Reduced graphene oxide supported MXene based metal oxide ternary composite electrodes for non-enzymatic glucose sensor applications

被引:15
|
作者
Gopal, Tamil Selvi [1 ]
Alzahrani, Khalid E. [2 ,3 ]
Assaifan, Abdulaziz K. [2 ]
Albrithen, Hamad [2 ,3 ]
Alodhayb, Abdullah [2 ,3 ]
Muthuramamoorthy, Muthumareeswaran [2 ]
Pandiaraj, Saravanan [4 ]
Grace, Andrews Nirmala [1 ]
机构
[1] Vellore Inst Technol, Ctr Nanotechnol Res, Vellore, Tamil Nadu, India
[2] King Saud Univ, King Abdullah Inst Nanotechnol, Biol & Environm Sensing Res Unit, POB 2455, Riyadh 11451, Saudi Arabia
[3] King Saud Univ, Coll Sci, Dept Phys & Astron, Riyadh 11451, Saudi Arabia
[4] King Saud Univ, Dept Selfdev Skills, CFY Deanship, Riyadh, Saudi Arabia
关键词
SUPERCAPACITOR; ARCHITECTURES; ARRAYS;
D O I
10.1038/s41598-022-24700-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Diagnosis and monitoring of glucose level in human blood has become a prime necessity to avoid health risk and to cater this, a sensor's performance with wide linearity range and high sensitivity is required. This work reports the use of ternary composite viz. MG-Cu2O (rGO supported MXene sheet with Cu2O) for non-enzymatic sensing of glucose. It has been prepared by co-precipitation method and characterized with X-ray powder diffraction, Ultraviolet-visible absorption spectroscopy (UV-Vis), Raman spectroscopy, Field emission scanning electron microscopy, High resolution transmission electron microscopy and Selected area diffraction. These analyses show a cubic structure with spherical shaped Cu2O grown on the MG sheet. Further, the electrocatalytic activity was carried out with MG-Cu2O sensing element by cyclic voltammetry and chronoamperometry technique and compared with M-Cu2O (MXene with Cu2O) composite without graphene oxide. Of these, MG-Cu2O composite was having the high defect density with lower crystalline size of Cu2O, which might enhance the conductivity thereby increasing the electrocatalytic activity towards the oxidation of glucose as compared to M-Cu2O. The prepared MG-Cu2O composite shows a sensitivity of 126.6 mu AmM-1 cm(-2) with a wide linear range of 0.01to 30 mM, good selectivity, good stability over 30 days and shows a low Relative Standard Deviation (RSD) of 1.7% value towards the sensing of glucose level in human serum. Thus, the aforementioned finding indicates that the prepared sensing electrode is a well suitable candidate for the sensing of glucose level for real time applications.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Development of Non-enzymatic Electrochemical Glucose Sensor Based on Graphene Oxide Nanoribbon - Gold Nanoparticle Hybrid
    Ismail, Nur Syakimah
    Le, Quynh Hoa
    Yoshikawa, Hiroyuki
    Saito, Masato
    Tamiya, Eiichi
    ELECTROCHIMICA ACTA, 2014, 146 : 98 - 105
  • [32] A non-enzymatic electrochemical sensor based on zinc oxide/reduced graphene oxide (ZnO/rGO) nanocomposite for effective detection of urea
    Aparna, S. M.
    Rakhi, R. B.
    MATERIALS SCIENCE AND ENGINEERING B-ADVANCED FUNCTIONAL SOLID-STATE MATERIALS, 2025, 312
  • [33] MWCNT-ruthenium oxide composite paste electrode as non-enzymatic glucose sensor
    Tehrani, Ramin M. A.
    Ab Ghani, Sulaiman
    BIOSENSORS & BIOELECTRONICS, 2012, 38 (01): : 278 - 283
  • [34] Sensitive Non-Enzymatic Glucose Electrochemical Sensor Based on Electrochemically Synthesized PANI/Bimetallic Oxide Composite
    Khan, Anish
    Khan, Aftab Aslam Parwaz
    Marwani, Hadi M.
    Alotaibi, Maha Moteb
    Asiri, Abdullah M.
    Manikandan, Ayyar
    Siengchin, Suchart
    Rangappa, Sanjay Mavinkere
    POLYMERS, 2022, 14 (15)
  • [35] Multi-dimensional Ag/NiO/reduced graphene oxide nanostructures for a highly sensitive non-enzymatic glucose sensor
    Yen-Linh Thi Ngo
    Le Thuy Hoa
    Chung, Jin Suk
    Hur, Seung Huyn
    JOURNAL OF ALLOYS AND COMPOUNDS, 2017, 712 : 742 - 751
  • [36] Non-enzymatic glucose sensor fabricated by CoFe2O4 nanosheets grown on Reduced Graphene Oxide
    Dong, Min
    Hu, Hongli
    Ding, Shujiang
    Duan, Yujie
    Cui, Chenhui
    MATERIALS TECHNOLOGY, 2022, 37 (14) : 3184 - 3193
  • [37] Highly sensitive non-enzymatic glucose sensor based on copper oxide nanorods
    Haneen Ali Jasim
    Osama Abdul Azeez Dakhil
    Journal of Nanoparticle Research, 2022, 24
  • [38] A sensitive non-enzymatic electrochemical glucose sensor based on a ZnO/Co3O4/reduced graphene oxide nanocomposite
    Hussein, Beshir A.
    Tsegaye, Abebaw A.
    Shifera, Getabalew
    M. Taddesse, Abi
    SENSORS & DIAGNOSTICS, 2023, 2 (02): : 347 - 360
  • [39] Highly sensitive non-enzymatic glucose sensor based on copper oxide nanorods
    Jasim, Haneen Ali
    Dakhil, Osama Abdul Azeez
    JOURNAL OF NANOPARTICLE RESEARCH, 2022, 24 (11)
  • [40] Copper/reduced graphene oxide film modified electrode for non-enzymatic glucose sensing application
    Phetsang, Sopit
    Kidkhunthod, Pinit
    Chanlek, Narong
    Jakmunee, Jaroon
    Mungkornasawakul, Pitchaya
    Ounnunkad, Kontad
    SCIENTIFIC REPORTS, 2021, 11 (01)