Mathematical Modeling of Rotary Blood Pumps in a Pulsatile In Vitro Flow Environment

被引:10
|
作者
Pirbodaghi, Tohid [1 ]
机构
[1] Univ Bern, Murtenstr 50, CH-3010 Bern, Switzerland
关键词
Rotary blood pumps; In-vitro study; Dynamic identification; HEAD ESTIMATION; PRESSURE-HEAD; MODULATION;
D O I
10.1111/aor.12860
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Nowadays, sacrificing animals to develop medical devices and receive regulatory approval has become more common, which increases ethical concerns. Although in vivo tests are necessary for development and evaluation of new devices, nonetheless, with appropriate in vitro setups and mathematical models, a part of the validation process can be performed using these models to reduce the number of sacrificed animals. The main aim of this study is to present a mathematical model simulating the hydrodynamic function of a rotary blood pump (RBP) in a pulsatile in vitro flow environment. This model relates the pressure head of the RBP to the flow rate, rotational speed, and time derivatives of flow rate and rotational speed. To identify the model parameters, an in vitro setup was constructed consisting of a piston pump, a compliance chamber, a throttle, a buffer reservoir, and the CentriMag RBP. A 40% glycerin-water mixture as a blood analog fluid and deionized water were used in the hydraulic circuit to investigate the effect of viscosity and density of the working fluid on the model parameters. First, model variables were physically measured and digitally acquired. Second, an identification algorithm based on regression analysis was used to derive the model parameters. Third, the completed model was validated with a totally different set of in vitro data. The model is usable for both mathematical simulations of the interaction between the pump and heart and indirect pressure measurement in a clinical context.
引用
收藏
页码:710 / 716
页数:7
相关论文
共 50 条
  • [41] The Evolution of Durable, Implantable Axial-Flow Rotary Blood Pumps
    Smith, P. Alex
    Wang, Yaxin
    Frazier, O. H.
    TEXAS HEART INSTITUTE JOURNAL, 2023, 50 (02)
  • [42] Suitable hemolysis index for low-flow rotary blood pumps
    Takashi Yamane
    Kazuki Adachi
    Ryo Kosaka
    Osamu Maruyama
    Masahiro Nishida
    Journal of Artificial Organs, 2021, 24 : 120 - 125
  • [43] The Evolution of Durable, Implantable Axial-Flow Rotary Blood Pumps
    Smith, P. Alex
    Wang, Yaxin
    Frazier, O. H.
    ZEITGESCHICHTE, 2023, 50 (01)
  • [44] Suitable hemolysis index for low-flow rotary blood pumps
    Yamane, Takashi
    Adachi, Kazuki
    Kosaka, Ryo
    Maruyama, Osamu
    Nishida, Masahiro
    JOURNAL OF ARTIFICIAL ORGANS, 2021, 24 (02) : 120 - 125
  • [45] Mechanical Blood-Immersed Bearings in Continuous-Flow Rotary Blood Pumps
    Ranganath, Neel K.
    Rashidi, Majid
    Antaki, James F.
    Phillips, Katherine G.
    Kon, Zachary N.
    Smith, Deane E.
    Reyentovich, Alex
    Moazami, Nader
    ASAIO JOURNAL, 2020, 66 (04) : 343 - 347
  • [46] \Analysis of Pressure Head-Flow Loops of Pulsatile Rotodynamic Blood Pumps
    Jahren, Silje E.
    Ochsner, Gregor
    Shu, Fangjun
    Amacher, Raffael
    Antaki, James F.
    Vandenberghe, Stijn
    ARTIFICIAL ORGANS, 2014, 38 (04) : 316 - 326
  • [47] Comparative analysis of cardiac mechano-energetics in isolated hearts supported by pulsatile or rotary blood pumps
    Granegger, Marcus
    Choi, Young
    Locher, Benedikt
    Aigner, Philipp
    Hubmann, Emanuel J.
    Lemme, Frithjof
    Cesarovic, N. Ikola
    Huebler, Michael
    Schweiger, Martin
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [48] Comparative analysis of cardiac mechano-energetics in isolated hearts supported by pulsatile or rotary blood pumps
    Marcus Granegger
    Young Choi
    Benedikt Locher
    Philipp Aigner
    Emanuel J. Hubmann
    Frithjof Lemme
    Nikola Cesarovic
    Michael Hübler
    Martin Schweiger
    Scientific Reports, 9
  • [49] Unloading effect of a rotary blood pump assessed by mathematical modeling
    Vandenberghe, S
    Segers, P
    Meyns, B
    Verdonck, P
    ARTIFICIAL ORGANS, 2003, 27 (12) : 1094 - 1101
  • [50] Standardized Comparison of Selected Physiological Controllers for Rotary Blood Pumps: In Vitro Study
    Petrou, Anastasios
    Lee, Jongseok
    Dual, Seraina
    Ochsner, Gregor
    Meboldt, Mirko
    Daners, Marianne Schmid
    ARTIFICIAL ORGANS, 2018, 42 (03) : E29 - E42