MediSPECT: Single photon emission computed tomography system for small field of view small animal imaging based on a CdTe hybrid pixel detector

被引:22
|
作者
Accorsi, R.
Autiero, M.
Celentano, L.
Chmeissani, M.
Cozzolino, R.
Curion, A. S.
Frallicciardi, P.
Laccetti, P.
Lanza, R. C.
Lauria, A.
Maiorino, M.
Marotta, M.
Mettivier, G.
Montesi, M. C.
Riccio, P.
Roberti, G.
Russo, P.
机构
[1] Univ Naples Federico II, Dipartimento Sci Fis, I-80126 Naples, Italy
[2] Univ Naples Federico II, Dipartimento Sci Biomorfol & Funz, I-80126 Naples, Italy
[3] Childrens Hosp Philadelphia, Dept Radiol, Philadelphia, PA 19104 USA
[4] IFAE, Barcelona, Spain
[5] Ist Nazl Fis Nucl, Sez Napoli, I-80125 Naples, Italy
[6] Univ Naples Federico II, Dipartimento Biol Strutturale & Funz, I-80126 Naples, Italy
[7] MIT, Dept Nucl Engn, Cambridge, MA 02139 USA
[8] Univ Naples Federico II, Dipartimento Med Clin & Sperimentale, I-80126 Naples, Italy
[9] Univ Naples Federico II, Dipartimento Biol & Patol Cellulare & Mol, I-80126 Naples, Italy
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2007年 / 571卷 / 1-2期
关键词
SPECT; small animal imaging; Medipix2; CdTe;
D O I
10.1016/j.nima.2006.10.025
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe MediSPECT, a new scanner developed at University and INFN Napoli, for SPECT studies on small animals with a small field of view (FOV) and high spatial resolution. The CdTe pixel detector (a 256 x 256 matrix of 55 pm square pixels) operating in single photon counting for detection of gamma-rays with low and medium energy (e.g. I-121. 27-35 keV, Tc-99m, 140 keV), is bump bonded to the Medipix2 readout chip. The FOV of the MediSPECT scanner with a coded aperture mask collimator ranges from 6.3 mm (system spatial resolution 110 mu m at 27-35 keV) to 24.3 mm. With a 0.30 mm pinhole the FOV ranges from 2.4 to 29mm (where the system spatial resolution is 1.0 mm at 27-35 keV and 2.0 mm at 140keV). MediSPECT will be used for in vivo imaging of small organs or tissue structures in mouse, e.g., brain, thyroid, heart or tumor. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:44 / 47
页数:4
相关论文
共 50 条
  • [31] Aortic root abscess: Multimodality imaging with computed tomography and gallium-67 citrate single-photon emission computed tomography/computed tomography hybrid imaging
    McWilliams, Eric T.
    Yavari, Arash
    Raman, Vivek
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2011, 5 (02) : 122 - 124
  • [32] RECENT DEVELOPMENTS IN SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY WITH A SMALL GERMANIUM CAMERA
    ORTENDAHL, DA
    KAUFMAN, L
    ROWAN, W
    HERFKENS, R
    PRICE, D
    JOURNAL OF NUCLEAR MEDICINE, 1980, 21 (06) : P17 - P17
  • [33] Design and feasibility study of a single photon emission microscope system for small animal I-125 imaging
    Meng, LJ
    Clinthorne, NH
    Skinner, S
    Hay, RV
    Gross, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) : 1168 - 1178
  • [34] Small-Animal Imaging Using Clinical Positron Emission Tomography/Computed Tomography and Super-Resolution
    DiFilippo, Frank P.
    Patel, Sagar
    Asosingh, Kewal
    Erzurum, Serpil C.
    MOLECULAR IMAGING, 2012, 11 (03) : 210 - 219
  • [35] SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY WITH INCREASED SAMPLING DENSITY AT CENTRAL REGION OF FIELD-OF-VIEW.
    Nohara, Norimasa
    Murayama, Hideo
    Tanaka, Eiichi
    IEEE Transactions on Nuclear Science, 1986, NS-34 (01) : 359 - 363
  • [36] Hybrid cardiac single photon emission computed tomography/computed tomography imaging with myocardial perfusion single photon emission computed tomography and multidetector computed tomography coronary angiography for the assessment of unstable angina pectoris after coronary artery bypass grafting
    Ghersin, Eduard
    Keidar, Zohar
    Rispler, Shmuel
    Litmanovich, Diana
    Bar-Shalom, Rachel
    Roguin, Ariel
    Soil, Adrian
    Israel, Ora
    Engel, Ahuva
    CIRCULATION, 2006, 114 (06) : E237 - E239
  • [37] High-resolution 125I small animal imaging with a coded aperture and a hybrid pixel detector
    Accorsi, Roberto
    Celentano, Luigi
    Laccetti, Paolo
    Lanza, Richard C.
    Marotta, Marcello
    Mettivier, Giovanni
    Montesi, Maria Cristina
    Roberti, Giuseppe
    Russo, Paolo
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (01) : 481 - 490
  • [38] Imaging of Activated Macrophages in Experimental Osteoarthritis Using Folate-Targeted Animal Single-Photon-Emission Computed Tomography/Computed Tomography
    Piscaer, Tom M.
    Mueller, Cristina
    Mindt, Thomas L.
    Lubberts, Erik
    Verhaar, Jan A. N.
    Krenning, Eric P.
    Schibli, Roger
    De Jong, Marjon
    Weinans, Harrie
    ARTHRITIS AND RHEUMATISM, 2011, 63 (07): : 1898 - 1907
  • [39] Positron Emission Tomography Kinetic Modeling Algorithms for Small Animal Dopaminergic System Imaging
    Topping, Geoffrey J.
    Dinelle, Katie
    Kornelsen, Rick
    McCormick, Siobhan
    Holden, James E.
    Sossi, Vesna
    SYNAPSE, 2010, 64 (03) : 200 - 208
  • [40] Pharmacological challenge and synaptic response - assessing dopaminergic function in the rat striatum with small animal single-photon emission computed tomography (SPECT) and positron emission tomography (PET)
    Nikolaus, Susanne
    Larisch, Rolf
    Vosberg, Henning
    Beu, Markus
    Wirrwar, Andreas
    Antke, Christina
    Kley, Konstantin
    Silva, Maria Angelica De Souza
    Huston, Joseph P.
    Mueller, Hans-Wilhelm
    REVIEWS IN THE NEUROSCIENCES, 2011, 22 (06) : 625 - 645