Simultaneous voltammetric determination of tramadol and acetaminophen using carbon nanoparticles modified glassy carbon electrode

被引:142
|
作者
Ghorbani-Bidkorbeh, Fatemeh [1 ,2 ]
Shahrokhian, Saeed [1 ,3 ]
Mohammadi, Ali [4 ]
Dinarvand, Rassoul [2 ,5 ]
机构
[1] Sharif Univ Technol, Dept Chem, Tehran 111559516, Iran
[2] Univ Tehran Med Sci, Fac Pharm, Dept Pharmaceut, Tehran, Iran
[3] Sharif Univ Technol, Inst Nanosci & Technol, Tehran 111559516, Iran
[4] Univ Tehran Med Sci, Fac Pharm, Dept Drug & Food Control, Tehran, Iran
[5] Univ Tehran Med Sci, Fac Pharm, Nanotechnol Res Ctr, Tehran, Iran
关键词
Acetaminophen; Tramadol; Carbon nanoparticles; Modified electrode; Voltammetry; HUMAN PLASMA; SPECTROPHOTOMETRIC DETERMINATION; CAPILLARY-ELECTROPHORESIS; FILM ELECTRODES; PARACETAMOL; CHROMATOGRAPHY; NANOTUBES; GRAPHITE;
D O I
10.1016/j.electacta.2009.12.052
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A sensitive and selective electrochemical sensor was fabricated via the drop-casting of carbon nanoparticles (CNPs) suspension onto a glassy carbon electrode (GCE). The application of this sensor was investigated in simultaneous determination of acetaminophen (ACE) and tramadol (TRA) drugs in pharmaceutical dosage form and ACE determination in human plasma. In order to study the electrochemical behaviors of the drugs, cyclic and differential pulse voltammetric studies of ACE and IRA were carried out at the surfaces of the modified GCE (MGCE) and the bare GCE. The dependence of peak currents and potentials on pH, concentration and the potential scan rate were investigated for these compounds at the surface of MGCE. Atomic force microscopy (AFM) was used for the characterization of the film modifier and its morphology on the surface of GCE. The results of the electrochemical investigations showed that CNPs, via a thin layer model based on the diffusion within a porous layer, enhanced the electroactive surface area and caused a remarkable increase in the peak currents. The thin layer of the modifier showed a catalytic effect and accelerated the rate of the electron transfer process. Application of the MGCE resulted in a sensitivity enhancement and a considerable decrease in the anodic overpotential, leading to negative shifts in peak potentials. An optimum electrochemical response was obtained for the sensor in the buffered solution of pH 7.0 and using 2 mu L CNPs suspension cast on the surface of GCE. Using differential pulse voltammetry, the prepared sensor showed good sensitivity and selectivity for the determination of ACE and TRA in wide linear ranges of 0.1-100 and 10-1000 mu M, respectively. The resulted detection limits for ACE and IRA was 0.05 and 1 mu M, respectively. The CNPs modified GCE was successfully applied for ACE and TRA determinations in pharmaceutical dosage forms and also for the determination of ACE in human plasma. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2752 / 2759
页数:8
相关论文
共 50 条
  • [41] Voltammetric determination of dopamine using modified glassy carbon electrode by electrografting of catechol
    Pourghobadi, Zeinab
    Neamatollahi, Davood
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2017, 82 (09) : 1053 - 1061
  • [43] Voltammetric determination of disinfectants at multiwalled carbon nanotube modified glassy carbon electrode
    I. Baranowska
    K. Bijak
    Journal of Analytical Chemistry, 2013, 68 : 891 - 895
  • [44] Simultaneous voltammetric sensing of acetaminophen, epinephrine and melatonin using a carbon paste electrode modified with zinc ferrite nanoparticles
    Nahid Tavakkoli
    Nasrin Soltani
    Faezeh Shahdost-fard
    Mahbobeh Ramezani
    Hossein Salavati
    Mohammad Reza Jalali
    Microchimica Acta, 2018, 185
  • [45] Simultaneous voltammetric sensing of acetaminophen, epinephrine and melatonin using a carbon paste electrode modified with zinc ferrite nanoparticles
    Tavakkoli, Nahid
    Soltani, Nasrin
    Shahdost-fard, Faezeh
    Ramezani, Mahbobeh
    Salavati, Hossein
    Jalali, Mohammad Reza
    MICROCHIMICA ACTA, 2018, 185 (10)
  • [46] Simultaneous Voltammetric Determination of Theophylline and Guaifenesin Using a Multiwalled Carbon Nanotube-Ionic Liquid Modified Glassy Carbon Electrode
    Gholivand, Mohammad Bagher
    Khodadadian, Mehdi
    ELECTROANALYSIS, 2014, 26 (09) : 1975 - 1983
  • [47] A Sensitive Simultaneous Determination of Acetaminophen and Indomethacin at Multi-walled Carbon Nanotubes Modified Glassy Carbon Electrode
    Babaei, Ali
    Farshbaf, Mojtaba
    Afrasiabi, Mohammad
    Dehdashti, Aliyeh
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2012, 4 (06): : 564 - 578
  • [48] A Sensor for Simultaneous Determination of Acetaminophen and Codeine at Glassy Carbon Electrode Modified with Multi-Walled Carbon Nanotubes
    Babaei, Ali
    Dehdashti, Aliyeh
    Afrasiabi, Mohammad
    Babazadeh, Mitra
    Farshbaf, Mojtaba
    Bamdad, Farzad
    SENSOR LETTERS, 2012, 10 (3-4) : 1039 - 1046
  • [49] Simultaneous voltammetric determination of dihydroxybenzene isomers at single-walled carbon nanohorn modified glassy carbon electrode
    Zhu, Shuyun
    Gao, Wenyue
    Zhang, Ling
    Zhao, Jianming
    Xu, Guobao
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 198 : 388 - 394
  • [50] Simultaneous voltammetric determination of tramadol and paracetamol exploiting glassy carbon electrode modified with FeNi3 nanoalloy in biological and pharmaceutical media
    Hajmalek, Saeed
    Jahani, Shohreh
    Foroughi, Mohammad Mehdi
    CHEMISTRYSELECT, 2021, 6 (33): : 8797 - 8808