MediSPECT: Single photon emission computed tomography system for small field of view small animal imaging based on a CdTe hybrid pixel detector

被引:22
|
作者
Accorsi, R.
Autiero, M.
Celentano, L.
Chmeissani, M.
Cozzolino, R.
Curion, A. S.
Frallicciardi, P.
Laccetti, P.
Lanza, R. C.
Lauria, A.
Maiorino, M.
Marotta, M.
Mettivier, G.
Montesi, M. C.
Riccio, P.
Roberti, G.
Russo, P.
机构
[1] Univ Naples Federico II, Dipartimento Sci Fis, I-80126 Naples, Italy
[2] Univ Naples Federico II, Dipartimento Sci Biomorfol & Funz, I-80126 Naples, Italy
[3] Childrens Hosp Philadelphia, Dept Radiol, Philadelphia, PA 19104 USA
[4] IFAE, Barcelona, Spain
[5] Ist Nazl Fis Nucl, Sez Napoli, I-80125 Naples, Italy
[6] Univ Naples Federico II, Dipartimento Biol Strutturale & Funz, I-80126 Naples, Italy
[7] MIT, Dept Nucl Engn, Cambridge, MA 02139 USA
[8] Univ Naples Federico II, Dipartimento Med Clin & Sperimentale, I-80126 Naples, Italy
[9] Univ Naples Federico II, Dipartimento Biol & Patol Cellulare & Mol, I-80126 Naples, Italy
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2007年 / 571卷 / 1-2期
关键词
SPECT; small animal imaging; Medipix2; CdTe;
D O I
10.1016/j.nima.2006.10.025
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe MediSPECT, a new scanner developed at University and INFN Napoli, for SPECT studies on small animals with a small field of view (FOV) and high spatial resolution. The CdTe pixel detector (a 256 x 256 matrix of 55 pm square pixels) operating in single photon counting for detection of gamma-rays with low and medium energy (e.g. I-121. 27-35 keV, Tc-99m, 140 keV), is bump bonded to the Medipix2 readout chip. The FOV of the MediSPECT scanner with a coded aperture mask collimator ranges from 6.3 mm (system spatial resolution 110 mu m at 27-35 keV) to 24.3 mm. With a 0.30 mm pinhole the FOV ranges from 2.4 to 29mm (where the system spatial resolution is 1.0 mm at 27-35 keV and 2.0 mm at 140keV). MediSPECT will be used for in vivo imaging of small organs or tissue structures in mouse, e.g., brain, thyroid, heart or tumor. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:44 / 47
页数:4
相关论文
共 50 条
  • [41] Relative Merits of Single-Photon Emission Computed Tomography and PET Perfusion Imaging: A Cardiologist's View
    Abdulbaki, Abdulrahman
    Modi, Kalgi
    Takalkar, Amol M.
    PET CLINICS, 2011, 6 (04) : 431 - +
  • [42] A Spartan3E-based low-cost system for gamma-ray detection in small single photon emission computed tomography or positron emission tomography systems
    Fysikopoulos, E.
    Georgiou, M.
    Efthimiou, N.
    David, S.
    Loudos, G.
    Matsopoulos, G.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (11)
  • [43] Evaluation of Cadmium-Zinc-Telluride Detector-based Single-Photon Emission Computed Tomography for Nuclear Cardiology: a Comparison with Conventional Anger Single-Photon Emission Computed Tomography
    Niimi T.
    Nanasato M.
    Sugimoto M.
    Maeda H.
    Nuclear Medicine and Molecular Imaging, 2017, 51 (4) : 331 - 337
  • [44] SemiSPECT: A small-animal imaging system based on eight CdZnTe pixel detectors
    Peterson, TE
    Kim, H
    Crawford, NJ
    Gershman, BM
    Hunter, WCJ
    Barber, HB
    Furenlid, LR
    Wilson, DW
    Woolfenden, JM
    Barrett, HH
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1844 - 1847
  • [45] Simultaneous Dual-Contrast Imaging of Small Bowel With Iodine and Bismuth Using Photon-Counting-Detector Computed Tomography A Feasibility Animal Study
    Ren, Liqiang
    Rajendran, Kishore
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Yu, Lifeng
    INVESTIGATIVE RADIOLOGY, 2020, 55 (10) : 688 - 694
  • [46] A compact frequency-domain photon migration system for integration into commercial hybrid small animal imaging scanners for fluorescence tomography
    Darne, Chinmay D.
    Lu, Yujie
    Tan, I-Chih
    Zhu, Banghe
    Rasmussen, John C.
    Smith, Anne M.
    Yan, Shikui
    Sevick-Muraca, Eva M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (24):
  • [47] Impact of cardiac hybrid single-photon emission computed tomography/computed tomography imaging on choice of treatment strategy in coronary artery disease
    Pazhenkottil, Aju P.
    Nkoulou, Rene N.
    Ghadri, Jelena-Rima
    Herzog, Bernhard A.
    Kueest, Silke M.
    Husmann, Lars
    Wolfrum, Mathias
    Goetti, Robert
    Buechel, Ronny R.
    Gaemperli, Oliver
    Luescher, Thomas F.
    Kaufmann, Philipp A.
    EUROPEAN HEART JOURNAL, 2011, 32 (22) : 2824 - 2829
  • [48] Therapeutic efficacy of coronary artery bypass grafting evaluated by hybrid cardiac single-photon emission computed tomography/computed tomography imaging
    Ishii, Yosuke
    Kumita, Shin-Ichiro
    Nitta, Takashi
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 56 (06) : 1206 - 1206
  • [49] Computed Tomography System Using a New MPGD for Small Animal Imaging with Energy Resolving Capability
    Carramate, L. F. N. D.
    Oliveira, C. A. B.
    Silva, A. L. M.
    Azevedo, C. D. R.
    Correia, P. M. M.
    Da Silva, A. M.
    Veloso, J. F. C. A.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3664 - 3666
  • [50] Hybrid Magnetic Resonance Imaging with Single Photon Emission Computed Tomography/Computed Tomography Bone Scan for Diagnosis Of Avascular Necrosis of Femoral Head
    Ng, Fung Him
    Lai, Terence Kin Bong
    Lam, Sun Yu
    Pan, Nin Yuan
    Luk, Wing Hang
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2021, 11