Comparative Dose of Contrast-Enhanced Spectral Mammography (CESM), Digital Mammography, and Digital Breast Tomosynthesis

被引:42
|
作者
Phillips, Jordana [1 ,2 ]
Mihai, Georgeta [1 ,2 ]
Hassonjee, Sarah Esaa [1 ,2 ]
Raj, Sean D. [1 ,2 ]
Palmer, Matthew R. [1 ,2 ]
Brook, Alexander [1 ,2 ]
Zhang, Da [1 ,2 ]
机构
[1] Harvard Med Sch, Dept Radiol, 330 Brookline Ave,4th Fl, Boston, MA 02215 USA
[2] Beth Israel Deaconess Med Ctr, 330 Brookline Ave,4th Fl, Boston, MA 02215 USA
关键词
contrast-enhanced digital mammography; contrast-enhanced mammography; contrast-enhanced spectral mammography; radiation dose; DOSIMETRY PROTOCOLS; RADIATION-EXPOSURE; PERFORMANCE; MRI; UK;
D O I
10.2214/AJR.17.19036
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study is to provide a more accurate estimation of the radiation dose of contrast-enhanced spectral mammography (CESM) relative to that of 2D digital mammography and tomosynthesis using phantom and patient data and an accepted dosimetry protocol that eliminates vendor-specific average glandular dose (AGD) estimates while including breast density. MATERIALS AND METHODS. Patient and phantom AGD estimation was performed using two vendors (system 1 and system 2) in five imaging modes, including 2D, 3D, and CESM imaging. Patient AGD was retrospectively estimated from 45 patients who underwent mammography with all imaging modes during 2012-2016. Patient and phantom AGD were estimated using accepted European and International Atomic Energy Agency protocols for dosimetry and were compared across imaging modes using a paired t test with Bonferroni correction. RESULTS. Phantom data showed that the imaging modes with the lowest to highest AGDs were system 1 2D, followed by system 2 2D and system 2 3D, which had comparable values (p = 0.6), followed by system 1 CESM, and then by system 2 2D plus 3D. One hundred eighty views in 45 patients showed that the system 1 CESM AGD was 1.8 times greater than the system 1 21) AU) (p < 0.001), 1.2 times greater than the system 2 21) AO) (p < 0.001), 1.2 times greater than the system 2 3D AGD (p < 0.001), and 0.6 times less than the system 2 2D plus 3D AGD (p < 0.001). CONCLUSION. The CESM dose for system 1 is within an acceptable range as compared with other commonly performed mammographic examinations and should not preclude its use as a diagnostic breast imaging tool.
引用
收藏
页码:839 / 846
页数:8
相关论文
共 50 条
  • [41] Contrast-Enhanced Spectral Mammography in Breast Imaging
    Lancaster, Rachael B.
    Gulla, Shannon
    De Los Santos, Jennifer
    Umphrey, Heidi R.
    SEMINARS IN ROENTGENOLOGY, 2018, 53 (04) : 294 - 300
  • [42] Comparative study between contrast-enhanced mammography, tomosynthesis, and breast ultrasound as complementary techniques to mammography in dense breast parenchyma
    Azzam, Heba
    Kamal, Rasha Mohamed
    Hanafy, Mennatallah Mohamed
    Youssef, Ayda
    Hashem, Lamia Mohamed Bassam
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2020, 51 (01):
  • [43] Comparative study between contrast-enhanced mammography, tomosynthesis, and breast ultrasound as complementary techniques to mammography in dense breast parenchyma
    Heba Azzam
    Rasha Mohamed Kamal
    Mennatallah Mohamed Hanafy
    Ayda Youssef
    Lamia Mohamed Bassam Hashem
    Egyptian Journal of Radiology and Nuclear Medicine, 51
  • [44] Retrospective Comparison of Contrast-Enhanced Spectral Mammography with Digital Mammography in Assessing Tumor Size in 668 Cases of Breast Cancer
    Lorek, Andrzej
    Steinhof-Radwanska, Katarzyna
    Barczyk-Gutkowska, Anna
    Zarebski, Wojciech
    Boratyn-Nowicka, Agnieszka
    Bobola, Agnieszka
    Lorek, Joanna
    Stojcev, Zoran
    Gisterek, Iwona
    MEDICAL SCIENCE MONITOR, 2020, 26
  • [45] Comparison of Contrast-Enhanced Mammography With Conventional Digital Mammography in Breast Cancer Screening: A Pilot Study
    Kim, Geunwon
    Phillips, Jordana
    Cole, Elodia
    Brook, Alexander
    Mehta, Tejas
    Slanetz, Priscilla
    Fishman, Michael D. C.
    Karimova, Evguenia
    Mehta, Rashmi
    Loo, Parisa
    Resteghini, Nancy
    Raj, Sean
    Dialani, Vandana
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2019, 16 (10) : 1456 - 1463
  • [46] Breast Adenomyoepithelioma Ultrasonography, Elastography, Digital Mammography, Contrast-Enhanced Digital Mammography, and Pathology Findings of This Rare Type of Breast Tumor
    Gkali, Christina An
    Chalazonitis, Athanasios N.
    Feida, Eleni
    Dimitrakakis, Constantine
    Sotiropoulou, Maria
    ULTRASOUND QUARTERLY, 2015, 31 (03) : 185 - 188
  • [47] Role of contrast enhanced spectral mammography (CESM) in the evaluation of breast lesions
    Chen, R.
    Chong, B. K.
    Chotai, N.
    Tan, E. Y.
    EUROPEAN JOURNAL OF CANCER, 2024, 200 : 21 - 21
  • [48] Background Parenchymal Enhancement at Contrast-Enhanced Spectral Mammography (CESM) as a Breast Cancer Risk Factor
    Sorin, Vera
    Yagil, Yael
    Shalmon, Anat
    Gotlieb, Michael
    Faermann, Renata
    Halshtok-Neiman, Osnat
    Sklair-Levy, Miri
    ACADEMIC RADIOLOGY, 2020, 27 (09) : 1234 - 1240
  • [49] Pretreatment staging of breast cancer: Is contrast-enhanced digital mammography the solution?
    Doutriaux-Dumoulin, Isabelle
    IMAGERIE DE LA FEMME, 2024, 34 (02)
  • [50] Primary breast edema on contrast-enhanced digital mammography: a preliminary experience
    Marwa A. Haggag
    Soha T. Hamed
    Aya Sedky Abd El Latif Mawas
    Egyptian Journal of Radiology and Nuclear Medicine, 52