A performance evaluation of the open tube diffusion sampler (Palmes sampler) for monitoring nitrogen dioxide

被引:0
|
作者
De Santis, F [1 ]
Fino, A [1 ]
Tiwari, S [1 ]
Vazzana, C [1 ]
Allegrini, I [1 ]
机构
[1] CNR, Ist Inquinamento Atmosfer, Area Ricerca Roma, Rome, Italy
来源
AIR POLLUTION VIII | 2000年 / 8卷
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The Palmes sampler is largely used to carry out indicative measurements for NO2 as considered in EU legislation (Daughter Directive 1999/30/EC). In order to comply with the quality objectives set out in this directive it is important that the limits of this technique are fully appreciated. The sampler was tested in a chamber study and in field trials. Experiments were carried out to study the effect of wind turbulence, the stability of the NO2-TEA adduct and the self-consistency of the method. The results of these experiments demonstrated underestimation in comparison to chemiluminescence probably due to photodegradation of the NO2-TEA adduct and/or incomplete extraction of nitrite.
引用
收藏
页码:421 / 429
页数:9
相关论文
共 50 条
  • [41] Field testing of a new flow-through directional passive air sampler applied to monitoring ambient nitrogen dioxide
    Lin, Chun
    McKenna, Paul
    Timmis, Roger
    Jones, Kevin C.
    JOURNAL OF ENVIRONMENTAL MONITORING, 2010, 12 (07): : 1430 - 1436
  • [43] Measurement of ambient concentration of NO2 in Delhi using passive diffusion tube sampler
    Varshney, CK
    Singh, AP
    CURRENT SCIENCE, 2002, 83 (06): : 731 - 735
  • [44] Gas-diffusion-based passive sampler for ammonia monitoring in marine waters
    Sraj, Lenka O'Connor
    Almeida, M. Ines G. S.
    Bassett, Chelsea
    McKelvie, Ian D.
    Kolev, Spas D.
    TALANTA, 2018, 181 : 52 - 56
  • [45] A diffusion tube sampler for the determination of acetic acid and formic acid vapours in museum cabinets
    Gibson, LT
    Cooksey, BG
    Littlejohn, D
    Tennent, NH
    ANALYTICA CHIMICA ACTA, 1997, 341 (01) : 11 - 19
  • [46] Performance evaluation of disposable inhalable aerosol sampler at a copper electrorefinery
    Lee, Eun Gyung
    Grimson, Peter J.
    Chisholm, William P.
    Kashon, Michael L.
    He, Xinjian
    L'Orange, Christian
    Volckens, John
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2019, 16 (03) : 250 - 257
  • [47] Validation tests of a new high uptake rate passive sampler for nitrogen dioxide measurements
    Piechocki-Minguy, A
    Plaisance, H
    Garcia-Fouqué, S
    Galloo, JC
    Guillermo, R
    ENVIRONMENTAL TECHNOLOGY, 2003, 24 (12) : 1527 - 1535
  • [48] A diffusion denuder sampler for routine monitoring of airborne fine particulate material.
    Ding, Y
    Pang, Y
    Eatough, DJ
    Eatough, NL
    Tanner, RL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 215 : U582 - U582
  • [49] Evaluation of a simple, inexpensive dialysis sampler for small diameter monitoring wells
    Harter, T
    Talozi, S
    GROUND WATER MONITORING AND REMEDIATION, 2004, 24 (04): : 97 - 105
  • [50] Performance optimisation of a passive sampler for monitoring hydrophobic organic pollutants in water
    Vrana, B
    Mills, G
    Greenwood, R
    Knutsson, J
    Svenssone, K
    Morrison, G
    JOURNAL OF ENVIRONMENTAL MONITORING, 2005, 7 (06): : 612 - 620