Quantification of oxysterols in human plasma and red blood cells by liquid chromatography high-resolution tandem mass spectrometry

被引:49
|
作者
Pataj, Zoltan [1 ]
Liebisch, Gerhard [1 ]
Schmitz, Gerd [1 ]
Matysik, Silke [1 ]
机构
[1] Univ Hosp Regensburg, Inst Clin Chem & Lab Med, Franz Josef Str Allee 11, D-93053 Regensburg, Germany
关键词
HR-MS (high-resolution mass spectrometry); Orbitrap; Oxysterols; Human plasma; Red blood cells; Niemann-Pick type C; HPLC-ESI-MS/MS; CHOLESTEROL PRECURSORS; STEROL; 27-HYDROXYLASE; OXIDATION-PRODUCTS; BIOLOGICAL SAMPLES; PLANT STEROLS; SERUM SAMPLES; C DISEASE; BIOSYNTHESIS; VALIDATION;
D O I
10.1016/j.chroma.2015.11.015
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Oxysterols are important intermediates in numerous metabolic and catabolic pathways and their biological significance is also proven. The present paper describes a reliable and short liquid chromatography-high-resolution mass spectrometry method (LC-MS/HR-MS) for the quantification of 8 different oxysterols (24(S)-hydroxycholesterol, 25-hydroxycholesterol, 27-hydroxycholesterol, 4 beta-hydroxycholesterol, 7 alpha-hydroxycholesterol, 7 beta-hydroxycholesterol, 7-ketocholesterol and cholestan-3 beta,5 alpha,6 beta-triol) in human plasma and red blood cells. Oxysterols were extracted with iso-octane after saponification of esterified sterols. Due to the poor ionization efficiency of the target compounds in electrospray ionization (ESI) derivatization of the molecules has been performed with N,N-dimethylglycine (DMG). Within less than 8 min we were able to achieve baseline separation of the isobaric 24(S)-hydroxycholesterol, 25-hydroxycholesterol, 27-hydroxycholesterol, 4 beta-hydroxycholesterol, 7 alpha-hydroxycholesterol and 7 beta-hydroxycholesterol. Moreover, high mass resolution was advantageously applied to resolve quasi-isobaric interferences. The method was validated based on the recommendations of US Food and Drug Administration and the European Medicines Agency guidelines. Oxysterol concentrations were determined in human plasma and red blood cells from healthy volunteers. Furthermore, the applicability for clinical use has been proven by the analysis of oxysterols as biomarkers in Niemann-Pick type C or cerebrotendinous xanthomatosis patients. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:82 / 88
页数:7
相关论文
共 50 条
  • [41] Optimization of a method for the determination of a mustard gas biomarker in human blood plasma by liquid chromatography–high-resolution mass spectrometry
    A. V. Braun
    I. V. Rybal’chenko
    M. A. Ponsov
    Ya. V. Stavitskaya
    L. A. Tikhomirov
    A. P. Grechukhin
    Journal of Analytical Chemistry, 2017, 72 : 303 - 308
  • [42] Free oxysterols and bile acids including conjugates - Simultaneous quantification in human plasma and cerebrospinal fluid by liquid chromatography-tandem mass spectrometry
    Reinicke, Madlen
    Schroeter, Jenny
    Mueller-Klieser, Daniel
    Helmschrodt, Christin
    Ceglarek, Uta
    ANALYTICA CHIMICA ACTA, 2018, 1037 : 245 - 255
  • [43] Quantification of voriconazole in plasma by liquid chromatography-tandem mass spectrometry
    Vogeser, M
    Schiel, X
    Spöhrer, U
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2005, 43 (07) : 730 - 734
  • [44] Quantification of folate in whole blood by liquid chromatography tandem mass spectrometry
    Huang, Yuehua
    Lu, Zhiyong
    Whitehead, A. Steven
    Blair, Ian
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2007, 234
  • [45] Structural elucidation of metolachlor photoproducts by liquid chromatography/high-resolution tandem mass spectrometry
    Nicol, Edith
    Genty, Christophe
    Bouchonnet, Stephane
    Bourcier, Sophie
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2015, 29 (23) : 2279 - 2286
  • [46] In vitro metabolism of sunscreen compounds by liquid chromatography/high-resolution tandem mass spectrometry
    Guesmi, Amal
    Ohlund, Leanne
    Sleno, Lekha
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2020, 34 (08)
  • [47] In vitro metabolism of triclosan studied by liquid chromatography–high-resolution tandem mass spectrometry
    Amal Guesmi
    Lekha Sleno
    Analytical and Bioanalytical Chemistry, 2020, 412 : 335 - 342
  • [48] Quantitative and confirmative performance of liquid chromatography coupled to high-resolution mass spectrometry compared to tandem mass spectrometry
    Kaufmann, Anton
    Butcher, Patrick
    Maden, Kathryn
    Walker, Stephan
    Widmer, Miryam
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (07) : 979 - 992
  • [49] Quantification of folate in whole blood by liquid chromatography tandem mass spectrometry
    Huang, Yuehua
    Lu, Zhiyong
    Whitehead, A. Steven
    Blair, Ian
    CHEMICAL RESEARCH IN TOXICOLOGY, 2007, 20 (12) : 2010 - 2010
  • [50] An ultra high performance liquid chromatography-tandem mass spectrometry method for the quantification of linagliptin in human plasma
    Nannapaneni, Nagaraj Kumar
    Jalalpure, Sunil S.
    Muppavarapu, Rajendraprasad
    Sirigiri, Sunil Kumar
    RSC ADVANCES, 2016, 6 (71): : 66756 - 66766