Improved Controller Design of Grid Friendly™ Appliances for Primary Frequency Response

被引:0
|
作者
Lian, Jianming [1 ]
Sun, Yannan [1 ]
Marinovici, Laurentiu D. [1 ]
Kalsi, Karanjit [1 ]
机构
[1] Pacific NW Natl Lab, 902 Battelle Blvd, Richland, WA 99352 USA
关键词
Grid Friendly (TM) Appliance; autonomous load control; frequency response; curtailing frequency threshold;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The Grid Friendly (TM) Appliance (GFA) controller, developed at Pacific Northwest National Laboratory, was originally designed to autonomously switch off appliances by detecting under-frequency events. In this paper, the feasibility of using the GFA controller to provide primary frequency response is investigated. In particular, the impacts of an important design parameter, i.e., curtailing frequency threshold, on the primary frequency response are carefully analyzed for different situations. In the normal situation, the current method of selecting curtailing frequency thresholds for GFAs is found to be insufficient to guarantee the desired performance especially when the frequency deviation is shallow. In the extreme situations, the power reduction of online GFAs could be so excessive that it can even impact the system frequency negatively. As the first step towards the efforts to make GFAs suitable for providing primary frequency response, the existing controller design is improved by modifying the strategy of selecting curtailing frequency thresholds to ensure the effectiveness of GFAs in the normal situation.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Sliding Mode Fixed Frequency Current Controller Design for Grid-Connected NPC Inverter
    Sebaaly, Fadia
    Vahedi, Hani
    Kanaan, Hadi Y.
    Moubayed, Nazih
    Al-Haddad, Kamal
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2016, 4 (04) : 1397 - 1405
  • [42] Sizing of an Energy Storage System for Grid Inertial Response and Primary Frequency Reserve
    Knap, Vaclav
    Chaudhary, Sanjay K.
    Stroe, Daniel-Ioan
    Swierczynski, Maciej
    Craciun, Bogdan-Ionut
    Teodorescu, Remus
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2016, 31 (05) : 3447 - 3456
  • [43] A Detection Method for Response Time of Overall Primary Frequency Regulation of Power Grid
    Wang, Bo
    Liu, Dong
    Shan, Xin
    Su, Dawei
    Zhang, Qibing
    2017 IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2017, : 871 - 876
  • [44] Design and Implementation of an Improved Controller for Parallel-Connected 400 Hz Frequency Converters
    Tamyurek, B.
    Birdane, E.
    Ceyhan, A.
    2010 TWENTY-FIFTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2010, : 1197 - 1203
  • [45] An Improved Frequency-domain Method for the Fractional Order PIADP Controller Optimal Design
    Zheng, Weijia
    Luo, Ying
    Chen, Yangquan
    Pi, Youguo
    Yu, Wei
    IFAC PAPERSONLINE, 2018, 51 (04): : 681 - 686
  • [46] Multiconverter controller design for an infrared heater grid
    Adonis, M.
    Kahn, M. T. E.
    2009 AFRICON, VOLS 1 AND 2, 2009, : 589 - 594
  • [47] The Design and Simulation of Wind Turbine Grid Controller
    Ping Li
    Zhang Kai-feng
    Xiong Yong-liang
    MECHANICAL AND AEROSPACE ENGINEERING, PTS 1-7, 2012, 110-116 : 2481 - +
  • [48] Multivariable low order structured-controller design by frequency response approximation
    Trierweiler, JO
    Müller, R
    Engell, S
    BRAZILIAN JOURNAL OF CHEMICAL ENGINEERING, 2000, 17 (4-7) : 793 - 807
  • [49] Multivariable Controller Design Achieving Diagonal Dominance Using Frequency Response Data
    Shinoda, Shogo
    Yubai, Kazuhiro
    Yashiro, Daisuke
    Hirai, Junji
    ELECTRONICS AND COMMUNICATIONS IN JAPAN, 2017, 100 (10) : 12 - 23
  • [50] Direct Frequency Response Function Based, Uncertainty Accomodating Optimal Controller Design
    Holze, Matthew
    Lacy, Seth
    Babuska, Vit
    Bernstein, Dennis
    2009 AMERICAN CONTROL CONFERENCE, VOLS 1-9, 2009, : 1046 - 1051