Usefulness of remote monitoring for the early detection of back-up mode in implantable cardioverter defibrillators

被引:2
|
作者
Guedon-Moreau, Laurence [1 ,2 ]
Finat, Loic [1 ]
Klein, Cedric [1 ]
Kouakam, Claude [1 ]
Marquie, Christelle [1 ]
Klug, Didier [1 ,2 ]
Potelle, Charlotte [1 ]
Ninni, Sandro [1 ,2 ]
Brigadeau, Francois [1 ]
Mirabel, Xavier [3 ]
Lacroix, Dominique [1 ,2 ]
机构
[1] Lille Univ Hosp, Dept Cardiovasc Med, Heart & Lung Inst, F-59037 Lille, France
[2] Lille Univ, Fac Med, F-59045 Lille, France
[3] Ctr Oscar Lambret, Ctr Canc, F-59000 Lille, France
关键词
Remote monitoring; Implantable cardioverter defibrillator; Telemedicine; Back-up mode; Radiotherapy; HEART-FAILURE PATIENTS; DEVICE FOLLOW-UP; MANAGEMENT; ICD; TRIAL; TIME; LEAD;
D O I
10.1016/j.acvd.2020.11.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. - Reversion of an implantable cardioverter defibrillator (ICD) to back-up mode degrades the operating capabilities of the device, puts patients at risk and requires rapid intervention by a manufacturer's technician. Aim. - To illustrate the usefulness of remote monitoring of ICDs for the early detection of reversion to back-up mode. Methods. - In our centre, all patients implanted with an ICD, with or without resynchronisation, were offered remote monitoring as soon as the technology became available. Alerts triggered by the remote monitoring system were included prospectively in a register. During a mean follow-up of 5.7 +/- 1.3 years, a total of 1594 patients with an ICD (441 with resynchronisation function) followed with remote monitoring were included in the register. Results. - Among 15,874 alerts, only 10 were related to a reversion to back-up mode. Among those, seven reversions were caused by radiotherapy, two were fake events and one was caused by magnetic resonance imaging. Except for the two fake events, the eight other patients had an emergency admission for the resetting and reprogramming of their ICD. None of the reversion to back-up mode alerts was followed by a clinical alert (i.e. a shock alert) before the ICD problem was resolved. Conclusions. - Reversion to back-up mode is a very rare event, accounting for 0.06% of total alerts; remote monitoring facilitates the early detection of this critical event to resolve the problem faster than the next scheduled follow-up. Remote monitoring can prevent serious dam-age to the patient and avoids systematic ambulatory control of the ICD after each radiotherapy session. (c) 2021 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:287 / 292
页数:6
相关论文
共 50 条
  • [31] Incidence of magnet mode in patients with implantable cardioverter defibrillators
    von Olshausen, Gesa
    Schorr, Johanna
    Grebmer, Christian
    Weigand, Severin
    Blazek, Patrick
    Brkic, Amir
    Friedrich, Lena
    Semmler, Verena
    Kolb, Christof
    Lennerz, Carsten
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2019, 56 (03) : 335 - 339
  • [32] Incidence of magnet mode in patients with implantable cardioverter defibrillators
    Gesa von Olshausen
    Johanna Schorr
    Christian Grebmer
    Severin Weigand
    Patrick Blažek
    Amir Brkic
    Lena Friedrich
    Verena Semmler
    Christof Kolb
    Carsten Lennerz
    Journal of Interventional Cardiac Electrophysiology, 2019, 56 : 335 - 339
  • [33] Delivering remote monitoring data to patients with implantable cardioverter-defibrillators: Does medium matter?
    Mirro, Michael
    Daley, Carly
    Wagner, Shauna
    Ghahari, Romisa Rohani
    Drouin, Michelle
    Toscos, Tammy
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2018, 41 (11): : 1526 - 1535
  • [34] The benefits of remote monitoring in long-term care for patients with implantable cardioverter-defibrillators
    Osmera, Ondrej
    Bulava, Alan
    NEUROENDOCRINOLOGY LETTERS, 2014, 35 : 40 - 48
  • [35] Remote monitoring and follow-ups of pacemakers and implantable cardioverter-defibrillators in the elderly patients
    Safarikova, I.
    Hajek, P.
    Bulava, A.
    ACTA CARDIOLOGICA, 2019, 74 (05) : 444 - 444
  • [36] Economic analysis of remote monitoring in patients with implantable cardioverter defibrillators or cardiac resynchronization therapy defibrillators in the Trento area, Italy
    Marini, Massimiliano
    Videsott, Lodovica
    Dalle Fratte, Chiara Francesca
    Francesconi, Andrea
    Bonvicini, Eleonora
    Quintarelli, Silvia
    Martin, Marta
    Guarracini, Fabrizio
    Coser, Alessio
    Benetollo, Pier Paolo
    Bonmassari, Roberto
    Boriani, Giuseppe
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [37] Usefulness of implantable cardioverter defibrillators in patients supported with ventricular assist devices
    Gkouziouta, A.
    Kogerakis, N.
    Louca, L.
    Kostopoulou, A.
    Theodorakis, G.
    Sfyrakis, P.
    Adamopoulos, S.
    EUROPEAN HEART JOURNAL, 2014, 35 : 767 - 768
  • [38] Usefulness of Implantable Cardioverter Defibrillators in Patients Supported With Ventricular Assist Devices
    Gkouziouta, A.
    Adamopoulos, S.
    Kostopoulou, A.
    Theodorakis, G.
    Sfirakis, P.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (04): : S204 - S204
  • [39] Usefulness of implantable cardioverter defibrillators in patients with left ventricular assist devices
    Gkouziouta, A.
    Adamopoulos, S.
    Leontiades, E.
    Karavolias, G.
    Manginas, A.
    Maounis, T. H.
    Livanis, E.
    Pavlides, G.
    Voudris, V.
    EUROPEAN HEART JOURNAL, 2011, 32 : 456 - 457
  • [40] Sensing and tachyarrhythmia detection problems in implantable cardioverter defibrillators
    Reiter, MJ
    Mann, DE
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1996, 7 (06) : 542 - 558