Mathematical Modeling of Rotary Blood Pumps in a Pulsatile In Vitro Flow Environment

被引:10
|
作者
Pirbodaghi, Tohid [1 ]
机构
[1] Univ Bern, Murtenstr 50, CH-3010 Bern, Switzerland
关键词
Rotary blood pumps; In-vitro study; Dynamic identification; HEAD ESTIMATION; PRESSURE-HEAD; MODULATION;
D O I
10.1111/aor.12860
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Nowadays, sacrificing animals to develop medical devices and receive regulatory approval has become more common, which increases ethical concerns. Although in vivo tests are necessary for development and evaluation of new devices, nonetheless, with appropriate in vitro setups and mathematical models, a part of the validation process can be performed using these models to reduce the number of sacrificed animals. The main aim of this study is to present a mathematical model simulating the hydrodynamic function of a rotary blood pump (RBP) in a pulsatile in vitro flow environment. This model relates the pressure head of the RBP to the flow rate, rotational speed, and time derivatives of flow rate and rotational speed. To identify the model parameters, an in vitro setup was constructed consisting of a piston pump, a compliance chamber, a throttle, a buffer reservoir, and the CentriMag RBP. A 40% glycerin-water mixture as a blood analog fluid and deionized water were used in the hydraulic circuit to investigate the effect of viscosity and density of the working fluid on the model parameters. First, model variables were physically measured and digitally acquired. Second, an identification algorithm based on regression analysis was used to derive the model parameters. Third, the completed model was validated with a totally different set of in vitro data. The model is usable for both mathematical simulations of the interaction between the pump and heart and indirect pressure measurement in a clinical context.
引用
收藏
页码:710 / 716
页数:7
相关论文
共 50 条
  • [31] Investigation of Blood Hemolysis Study in Rotary Blood Pump between Continuous Flow and Pulsatile Flow
    Rungsirikunnan, Chitsanupong
    Mondee, Kamonwan
    Gesprasert, Goragoch
    Naiyanetr, Phornphop
    2018 11TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2018), 2018,
  • [32] Blood flow estimation of pulsatile Extracoporeal Life Support System with minimal measurement and mathematical modeling
    不详
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2005, 28 (09): : 947 - 947
  • [33] Mathematical Modeling of Blood Flow
    Rahmani, Md. Shoaibur
    Haque, Md. Aynal
    2012 INTERNATIONAL CONFERENCE ON INFORMATICS, ELECTRONICS & VISION (ICIEV), 2012, : 672 - 676
  • [34] IN VITRO AND IN VIVO FLOW STUDIES IN BLOOD PUMPS
    LIOTTA, D
    WIETING, DW
    HALL, CW
    GHIDONI, JJ
    DEBAKEY, ME
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1967, 13 (APR): : 280 - &
  • [35] Speed Modulation of the HeartWare HVAD to Assess In Vitro Hemocompatibility of Pulsatile and Continuous Flow Regimes in a Rotary Blood Pump
    Horobin, Jarod T.
    Simmonds, Michael J.
    Nandakumar, Deepika
    Gregory, Shaun D.
    Tansley, Geoff
    Pauls, Jo P.
    Girnghuber, Angela
    Balletti, Nicoletta
    Fraser, John F.
    ARTIFICIAL ORGANS, 2018, 42 (09) : 879 - 890
  • [36] BIOMATERIALS FOR ROTARY BLOOD PUMPS
    VANOEVEREN, W
    ARTIFICIAL ORGANS, 1995, 19 (07) : 603 - 607
  • [37] Bearing of rotary blood pumps
    Nishida, Masahiro
    Toraibarojisuto/Journal of Japanese Society of Tribologists, 2015, 60 (12): : 771 - 777
  • [38] Progress of rotary blood pumps
    Takatani, S
    ARTIFICIAL ORGANS, 2006, 30 (05) : 317 - 321
  • [39] VOLUME COMPENSATION FOR PULSATILE BLOOD PUMPS
    WHALEN, RL
    SNOW, JL
    HARASAKI, H
    NOSE, Y
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1981, 27 : 110 - 115
  • [40] Comparison of Flow Estimators for Rotary Blood Pumps: An In Vitro and In Vivo Study (vol 46, pg 2123, 2018)
    Petrou, Anastasios
    Kuster, Daniel
    Lee, Jongseok
    Meboldt, Mirko
    Daners, Marianne Schmid
    ANNALS OF BIOMEDICAL ENGINEERING, 2019, 47 (08) : 1827 - 1827