3D Catheter Guidance including Shape Sensing for Endovascular Navigation

被引:8
|
作者
Jaeckle, Sonja [1 ]
Garcia-Vazquez, Veronica [2 ]
von Haxthausen, Felix [2 ]
Eixmann, Tim [3 ]
Sieren, Malte Maria [4 ]
Schulz-Hildebrandt, Hinnerk [3 ,5 ,6 ]
Huttmann, Gereon [3 ,5 ,6 ]
Ernst, Floris [2 ]
Kleemann, Markus [7 ]
Paetz, Torben [8 ]
机构
[1] Inst Digital Med, Fraunhofer MEVIS, Lubeck, Germany
[2] Univ Lubeck, Inst Robot & Cognit Syst, Lubeck, Germany
[3] Med Laserzentrum Lubeck GmbH, Lubeck, Germany
[4] UKSH, Dept Radiol & Nucl Med, Lubeck, Germany
[5] Univ Lubeck, Inst Biomed Opt, Lubeck, Germany
[6] DZL, German Ctr Lung Res, Grohansdorf, Germany
[7] UKSH, Dept Surg, Lubeck, Germany
[8] Inst Digital Med, Fraunhofer MEVIS, Bremen, Germany
关键词
catheter guidance; electromagnetic tracking; fiber Bragg gratings; shape sensing; endovascular navigation; endovascular aneurysm repair; ELECTROMAGNETIC TRACKING; ANEURYSM REPAIR;
D O I
10.1117/12.2548094
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Currently, fluoroscopy and conventional digital subtraction angiography are used for imaging guidance in endovascular aortic repair (EVAR) procedures. Drawbacks of these image modalities are X-ray exposure, the usage of contrast agents and the lack of depth information. To overcome these disadvantages, a catheter prototype containing a multicore fiber with fiber Bragg gratings for shape sensing and three electromagnetic (EM) sensors for locating the shape was built in this study. Furthermore, a model for processing the input data from the tracking systems to obtain the located 3D shape of the first 38 cm of the catheter was introduced: A spatial calibration between the optical fiber and each EM sensor was made in a calibration step and used to obtain the located shape of the catheter in subsequent experiments. The evaluation of our shape localization method with the catheter prototype in different shapes resulted in average errors from 0.99 to 2.29 mm and maximum errors from 1.73 to 2.99 mm. The experiments showed that an accurate shape localization with a multicore fiber and three EM sensors is possible, and that this catheter guidance is promising for EVAR procedures. Future work will be focused on the development of catheter guidance based on shape sensing with a multicore fiber, and the orientation and position of less than three EM sensors.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] 3D Indoor Scene Reconstruction and Change Detection for Robotic Sensing and Navigation
    Liu, Ruixu
    Asari, Vijayan K.
    MOBILE MULTIMEDIA/IMAGE PROCESSING, SECURITY, AND APPLICATIONS 2017, 2017, 10221
  • [42] 3D Printing Shape-Changing Devices with Inductive Sensing
    Lee, Hsuanling
    He, Liang
    PROCEEDINGS OF THE SIGGRAPH 2024 POSTERS, 2024,
  • [43] Using 3D printed models for planning and guidance during endovascular intervention: a technical advance
    Itagaki, Michael W.
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2015, 21 (04) : 338 - 341
  • [44] Endovascular Catheter for Magnetic Navigation under MR Imaging Guidance: Evaluation of Safety In Vivo at 1.5T
    Hetts, S. W.
    Saeed, M.
    Martin, A. J.
    Evans, L.
    Bernhardt, A. F.
    Malba, V.
    Settecase, F.
    Do, L.
    Yee, E. J.
    Losey, A.
    Sincic, R.
    Lillaney, P.
    Roy, S.
    Arenson, R. L.
    Wilson, M. W.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (11) : 2083 - 2091
  • [45] A microfluidic device for 2D to 3D and 3D to 3D cell navigation
    Shamloo, Amir
    Amirifar, Leyla
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2016, 26 (01)
  • [46] 3D Visualisation of Navigation Catheters for Endovascular Procedures Using a 3D Hub and Fiber Optic RealShape Technology: Phantom Study Results
    Bydlon, Torre M.
    Torjesen, Alyssa
    Fokkenrood, Steven
    Di Tullio, Alessandra
    Flexman, Molly L.
    EJVES VASCULAR FORUM, 2023, 59 : 24 - 30
  • [47] Femtosecond laser processing of evanescence field coupled waveguides in single mode glass fibers for optical 3D shape sensing and navigation
    Waltermann, Christian
    Baumann, Anna Lena
    Bethmann, Konrad
    Doering, Alexander
    Koch, Jan
    Angelmahr, Martin
    Schade, Wolfgang
    FIBER OPTIC SENSORS AND APPLICATIONS XII, 2015, 9480
  • [48] Fusion of Biplane Fluoroscopy With Fiber Bragg Grating for 3D Catheter Shape Reconstruction
    Ourak, M.
    De Buck, S.
    Ha, X. T.
    Al-Ahmad, O.
    Bamps, K.
    Ector, J.
    Vander Poorten, E.
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2021, 6 (04): : 6505 - 6512
  • [49] 3D Shape Reconstruction Algorithm for Interventional Catheter Based on HPO-BPNN
    Li, Tianliang
    Zhu, Yongwen
    Song, Zhenzhen
    Wang, Bin
    2024 IEEE INTERNATIONAL CONFERENCE ON CYBERNETICS AND INTELLIGENT SYSTEMS, CIS AND IEEE INTERNATIONAL CONFERENCE ON ROBOTICS, AUTOMATION AND MECHATRONICS, RAM, CIS-RAM 2024, 2024, : 63 - 68
  • [50] 3D shape sensing and deep learning-based segmentation of strawberries
    Le Louëdec J.
    Cielniak G.
    Computers and Electronics in Agriculture, 2021, 190