MediSPECT: Single photon emission computed tomography system for small field of view small animal imaging based on a CdTe hybrid pixel detector

被引:22
|
作者
Accorsi, R.
Autiero, M.
Celentano, L.
Chmeissani, M.
Cozzolino, R.
Curion, A. S.
Frallicciardi, P.
Laccetti, P.
Lanza, R. C.
Lauria, A.
Maiorino, M.
Marotta, M.
Mettivier, G.
Montesi, M. C.
Riccio, P.
Roberti, G.
Russo, P.
机构
[1] Univ Naples Federico II, Dipartimento Sci Fis, I-80126 Naples, Italy
[2] Univ Naples Federico II, Dipartimento Sci Biomorfol & Funz, I-80126 Naples, Italy
[3] Childrens Hosp Philadelphia, Dept Radiol, Philadelphia, PA 19104 USA
[4] IFAE, Barcelona, Spain
[5] Ist Nazl Fis Nucl, Sez Napoli, I-80125 Naples, Italy
[6] Univ Naples Federico II, Dipartimento Biol Strutturale & Funz, I-80126 Naples, Italy
[7] MIT, Dept Nucl Engn, Cambridge, MA 02139 USA
[8] Univ Naples Federico II, Dipartimento Med Clin & Sperimentale, I-80126 Naples, Italy
[9] Univ Naples Federico II, Dipartimento Biol & Patol Cellulare & Mol, I-80126 Naples, Italy
关键词
SPECT; small animal imaging; Medipix2; CdTe;
D O I
10.1016/j.nima.2006.10.025
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe MediSPECT, a new scanner developed at University and INFN Napoli, for SPECT studies on small animals with a small field of view (FOV) and high spatial resolution. The CdTe pixel detector (a 256 x 256 matrix of 55 pm square pixels) operating in single photon counting for detection of gamma-rays with low and medium energy (e.g. I-121. 27-35 keV, Tc-99m, 140 keV), is bump bonded to the Medipix2 readout chip. The FOV of the MediSPECT scanner with a coded aperture mask collimator ranges from 6.3 mm (system spatial resolution 110 mu m at 27-35 keV) to 24.3 mm. With a 0.30 mm pinhole the FOV ranges from 2.4 to 29mm (where the system spatial resolution is 1.0 mm at 27-35 keV and 2.0 mm at 140keV). MediSPECT will be used for in vivo imaging of small organs or tissue structures in mouse, e.g., brain, thyroid, heart or tumor. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:44 / 47
页数:4
相关论文
共 50 条
  • [1] SMALL ANIMAL IMAGING WITH PINHOLE SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY
    STRAND, SE
    IVANOVIC, M
    ERLANDSSON, K
    FRANCESCHI, D
    BUTTON, T
    SJOGREN, K
    WEBER, DA
    CANCER, 1994, 73 (03) : 981 - 984
  • [2] Improving the quantitation accuracy in noninvasive small animal single photon emission computed tomography imaging
    Cheng, Dengfeng
    Rusckowski, Mary
    Pretorius, P. Hendrik
    Chen, Ling
    Xiao, Nan
    Liu, Yuxia
    Liu, Guozheng
    Liang, Minmin
    Liu, Xinrong
    Dou, Shuping
    Hnatowich, Donald J.
    NUCLEAR MEDICINE AND BIOLOGY, 2011, 38 (06) : 843 - 848
  • [3] Small animal imaging with high resolution single photon emission tomography
    Acton, PD
    Kung, HF
    NUCLEAR MEDICINE AND BIOLOGY, 2003, 30 (08) : 889 - 895
  • [4] Investigation of Attenuation Correction for Small-Animal Single Photon Emission Computed Tomography
    Lee, Hsin-Hui
    Chen, Jyh-Cheng
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2013, 2013
  • [5] Broadband X-ray Fluorescence Emission Tomography with A Small Pixel CdTe Imaging-Spectrometry Detector
    Li, Mohan
    George, Jon
    Meng, Ling-Jian
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [6] SMALL-ANIMAL MOLECULAR IMAGING WITH PORTABLE DEVICES ON CLINICAL PINHOLE SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHY SYSTEMS
    Hu, Chi-Min
    Lin, Ming-Shien
    Su, Kuan-Hao
    Liu, Ren-Shyan
    Chen, Jyh-Cheng
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2012, 24 (06): : 485 - 493
  • [7] Diagnostic performance of cardiac hybrid imaging of single photon emission computed tomography and coronary computed tomography
    Nishio, M.
    Nemoto, T.
    Asai, M.
    Kashiwase, K.
    Matsuo, K.
    Hirata, A.
    Ueda, Y.
    EUROPEAN HEART JOURNAL, 2012, 33 : 777 - 777
  • [8] SemiSPECT: A small-animal single-photon emission computed tomography (SPECT) imager based on eight cadmium zinc telluride (CZT) detector arrays
    Kim, H
    Furenlid, LR
    Crawford, MJ
    Wilson, DW
    Barber, HB
    Peterson, TE
    Hunter, WCJ
    Liu, ZL
    Woolfenden, JM
    Barrett, HH
    MEDICAL PHYSICS, 2006, 33 (02) : 465 - 474
  • [9] Motion-tracking technique in unrestrained small-animal single-photon emission computed tomography
    Weisenberger, Andrew G.
    Lee, Seungjoon
    Smith, Mark F.
    REVIEWS IN THE NEUROSCIENCES, 2011, 22 (06) : 657 - 663
  • [10] Hybrid Small Animal Imaging System Combining Magnetic Resonance Imaging With Fluorescence Tomography Using Single Photon Avalanche Diode Detectors
    Stuker, Florian
    Baltes, Christof
    Dikaiou, Katerina
    Vats, Divya
    Carrara, Lucio
    Charbon, Edoardo
    Ripoll, Jorge
    Rudin, Markus
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (06) : 1265 - 1273