Quantification of oxysterols in human plasma and red blood cells by liquid chromatography high-resolution tandem mass spectrometry

被引:49
|
作者
Pataj, Zoltan [1 ]
Liebisch, Gerhard [1 ]
Schmitz, Gerd [1 ]
Matysik, Silke [1 ]
机构
[1] Univ Hosp Regensburg, Inst Clin Chem & Lab Med, Franz Josef Str Allee 11, D-93053 Regensburg, Germany
关键词
HR-MS (high-resolution mass spectrometry); Orbitrap; Oxysterols; Human plasma; Red blood cells; Niemann-Pick type C; HPLC-ESI-MS/MS; CHOLESTEROL PRECURSORS; STEROL; 27-HYDROXYLASE; OXIDATION-PRODUCTS; BIOLOGICAL SAMPLES; PLANT STEROLS; SERUM SAMPLES; C DISEASE; BIOSYNTHESIS; VALIDATION;
D O I
10.1016/j.chroma.2015.11.015
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Oxysterols are important intermediates in numerous metabolic and catabolic pathways and their biological significance is also proven. The present paper describes a reliable and short liquid chromatography-high-resolution mass spectrometry method (LC-MS/HR-MS) for the quantification of 8 different oxysterols (24(S)-hydroxycholesterol, 25-hydroxycholesterol, 27-hydroxycholesterol, 4 beta-hydroxycholesterol, 7 alpha-hydroxycholesterol, 7 beta-hydroxycholesterol, 7-ketocholesterol and cholestan-3 beta,5 alpha,6 beta-triol) in human plasma and red blood cells. Oxysterols were extracted with iso-octane after saponification of esterified sterols. Due to the poor ionization efficiency of the target compounds in electrospray ionization (ESI) derivatization of the molecules has been performed with N,N-dimethylglycine (DMG). Within less than 8 min we were able to achieve baseline separation of the isobaric 24(S)-hydroxycholesterol, 25-hydroxycholesterol, 27-hydroxycholesterol, 4 beta-hydroxycholesterol, 7 alpha-hydroxycholesterol and 7 beta-hydroxycholesterol. Moreover, high mass resolution was advantageously applied to resolve quasi-isobaric interferences. The method was validated based on the recommendations of US Food and Drug Administration and the European Medicines Agency guidelines. Oxysterol concentrations were determined in human plasma and red blood cells from healthy volunteers. Furthermore, the applicability for clinical use has been proven by the analysis of oxysterols as biomarkers in Niemann-Pick type C or cerebrotendinous xanthomatosis patients. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:82 / 88
页数:7
相关论文
共 50 条
  • [21] Sensitive quantification of rifaximin in human plasma by liquid chromatography-tandem mass spectrometry
    Zhang, Xianhua
    Duan, Jingli
    Li, Ke
    Zhou, Liya
    Zhai, Suodi
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 850 (1-2): : 348 - 355
  • [22] Quantification of artemisinin in human plasma using liquid chromatography coupled to tandem mass spectrometry
    Lindegardh, N.
    Tarning, J.
    Toi, P. V.
    Hien, T. T.
    Farrar, J.
    Singhasivanon, P.
    White, N. J.
    Ashton, M.
    Day, N. P. J.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 49 (03) : 768 - 773
  • [23] Quantification of Clenbuterol in Human Plasma and Urine by Liquid Chromatography-Tandem Mass Spectrometry
    M. Thevis
    T. Schebalkin
    A. Thomas
    W. Schänzer
    Chromatographia, 2005, 62 : 435 - 439
  • [24] Quantification of docetaxel and its metabolites in human plasma by liquid chromatography/tandem mass spectrometry
    Hendrikx, J. J. M. A.
    Dubbelman, A. C.
    Rosing, H.
    Schinkel, A. H.
    Schellens, J. H. M.
    Beijnen, J. H.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (17) : 1925 - 1934
  • [25] Simultaneous quantification of amiloride and hydrochlorothiazide in human plasma by liquid chromatography–tandem mass spectrometry
    Jaivik V.Shah
    Priyanka A.Shah
    Mallika Sanyal
    Pranav S.Shrivastav
    Journal of Pharmaceutical Analysis, 2017, 7 (05) : 288 - 296
  • [26] Lisinopril quantification in human plasma by liquid chromatography-electrospray tandem mass spectrometry
    Padua, AAF
    Barrientos-Astigarraga, RE
    Rezende, VM
    Mendes, GD
    De Nucci, G
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 809 (02): : 211 - 216
  • [27] Quantification of acarbose in human plasma by liquid chromatography-electrospray tandem mass spectrometry
    Raut, BB
    Kolte, BL
    Deo, AA
    Bagool, MA
    Shinde, DB
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2004, 27 (11) : 1759 - 1768
  • [28] Erratum to: Quantification of micafungin in human plasma by liquid chromatography-tandem mass spectrometry
    Giuliana Cangemi
    Sebastiano Barco
    Roberto Bandettini
    Elio Castagnola
    Analytical and Bioanalytical Chemistry, 2014, 406 : 3249 - 3249
  • [29] Development of a liquid chromatography/tandem mass spectrometry assay for the quantification of rabeprazole in human plasma
    Huang, JC
    Xu, Y
    Gao, S
    Rui, L
    Guo, QX
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (16) : 2321 - 2324
  • [30] Quantification of polar drugs in human plasma with liquid chromatography-tandem mass spectrometry
    Deng, Pan
    Chen, Xiaoyan
    Zhong, Dafang
    BIOANALYSIS, 2009, 1 (01) : 187 - 203