Trace-level determination of 1,4-dioxane in water by isotopic dilution GC and GC-MS

被引:40
|
作者
Draper, WM [1 ]
Dhoot, JS [1 ]
Remoy, JW [1 ]
Perera, SK [1 ]
机构
[1] Calif Dept Hlth Serv, Sanitat & Radiat Lab Branch, Berkeley, CA 94704 USA
关键词
D O I
10.1039/b002345k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The volatile and polar solvent 1,4-dioxane has recently been reported as a contaminant of ground and surface waters, establishing the need to determine this substance in drinking water. This investigation established that 1,4-dioxane can be determined in water by various techniques including direct aqueous injection (DAI) gas chromatography (GC) and purge and trap GC-mass spectrometry (MS). Purge and trap GC-MS is limited by 1,4-dioxane's poor purge efficiency, resulting in detection limits up to 100 times greater than the efficiently purged volatile organic compounds. To attain the sensitivity required for drinking water monitoring, a method based on continuous liquid-liquid extraction with dichloromethane was developed. Isotope dilution was more accurate and reproducible than quantification with external standards, and the improvement in precision led to a lower method detection limit, 0.2 mu g L-1, using a quadrupole ion trap instrument in the electron ionization mode. Isotope dilution accuracy approached 100% in ppb determinations. Isotopic dilution quantification was also possible using a non-selective GC detector owing to the high efficiency of capillary GC columns that resolve the deuterium-labeled solvent from the natural isotopes.
引用
收藏
页码:1403 / 1408
页数:6
相关论文
共 50 条
  • [41] Determination of chloride in crude oil using isotope dilution GC-MS: A comparative study
    Gajdosechova, Zuzana
    Dutta, Moumita
    Lopez-Linares, Francisco
    Mello, Paola de Azevedo
    Iop, Gabrielle Dineck
    Moraes Flores, Erico Marlon
    Mester, Zoltan
    Pagliano, Enea
    FUEL, 2021, 285
  • [42] Rapid determination of natural and synthetic hormones in biosolids and poultry manure by isotope dilution GC-MS/MS
    Albero, Beatriz
    Sanchez-Brunete, Consuelo
    Miguel, Esther
    Aznar, Ramon
    Tadeo, Jose L.
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (07) : 811 - 819
  • [43] Simple, rapid, and sensitive determination of odorous compounds in water by GC-MS
    Shin, HS
    Ahn, HS
    CHROMATOGRAPHIA, 2004, 59 (1-2) : 107 - 113
  • [44] Determination of Organotin Compounds in Water Soluble Paints and Adhesives by GC-MS
    Kawakami, Tsuyoshi
    Isama, Kazuo
    Nakashima, Harunobu
    Ooshima, Tomoko
    Tsuchiya, Toshie
    Matsuoka, Atsuko
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 2010, 130 (02): : 223 - 235
  • [45] Determination of phthalate acid esters in water and sediment samples by GC-MS
    Shao, Xiao-ling
    Zou, Yan-min
    Wang, Fu-xing
    Zhang, Zhen
    Wang, Song-mei
    Han, Song-lei
    Wang, Sha-sha
    Chen, Yao
    Wu, Xiang-yang
    Chen, Zhong-lin
    PROGRESS IN ENVIRONMENTAL SCIENCE AND ENGINEERING, PTS 1-4, 2013, 610-613 : 157 - +
  • [46] A novel GC-MS method for the determination and quantification of metformin in surface water
    Goedecke, C.
    Fettig, I.
    Piechotta, C.
    Philipp, R.
    Geissen, S. U.
    ANALYTICAL METHODS, 2017, 9 (10) : 1580 - 1584
  • [47] A SDME/GC-MS methodology for determination of organophosphate and pyrethroid pesticides in water
    Pinheiro, Anselmo de Souza
    da Rocha, Gisele Olimpio
    de Andrade, Jailson Bittencourt
    MICROCHEMICAL JOURNAL, 2011, 99 (02) : 303 - 308
  • [48] QuEChERS method combined with GC-MS for pesticide residues determination in water
    Ghani, Sherif B. Abdel
    Hanafi, Ahmad H.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 71 (05) : 508 - 512
  • [49] Zebra GC: A mini gas chromatography system for trace-level determination of hazardous air pollutants
    Garga, Apoorva
    Akbar, Muhammad
    Vejerano, Eric
    Narayanan, Shree
    Nazhandali, Leyla
    Marr, Linsey C.
    Agah, Masoud
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 212 : 145 - 154
  • [50] Lowering Detection Limits for 1,4-Dioxane in Drinking Water Using Large Volume Injection in an Unmodified Splitless GC Inlet
    Rattray, Chris
    Cochran, Jack
    English, Chris
    LC GC NORTH AMERICA, 2012, : 22 - 24