2951 - 2955