The Henday Radisson Dorsey 500kV DC transmission line spacer damper rehabilitation project

被引:0
|
作者
Smith, GW
Mailey, S
机构
关键词
aeolian vibration; helicopters; HVDC transmission lines; measurement; quality control; spacer dampers; vibration control;
D O I
10.1109/TDCLLM.2003.1196470
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Manitoba Hydro (ME) was experiencing spacer damper failures on two +/- 500kV DC transmission lines and elected to refurbish all existing dampers and install additional dampers. The work was completed in a variable climate, over terrain that included over 400 kilometres (248 miles) of swamp and woodland accessible only by air and while lines remained energized to meet system requirements. The project included respacing dampers to improve damping capabilities, completing additional line maintenance, and the development of a mathematical model to check the veracity of damper placement records.
引用
收藏
页码:67 / 73
页数:7
相关论文
共 50 条
  • [31] Investigation on Natural Contamination Deposition of Insulators on ±500kV DC Transmission Lines in Different Environments
    Liu, Qin
    2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 347 - 349
  • [32] Design and Testing of 500kV Double Circuit Monopoles for the Heartland Transmission Project in Edmonton, Alberta
    Kumar, Kishor
    Dwyer, Jason
    ELECTRICAL TRANSMISSION AND SUBSTATION STRUCTURES 2015: TECHNICAL CHALLENGES AND INNOVATIVE SOLUTIONS IN GRID MODERNIZATION, 2015, : 337 - 350
  • [33] Engineering analysis of electrical effects for the COTP 500kV transmission line and EBMUD aqueduct corridor
    Lewis, OC
    Bell, GK
    Ma, JX
    1996 IEEE TRANSMISSION AND DISTRIBUTION CONFERENCE PROCEEDINGS, 1996, : 499 - 507
  • [34] Shielding Failure Risk Assessment for 500kV Typical Transmission Line in Anhui Power Grid
    Zhao, Chun
    Zhen, Shiling
    Xie, Yaoheng
    Gu, Shanqiang
    Ding, Li
    POWER AND ENERGY ENGINEERING CONFERENCE 2010, 2010, : 725 - +
  • [35] The Simulation Analysis and Research of the Electromagnetic Influence of the 500kV AC Transmission Line On the Seismic Station
    Zhao, Jingyuan
    Liu, Mengxuan
    Xu, Hui
    Ren, Boqiang
    2018 2ND IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2018,
  • [36] Research and Design on Walking Device for 500kV Transmission Line 4-bundle Conductors
    Yu, Xiangyong
    Liu, Zhilin
    2016 2ND INTERNATIONAL CONFERENCE ON MECHANICAL, ELECTRONIC AND INFORMATION TECHNOLOGY ENGINEERING (ICMITE 2016), 2016, : 232 - 235
  • [37] 500kV Transmission Line Lightning Transformation Evaluation Based on Improved Analytic Hierarchy Process
    Duan, R. C.
    Wang, F. H.
    Liu, Y. D.
    Huang, R. H.
    2014 IEEE PES T&D CONFERENCE AND EXPOSITION, 2014,
  • [38] Evaluation of Auto-reclose Performance of 500kV Transmission Line with Shunt Reactor in Indonesia
    Kusuma, Aristo Adi
    Pramana, Putu Agus Aditya
    Munir, Buyung Sofiarto
    Tambunan, Handrea Bernando
    PROCEEDINGS OF 2018 THE 10TH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY AND ELECTRICAL ENGINEERING (ICITEE), 2018, : 320 - 324
  • [39] Live Working on Electrode line of ±800kV DC Transmission Project
    Tang Pan
    Fang Yuqun
    Liu Kai
    Liu Ting
    2017 1ST INTERNATIONAL CONFERENCE ON ELECTRICAL MATERIALS AND POWER EQUIPMENT (ICEMPE), 2017, : 691 - 694
  • [40] Development and Application of ±500 kV DC Transmission Line Arrester in China Power Grid
    Gu, Shanqiang
    Wan, Shuai
    Wang, Jian
    Chen, Jiahong
    Li, Tao
    IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (01) : 209 - 217