Reduced graphene oxide supported MXene based metal oxide ternary composite electrodes for non-enzymatic glucose sensor applications

被引:15
|
作者
Gopal, Tamil Selvi [1 ]
Alzahrani, Khalid E. [2 ,3 ]
Assaifan, Abdulaziz K. [2 ]
Albrithen, Hamad [2 ,3 ]
Alodhayb, Abdullah [2 ,3 ]
Muthuramamoorthy, Muthumareeswaran [2 ]
Pandiaraj, Saravanan [4 ]
Grace, Andrews Nirmala [1 ]
机构
[1] Vellore Inst Technol, Ctr Nanotechnol Res, Vellore, Tamil Nadu, India
[2] King Saud Univ, King Abdullah Inst Nanotechnol, Biol & Environm Sensing Res Unit, POB 2455, Riyadh 11451, Saudi Arabia
[3] King Saud Univ, Coll Sci, Dept Phys & Astron, Riyadh 11451, Saudi Arabia
[4] King Saud Univ, Dept Selfdev Skills, CFY Deanship, Riyadh, Saudi Arabia
关键词
SUPERCAPACITOR; ARCHITECTURES; ARRAYS;
D O I
10.1038/s41598-022-24700-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Diagnosis and monitoring of glucose level in human blood has become a prime necessity to avoid health risk and to cater this, a sensor's performance with wide linearity range and high sensitivity is required. This work reports the use of ternary composite viz. MG-Cu2O (rGO supported MXene sheet with Cu2O) for non-enzymatic sensing of glucose. It has been prepared by co-precipitation method and characterized with X-ray powder diffraction, Ultraviolet-visible absorption spectroscopy (UV-Vis), Raman spectroscopy, Field emission scanning electron microscopy, High resolution transmission electron microscopy and Selected area diffraction. These analyses show a cubic structure with spherical shaped Cu2O grown on the MG sheet. Further, the electrocatalytic activity was carried out with MG-Cu2O sensing element by cyclic voltammetry and chronoamperometry technique and compared with M-Cu2O (MXene with Cu2O) composite without graphene oxide. Of these, MG-Cu2O composite was having the high defect density with lower crystalline size of Cu2O, which might enhance the conductivity thereby increasing the electrocatalytic activity towards the oxidation of glucose as compared to M-Cu2O. The prepared MG-Cu2O composite shows a sensitivity of 126.6 mu AmM-1 cm(-2) with a wide linear range of 0.01to 30 mM, good selectivity, good stability over 30 days and shows a low Relative Standard Deviation (RSD) of 1.7% value towards the sensing of glucose level in human serum. Thus, the aforementioned finding indicates that the prepared sensing electrode is a well suitable candidate for the sensing of glucose level for real time applications.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Fabrication and characterization of graphite oxide - nanoparticle composite based field effect transistors for non-enzymatic glucose sensor applications
    Said, Khadija
    Ayesh, Ahmad I.
    Qamhieh, Naser N.
    Awwad, Falah
    Mahmoud, Saleh T.
    Hisaindee, Soleiman
    JOURNAL OF ALLOYS AND COMPOUNDS, 2017, 694 : 1061 - 1066
  • [22] Novel alkaline-reduced cuprous oxide/graphene nanocomposites for non-enzymatic amperometric glucose sensor application
    Yazid, Siti Nur Akmar Mohd
    Isa, Illyas Md
    Hashim, Norhayati
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 68 : 465 - 473
  • [24] Nickel-functionalized reduced graphene oxide with polyaniline for non-enzymatic glucose sensing
    Bing Zhang
    Yu He
    Bingqian Liu
    Dianping Tang
    Microchimica Acta, 2015, 182 : 625 - 631
  • [25] Nickel-functionalized reduced graphene oxide with polyaniline for non-enzymatic glucose sensing
    Zhang, Bing
    He, Yu
    Liu, Bingqian
    Tang, Dianping
    MICROCHIMICA ACTA, 2015, 182 (3-4) : 625 - 631
  • [26] Metal oxide based non-enzymatic electrochemical sensors for glucose detection
    Dong, Qiuchen
    Ryu, Heejeong
    Lei, Yu
    ELECTROCHIMICA ACTA, 2021, 370
  • [27] Well-dispersed palladium nanoparticles on graphene oxide as a non-enzymatic glucose sensor
    Wang, Qiyu
    Cui, Xiaoqiang
    Chen, Jianli
    Zheng, Xianliang
    Liu, Chang
    Xue, Tianyu
    Wang, Haitao
    Jin, Zhao
    Qiao, Liang
    Zheng, Weitao
    RSC ADVANCES, 2012, 2 (15): : 6245 - 6249
  • [28] Ultrasensitive Non-Enzymatic Glucose Sensors Based on Hybrid Reduced Graphene Oxide and Carbonized Silk Fabric Electrodes Decorated with Cu Nanoflowers
    Wei, Luo
    Li, Ji-Hui
    Chen, Chao
    Lv, Qian
    Lv, Ruitao
    Ma, Liqiang
    Shen, Wanci
    Kang, Feiyu
    Huang, Zheng-Hong
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (12)
  • [29] MXene-based composite electrodes for efficient electrochemical sensing of glucose by non-enzymatic method
    Gopal, Tamil Selvi
    Jeong, Soon Kwan
    Alrebdi, Tahani A.
    Pandiaraj, Saravanan
    Alodhayb, Abdullah
    Muthuramamoorthy, Muthumareeswaran
    Grace, Andrews Nirmala
    MATERIALS TODAY CHEMISTRY, 2022, 24
  • [30] Highly sensitive non-enzymatic glucose sensor based on Pt nanoparticle decorated graphene oxide hydrogel
    Hoa, Le Thuy
    Sun, Kang Gyu
    Hur, Seung Hyun
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 210 : 618 - 623