Trace-level determination of 1,4-dioxane in water by isotopic dilution GC and GC-MS

被引:40
|
作者
Draper, WM [1 ]
Dhoot, JS [1 ]
Remoy, JW [1 ]
Perera, SK [1 ]
机构
[1] Calif Dept Hlth Serv, Sanitat & Radiat Lab Branch, Berkeley, CA 94704 USA
关键词
D O I
10.1039/b002345k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The volatile and polar solvent 1,4-dioxane has recently been reported as a contaminant of ground and surface waters, establishing the need to determine this substance in drinking water. This investigation established that 1,4-dioxane can be determined in water by various techniques including direct aqueous injection (DAI) gas chromatography (GC) and purge and trap GC-mass spectrometry (MS). Purge and trap GC-MS is limited by 1,4-dioxane's poor purge efficiency, resulting in detection limits up to 100 times greater than the efficiently purged volatile organic compounds. To attain the sensitivity required for drinking water monitoring, a method based on continuous liquid-liquid extraction with dichloromethane was developed. Isotope dilution was more accurate and reproducible than quantification with external standards, and the improvement in precision led to a lower method detection limit, 0.2 mu g L-1, using a quadrupole ion trap instrument in the electron ionization mode. Isotope dilution accuracy approached 100% in ppb determinations. Isotopic dilution quantification was also possible using a non-selective GC detector owing to the high efficiency of capillary GC columns that resolve the deuterium-labeled solvent from the natural isotopes.
引用
收藏
页码:1403 / 1408
页数:6
相关论文
共 50 条
  • [31] Solid-Phase Microextraction (SPME) and Triple Quadrupole Gas Chromatography (GC-MS- MS) - Simultaneous Analysis of VOCs and 1,4-Dioxane in Water
    Egli, Christine
    Pfister, Rolf
    Moffatt, Lorna
    Kelting, Rebecca
    LC GC EUROPE, 2014, 27 (12) : 674 - 674
  • [32] Determination of selenomethionine in yeast using CNBr derivatization and species specific isotope dilution GC ICP-MS and GC-MS
    Yang, L
    Sturgeon, RE
    Wolf, WR
    Goldschmidt, RJ
    Mester, Z
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (11) : 1448 - 1453
  • [33] The Determination of Galaxolide in Water Samples with SPME Coupled with GC-MS
    Su, Bi Dong
    Min, Chen Zhen
    Hui, Chen Dong
    ENVIRONMENTAL BIOTECHNOLOGY AND MATERIALS ENGINEERING, PTS 1-3, 2011, 183-185 : 184 - 187
  • [34] Simultaneous capillary GC-MS determination of triazines and amides in water
    Hu, R
    Berthion, JM
    Bodereau, I
    Fournier, J
    CHROMATOGRAPHIA, 1996, 43 (3-4) : 181 - 186
  • [35] Application of experimental design to the determination of pesticides in water by GC-MS
    Fournier, JB
    El Hourch, M
    Taglioni, JP
    Fournier, J
    ANALUSIS, 1998, 26 (08) : M44 - M52
  • [36] Determination of dichloroanilines in human urine by GC-MS, GC-MS-MS, and GC-ECD as markers of low-level pesticide exposure
    Wittke, K
    Hajimiragha, H
    Dunemann, L
    Begerow, J
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2001, 755 (1-2): : 215 - 228
  • [37] Determination of 18 polycyclic aromatic hydrocarbons in edible oils by isotope dilution GC-MS/MS
    Beijing Key Laboratory of Environmentally Harmful Chemical Analysis, Beijing University of Chemical Technology, Beijing
    100029, China
    不详
    100013, China
    J. Chin. Mass Spectrom. Soc., 2 (120-127):
  • [38] CONCURRENT DETERMINATION OF 1,4-DIOXANE AND NITROSAMINE CONTAMINANTS IN DRINKING WATER
    Rattray, Chris
    Cochran, Jack
    CHEMICAL & ENGINEERING NEWS, 2015, : 14 - 16
  • [39] Ultra trace level determinations of acrylamide in surface and drinking water by GC-MS after derivatization with xanthydrol
    Lim, Hyun-Hee
    Shin, Ho-Sang
    JOURNAL OF SEPARATION SCIENCE, 2013, 36 (18) : 3059 - 3066
  • [40] TRIBUTYLTIN DETECTION AT TRACE LEVELS IN WATER AND SEDIMENTS USING GC WITH FLAME-PHOTOMETRIC DETECTION AND GC-MS
    MUELLER, MD
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1984, 317 (01): : 32 - 36