Convolution-based estimation of organ dose in tube current modulated CT

被引:23
|
作者
Tian, Xiaoyu [1 ,2 ]
Segars, W. Paul [2 ,3 ,4 ]
Dixon, Robert L. [5 ]
Samei, Ehsan [1 ,2 ,3 ,4 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27705 USA
[2] Duke Univ, Carl E Ravin Adv Imaging Labs, Durham, NC 27705 USA
[3] Duke Univ, Dept Radiol, Durham, NC 27705 USA
[4] Duke Univ, Med Phys Grad Program, Durham, NC 27705 USA
[5] Wake Forest Univ, Bowman Gray Sch Med, Dept Radiol, Winston Salem, NC 27103 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 10期
关键词
CT; computed tomography; Monte Carlo; organ dose; tube current modulation; patient specific; COMPUTATIONAL PHANTOMS; COMPUTED-TOMOGRAPHY; PEDIATRIC CHEST; OPTIMIZATION;
D O I
10.1088/0031-9155/61/10/3935
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Estimating organ dose for clinical patients requires accurate modeling of the patient anatomy and the dose field of the CT exam. The modeling of patient anatomy can be achieved using a library of representative computational phantoms (Samei et al 2014 Pediatr. Radiol. 44 460-7). The modeling of the dose field can be challenging for CT exams performed with a tube current modulation (TCM) technique. The purpose of this work was to effectively model the dose field for TCM exams using a convolution-based method. A framework was further proposed for prospective and retrospective organ dose estimation in clinical practice. The study included 60 adult patients (age range: 18-70 years, weight range: 60-180 kg). Patient-specific computational phantoms were generated based on patient CT image datasets. A previously validated Monte Carlo simulation program was used to model a clinical CT scanner (SOMATOM Definition Flash, Siemens Healthcare, Forchheim, Germany). A practical strategy was developed to achieve real-time organ dose estimation for a given clinical patient. CTDIvol-normalized organ dose coefficients (h(Organ)) under constant tube current were estimated and modeled as a function of patient size. Each clinical patient in the library was optimally matched to another computational phantom to obtain a representation of organ location/distribution. The patient organ distribution was convolved with a dose distribution profile to generate (CTDIvol)(organ, convolution) values that quantified the regional dose field for each organ. The organ dose was estimated by multiplying (CTDIvol)(organ,) (convolution) with the organ dose coefficients (h(Organ)). To validate the accuracy of this dose estimation technique, the organ dose of the original clinical patient was estimated using Monte Carlo program with TCM profiles explicitly modeled. The discrepancy between the estimated organ dose and dose simulated using TCM Monte Carlo program was quantified. We further compared the convolution-based organ dose estimation method with two other strategies with different approaches of quantifying the irradiation field. The proposed convolution-based estimation method showed good accuracy with the organ dose simulated using the TCM Monte Carlo simulation. The average percentage error (normalized by CTDIvol) was generally within 10% across all organs and modulation profiles, except for organs located in the pelvic and shoulder regions. This study developed an improved method that accurately quantifies the irradiation field under TCM scans. The results suggested that organ dose could be estimated in real-time both prospectively (with the localizer information only) and retrospectively (with acquired CT data).
引用
收藏
页码:3935 / 3954
页数:20
相关论文
共 50 条
  • [21] Personalized, Scout-Based Dose Estimation for Prospective Optimization of CT Tube Current Modulation
    Medrano, Maria
    Wang, Sen
    Imran, Abdullah-Al-Zubaer
    Stevens, Grant
    Tse, Justin Ruey
    Wang, Adam
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925
  • [22] Image quality and age-specific dose estimation in head and chest CT examinations with organ-based tube-current modulation
    Yamauchi-Kawaura, C.
    Yamauchi, M.
    Imai, K.
    Ikeda, M.
    Aoyama, T.
    RADIATION PROTECTION DOSIMETRY, 2013, 157 (02) : 193 - 205
  • [23] Multiscale Convolution-Based Efficient Channel Estimation Techniques for OFDM Systems
    Kwon, Nahyeon
    Yoon, Bora
    Kim, Junghyun
    ELECTRONICS, 2025, 14 (02):
  • [24] Tissue equivalent phantoms for the evaluation of tube current modulated CT dose and image quality
    Fisher, R.
    Hintenlang, D.
    MEDICAL PHYSICS, 2006, 33 (06) : 2002 - 2002
  • [25] Dose Trends in Tube-Current Modulated Multi-Detector CT Imaging
    Fisher, R.
    Hintenlang, D.
    Winslow, J.
    Moloney, W.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [26] Convolution-based time-domain simulation for fluidelastic instability in tube arrays
    Zhang, Mingjie
    oiseth, Ole
    NONLINEAR DYNAMICS, 2021, 104 (04) : 4063 - 4081
  • [27] Tensor Convolution-Based Aggregated Flexibility Estimation in Active Distribution Systems
    Chrysostomou, Demetris
    Torres, Jose Luis Rueda
    Cremer, Jochen Lorenz
    IEEE TRANSACTIONS ON SMART GRID, 2025, 16 (01) : 87 - 100
  • [28] Prospective Optimization of CT under Tube Current Modulation: I. Organ Dose
    Tian, Xiaoyu
    Li, Xiang
    Segars, W. Paul
    Frush, Donald P.
    Samei, Ehsan
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [29] Characterization of radiation dose from tube current modulated CT examinations with considerations of both patient size and variable tube current
    Li, Xinhua
    Yang, Kai
    Liu, Bob
    MEDICAL PHYSICS, 2017, 44 (10) : 5413 - 5422
  • [30] Convolution-based time-domain simulation for fluidelastic instability in tube arrays
    Mingjie Zhang
    Ole Øiseth
    Nonlinear Dynamics, 2021, 104 : 4063 - 4081