Track replica method applied to CR-39

被引:3
|
作者
Borgonovo, L [1 ]
Saint-Martin, G [1 ]
Bernaola, OA [1 ]
Nemirovsky, I [1 ]
Kirschbaum, W [1 ]
机构
[1] Comis Nacl Energia Atom, RA-1429 Buenos Aires, DF, Argentina
关键词
nuclear tracks; CR-39; replicas;
D O I
10.1016/S1350-4487(97)00190-X
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The replica method has been applied before to detector materials which can be easily removed from the replica by specific solvents. Taking into account that CR-39, one of the most sensitive ion track detectors, can not be removed by any solvent without altering the replica materials, the technique had to be adapted for using with this material. Replicas for normal and grazing angle ion incidence on CR-39 were obtained and observed with a transmission electron microscope.
引用
收藏
页码:821 / 822
页数:2
相关论文
共 50 条
  • [41] Calibration study on the triton response of CR-39 track detector
    Yamauchi, T
    Oda, K
    Tanabe, S
    Matsumoto, H
    Miyake, H
    RADIATION MEASUREMENTS, 1997, 28 (1-6) : 191 - 196
  • [42] XE-136 AND AU-197 ION TRACK REGISTRATION RESPONSE IN CR-39 AND CR-39 (DOP) DETECTORS
    KUMAR, A
    PRASAD, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1994, 93 (03): : 277 - 281
  • [43] A new model to account for track overlap in CR-39 data
    Zylstra, A. B.
    Frenje, J. A.
    Seguin, F. H.
    Johnson, M. Gatu
    Casey, D. T.
    Rosenberg, M. J.
    Waugh, C.
    Sinenian, N.
    Manuel, M. J. -E.
    Li, C. K.
    Petrasso, R. D.
    Kim, Y.
    Herrmann, H. W.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 681 : 84 - 90
  • [44] α-Spectroscopy on CR-39 track detectors for the dosimetry of radon daughters
    Mozzo, P.
    Trotti, F.
    Temporin, A.
    Lanciai, M.
    Predicatori, F.
    Righetti, F.
    Tacconi, A.
    Environment International, 1997, 22 (SUPPL. 1):
  • [45] MEASUREMENTS OF RADON IN DWELLINGS WITH CR-39 TRACK DETECTORS.
    Majborn, B.
    Nuclear tracks, 1985, 12 (1-6): : 763 - 766
  • [46] TRACK-SIZE DISTRIBUTION OF ELECTROCHEMICALLY ETCHED CR-39
    AZIMIGARAKANI, D
    BOSCHUNG, M
    WERNLI, C
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1991, 19 (1-4): : 443 - 444
  • [47] A CR-39 TRACK DOSIMETER FOR ROUTINE INDIVIDUAL NEUTRON MONITORING
    LUSZIKBHADRA, M
    ALBERTS, WG
    DERRICO, F
    DIETZ, E
    GULDBAKKE, S
    MATZKE, M
    RADIATION PROTECTION DOSIMETRY, 1994, 55 (04) : 285 - 293
  • [48] Neutron spectrometry using CR-39 track etch detectors
    Phillips, Gary W.
    Spann, Jerrette E.
    Bogard, James S.
    VoDinh, Tuan
    Emfietzoglou, Dimitris
    Devine, Robert T.
    Moscovitch, Marko
    RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) : 457 - 460
  • [49] Particularization of alpha contamination using CR-39 track detectors
    M. F. Zaki
    Y. H. El-Shaer
    Pramana, 2007, 69 : 567 - 574
  • [50] STUDIES ON NITROGEN MAPPING BY VARIOUS CR-39 TRACK DETECTORS
    SOMOGYI, G
    VARGA, Z
    HUNYADI, I
    FREYER, K
    TREUTLER, HC
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 949 - 952