Convolution-based estimation of organ dose in tube current modulated CT

被引:23
|
作者
Tian, Xiaoyu [1 ,2 ]
Segars, W. Paul [2 ,3 ,4 ]
Dixon, Robert L. [5 ]
Samei, Ehsan [1 ,2 ,3 ,4 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27705 USA
[2] Duke Univ, Carl E Ravin Adv Imaging Labs, Durham, NC 27705 USA
[3] Duke Univ, Dept Radiol, Durham, NC 27705 USA
[4] Duke Univ, Med Phys Grad Program, Durham, NC 27705 USA
[5] Wake Forest Univ, Bowman Gray Sch Med, Dept Radiol, Winston Salem, NC 27103 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 10期
关键词
CT; computed tomography; Monte Carlo; organ dose; tube current modulation; patient specific; COMPUTATIONAL PHANTOMS; COMPUTED-TOMOGRAPHY; PEDIATRIC CHEST; OPTIMIZATION;
D O I
10.1088/0031-9155/61/10/3935
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Estimating organ dose for clinical patients requires accurate modeling of the patient anatomy and the dose field of the CT exam. The modeling of patient anatomy can be achieved using a library of representative computational phantoms (Samei et al 2014 Pediatr. Radiol. 44 460-7). The modeling of the dose field can be challenging for CT exams performed with a tube current modulation (TCM) technique. The purpose of this work was to effectively model the dose field for TCM exams using a convolution-based method. A framework was further proposed for prospective and retrospective organ dose estimation in clinical practice. The study included 60 adult patients (age range: 18-70 years, weight range: 60-180 kg). Patient-specific computational phantoms were generated based on patient CT image datasets. A previously validated Monte Carlo simulation program was used to model a clinical CT scanner (SOMATOM Definition Flash, Siemens Healthcare, Forchheim, Germany). A practical strategy was developed to achieve real-time organ dose estimation for a given clinical patient. CTDIvol-normalized organ dose coefficients (h(Organ)) under constant tube current were estimated and modeled as a function of patient size. Each clinical patient in the library was optimally matched to another computational phantom to obtain a representation of organ location/distribution. The patient organ distribution was convolved with a dose distribution profile to generate (CTDIvol)(organ, convolution) values that quantified the regional dose field for each organ. The organ dose was estimated by multiplying (CTDIvol)(organ,) (convolution) with the organ dose coefficients (h(Organ)). To validate the accuracy of this dose estimation technique, the organ dose of the original clinical patient was estimated using Monte Carlo program with TCM profiles explicitly modeled. The discrepancy between the estimated organ dose and dose simulated using TCM Monte Carlo program was quantified. We further compared the convolution-based organ dose estimation method with two other strategies with different approaches of quantifying the irradiation field. The proposed convolution-based estimation method showed good accuracy with the organ dose simulated using the TCM Monte Carlo simulation. The average percentage error (normalized by CTDIvol) was generally within 10% across all organs and modulation profiles, except for organs located in the pelvic and shoulder regions. This study developed an improved method that accurately quantifies the irradiation field under TCM scans. The results suggested that organ dose could be estimated in real-time both prospectively (with the localizer information only) and retrospectively (with acquired CT data).
引用
收藏
页码:3935 / 3954
页数:20
相关论文
共 50 条
  • [1] Convolution-based Estimation of Organ Dose in Tube Current Modulated CT
    Tian, Xiaoyu
    Segars, W. Paul
    Dixon, R. L.
    Samei, Ehsan
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [2] Uncertainties in Convolution-Based Organ Dose Estimation in TubeCurrent Modulated CT
    Fu, W.
    Choudhury, K.
    Kapadia, A.
    Segars, P.
    Samei, E.
    MEDICAL PHYSICS, 2017, 44 (06) : 3301 - 3301
  • [3] Estimation of breast dose reduction potential for organ-based tube current modulated CT with wide dose reduction arc
    Fu, Wanyi
    Sturgeon, Gregory M.
    Agasthya, Greeshma
    Segars, W. Paul
    Kapadia, Anuj J.
    Samei, Ehsan
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [4] Estimation of Breast Dose Saving Potential Using a Breast Positioning Technique for Organ-based Tube Current Modulated CT
    Fu, Wanyi
    Tian, Xiaoyu
    Sturgeon, Gregory
    Agasthya, Greeshma
    Segars, William Paul
    Goodsitt, Mitchell M.
    Kazerooni, Ella A.
    Samei, Ehsan
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [5] Prospective estimation of organ dose in CT under tube current modulation
    Tian, Xiaoyu
    Li, Xiang
    Segars, W. Paul
    Frush, Donald P.
    Samei, Ehsan
    MEDICAL PHYSICS, 2015, 42 (04) : 1575 - 1585
  • [6] Breast dose reduction with organ-based, wide-angle tube current modulated CT
    Fu W.
    Sturgeon G.M.
    Agasthya G.
    Segars W.P.
    Kapadia A.J.
    Samei E.
    Fu, Wanyi (wanyi.fu@duke.edu), 1600, SPIE (04):
  • [7] Organ dose conversion coefficients for tube current modulated CT protocols for an adult population
    Fu, Wanyi
    Tian, Xiaoyu
    Sahbaee, Pooyan
    Zhang, Yakun
    Segars, William Paul
    Samei, Ehsan
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [8] Estimating Organ Dose From CT Scans Performed with Tube Current Modulated Scans
    Khatonabadi, M.
    Chu, G.
    Oria, D.
    Cagnon, C.
    DeMarco, J.
    McNitt-Gray, M.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [9] The feasibility of a regional CTDIvol to estimate organ dose from tube current modulated CT exams
    Khatonabadi, Maryam
    Kim, Hyun J.
    Lu, Peiyun
    McMillan, Kyle L.
    Cagnon, Chris H.
    DeMarco, John J.
    McNitt-Gray, Michael F.
    MEDICAL PHYSICS, 2013, 40 (05)
  • [10] Attenuation-based size metric for estimating organ dose to patients undergoing tube current modulated CT exams
    Bostani, Maryam
    McMillan, Kyle
    Lu, Peiyun
    Kim, Hyun J.
    Cagnon, Chris H.
    DeMarco, John J.
    McNitt-Gray, Michael F.
    MEDICAL PHYSICS, 2015, 42 (02) : 958 - 968