Usefulness of remote monitoring for the early detection of back-up mode in implantable cardioverter defibrillators

被引:2
|
作者
Guedon-Moreau, Laurence [1 ,2 ]
Finat, Loic [1 ]
Klein, Cedric [1 ]
Kouakam, Claude [1 ]
Marquie, Christelle [1 ]
Klug, Didier [1 ,2 ]
Potelle, Charlotte [1 ]
Ninni, Sandro [1 ,2 ]
Brigadeau, Francois [1 ]
Mirabel, Xavier [3 ]
Lacroix, Dominique [1 ,2 ]
机构
[1] Lille Univ Hosp, Dept Cardiovasc Med, Heart & Lung Inst, F-59037 Lille, France
[2] Lille Univ, Fac Med, F-59045 Lille, France
[3] Ctr Oscar Lambret, Ctr Canc, F-59000 Lille, France
关键词
Remote monitoring; Implantable cardioverter defibrillator; Telemedicine; Back-up mode; Radiotherapy; HEART-FAILURE PATIENTS; DEVICE FOLLOW-UP; MANAGEMENT; ICD; TRIAL; TIME; LEAD;
D O I
10.1016/j.acvd.2020.11.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. - Reversion of an implantable cardioverter defibrillator (ICD) to back-up mode degrades the operating capabilities of the device, puts patients at risk and requires rapid intervention by a manufacturer's technician. Aim. - To illustrate the usefulness of remote monitoring of ICDs for the early detection of reversion to back-up mode. Methods. - In our centre, all patients implanted with an ICD, with or without resynchronisation, were offered remote monitoring as soon as the technology became available. Alerts triggered by the remote monitoring system were included prospectively in a register. During a mean follow-up of 5.7 +/- 1.3 years, a total of 1594 patients with an ICD (441 with resynchronisation function) followed with remote monitoring were included in the register. Results. - Among 15,874 alerts, only 10 were related to a reversion to back-up mode. Among those, seven reversions were caused by radiotherapy, two were fake events and one was caused by magnetic resonance imaging. Except for the two fake events, the eight other patients had an emergency admission for the resetting and reprogramming of their ICD. None of the reversion to back-up mode alerts was followed by a clinical alert (i.e. a shock alert) before the ICD problem was resolved. Conclusions. - Reversion to back-up mode is a very rare event, accounting for 0.06% of total alerts; remote monitoring facilitates the early detection of this critical event to resolve the problem faster than the next scheduled follow-up. Remote monitoring can prevent serious dam-age to the patient and avoids systematic ambulatory control of the ICD after each radiotherapy session. (c) 2021 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:287 / 292
页数:6
相关论文
共 50 条
  • [1] Remote Monitoring of Implantable Cardioverter Defibrillators
    Dilaveris, Polychronis
    Piotrowicz, Ryszard
    HELLENIC JOURNAL OF CARDIOLOGY, 2014, 55 (01) : 1 - 3
  • [2] Remote monitoring of subcutaneous implantable cardioverter defibrillators
    De Filippo, Paolo
    Luzi, Mario
    D'Onofrio, Antonio
    Bongiorni, Maria Grazia
    Giammaria, Massimo
    Bisignani, Giovanni
    Menardi, Endrj
    Ferrari, Paola
    Bianchi, Valter
    Viani, Stefano
    Leidi, Cristina
    Lovecchio, Mariolina
    Valsecchi, Sergio
    Capucci, Alessandro
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2018, 53 (03) : 373 - 381
  • [3] Remote Interrogation and Monitoring of Implantable Cardioverter Defibrillators
    George K. Joseph
    Bruce L. Wilkoff
    Thomas Dresing
    John Burkhardt
    Yaariv Khaykin
    Journal of Interventional Cardiac Electrophysiology, 2004, 11 : 161 - 166
  • [4] Remote monitoring and follow-up of pacemakers and implantable cardioverter defibrillators
    Burri, Haran
    Senouf, David
    EUROPACE, 2009, 11 (06): : 701 - 709
  • [5] Remote monitoring of subcutaneous implantable cardioverter defibrillators
    Paolo De Filippo
    Mario Luzi
    Antonio D’Onofrio
    Maria Grazia Bongiorni
    Massimo Giammaria
    Giovanni Bisignani
    Endrj Menardi
    Paola Ferrari
    Valter Bianchi
    Stefano Viani
    Cristina Leidi
    Mariolina Lovecchio
    Sergio Valsecchi
    Alessandro Capucci
    Journal of Interventional Cardiac Electrophysiology, 2018, 53 : 373 - 381
  • [6] Remote interrogation and monitoring of implantable cardioverter defibrillators
    Joseph, GK
    Wilkoff, BL
    Dresing, T
    Burkhardt, J
    Khaykin, Y
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2004, 11 (02) : 161 - 166
  • [7] Remote monitoring of implantable cardioverter defibrillators: A prospective analysis
    Schoenfeld, MH
    Compton, SJ
    Mead, RH
    Weiss, DN
    Sherfesee, L
    Englund, J
    Mongeon, LR
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (06): : 757 - 763
  • [8] Assessment of a remote monitoring system for implantable cardioverter defibrillators
    Masella, Cristina
    Zanaboni, Paolo
    Di Stasi, Francesca
    Gilardi, Serena
    Ponzi, Patrizia
    Valsecchi, Sergio
    JOURNAL OF TELEMEDICINE AND TELECARE, 2008, 14 (06) : 290 - 294
  • [9] Initial experience in the remote monitoring of implantable cardioverter defibrillators
    Affolter, J. T.
    Redfem, C.
    Patel, J. C.
    Lewis, A.
    Broadhurst, P. A.
    SCOTTISH MEDICAL JOURNAL, 2008, 53 (02) : 57 - 57
  • [10] Remote monitoring of implantable cardioverter defibrillators: Patient experiences and preferences for follow-up
    Timmermans, Ivy
    Meine, Mathias
    Szendey, Istvan
    Aring, Johannes
    Romero Roldan, Javier
    van Erven, Lieselotte
    Kahlert, Philipp
    Zitron, Edgar
    Mabo, Philippe
    Denollet, Johan
    Versteeg, Henneke
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2019, 42 (02): : 120 - 129