Usefulness of remote monitoring for the early detection of back-up mode in implantable cardioverter defibrillators

被引:2
|
作者
Guedon-Moreau, Laurence [1 ,2 ]
Finat, Loic [1 ]
Klein, Cedric [1 ]
Kouakam, Claude [1 ]
Marquie, Christelle [1 ]
Klug, Didier [1 ,2 ]
Potelle, Charlotte [1 ]
Ninni, Sandro [1 ,2 ]
Brigadeau, Francois [1 ]
Mirabel, Xavier [3 ]
Lacroix, Dominique [1 ,2 ]
机构
[1] Lille Univ Hosp, Dept Cardiovasc Med, Heart & Lung Inst, F-59037 Lille, France
[2] Lille Univ, Fac Med, F-59045 Lille, France
[3] Ctr Oscar Lambret, Ctr Canc, F-59000 Lille, France
关键词
Remote monitoring; Implantable cardioverter defibrillator; Telemedicine; Back-up mode; Radiotherapy; HEART-FAILURE PATIENTS; DEVICE FOLLOW-UP; MANAGEMENT; ICD; TRIAL; TIME; LEAD;
D O I
10.1016/j.acvd.2020.11.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. - Reversion of an implantable cardioverter defibrillator (ICD) to back-up mode degrades the operating capabilities of the device, puts patients at risk and requires rapid intervention by a manufacturer's technician. Aim. - To illustrate the usefulness of remote monitoring of ICDs for the early detection of reversion to back-up mode. Methods. - In our centre, all patients implanted with an ICD, with or without resynchronisation, were offered remote monitoring as soon as the technology became available. Alerts triggered by the remote monitoring system were included prospectively in a register. During a mean follow-up of 5.7 +/- 1.3 years, a total of 1594 patients with an ICD (441 with resynchronisation function) followed with remote monitoring were included in the register. Results. - Among 15,874 alerts, only 10 were related to a reversion to back-up mode. Among those, seven reversions were caused by radiotherapy, two were fake events and one was caused by magnetic resonance imaging. Except for the two fake events, the eight other patients had an emergency admission for the resetting and reprogramming of their ICD. None of the reversion to back-up mode alerts was followed by a clinical alert (i.e. a shock alert) before the ICD problem was resolved. Conclusions. - Reversion to back-up mode is a very rare event, accounting for 0.06% of total alerts; remote monitoring facilitates the early detection of this critical event to resolve the problem faster than the next scheduled follow-up. Remote monitoring can prevent serious dam-age to the patient and avoids systematic ambulatory control of the ICD after each radiotherapy session. (c) 2021 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:287 / 292
页数:6
相关论文
共 50 条
  • [21] Automatic home monitoring of implantable cardioverter defibrillators
    Nielsen, Jens Cosedis
    Kottkamp, Hans
    Zabel, Markus
    Aliot, Etienne
    Kreutzer, Ulrich
    Bauer, Alexander
    Schuchert, Andreas
    Neuser, Hans
    Schumacher, Burghard
    Schmidinger, Herwig
    Stix, Guenter
    Clementy, Jacques
    Danilovic, Dejan
    Hindricks, Gerhard
    EUROPACE, 2008, 10 (06): : 729 - 735
  • [22] AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATORS - MONITORING RESULTS
    KOCHS, M
    EGGELING, T
    OSTERSPEY, A
    HANNEKUM, A
    HOPP, HW
    HOMBACH, V
    DALICHAU, H
    HILGER, HH
    ZEITSCHRIFT FUR KARDIOLOGIE, 1987, 76 : 22 - 22
  • [23] Remote monitoring of implantable cardioverter-defibrillators Problems and implications using a telemonitoring system
    Siebermair, J.
    Clauss, S.
    Martens, E.
    Schuessler, F.
    Oversohl, N.
    Haserueck, N.
    Estner, H. L.
    Kaeaeb, S.
    Wakili, R.
    HERZ, 2015, 40 : 110 - 118
  • [24] Perception of remote monitoring in patients with implantable cardioverter-defibrillators in the Czech Republic environment
    Safarikova, I.
    Bulava, A.
    ACTA CARDIOLOGICA, 2017, 72 (05) : 589 - 589
  • [25] Advances in remote monitoring of implantable pacemakers, cardioverter defibrillators and cardiac resynchronization therapy systems
    Werner Jung
    Andreas Rillig
    Ralf Birkemeyer
    Tomislav Miljak
    Udo Meyerfeldt
    Journal of Interventional Cardiac Electrophysiology, 2008, 23 : 73 - 85
  • [26] Importance of education in the care of patients with implantable cardioverter-defibrillators with the possibility of remote monitoring
    Safarikova, I.
    Bulava, A.
    ACTA CARDIOLOGICA, 2022, 77 : 5 - 5
  • [27] Findings of remote monitoring of implantable cardioverter defibrillators during the COVID-19 pandemic
    De Larochelliere, Hugo
    Champagne, Jean
    Sarrazin, Jean-Francois
    Steinberg, Christian
    Philippon, Francois
    Roy, Karine
    Molin, Franck
    O'Hara, Gilles
    Plourde, Benoit
    Blier, Louis
    Nault, Isabelle
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2020, 43 (11): : 1366 - 1372
  • [28] Advances in remote monitoring of implantable pacemakers, cardioverter defibrillators and cardiac resynchronization therapy systems
    Jung, Werner
    Rillig, Andreas
    Birkemeyer, Ralf
    Miljak, Tomislav
    Meyerfeldt, Udo
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2008, 23 (01) : 73 - 85
  • [29] Remote monitoring of implantable cardioverter-defibrillators: financial impact for providers and benefits to patients
    Lewalter, Thorsten
    Brodherr, Turgut
    EUROPEAN HEART JOURNAL, 2015, 36 (03) : 143 - 144
  • [30] Follow-up of implantable cardioverter-defibrillators: Face-to-face or remote?
    Cavaco, Diogo
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2013, 32 (12) : 965 - 966