3D Catheter Guidance including Shape Sensing for Endovascular Navigation

被引:8
|
作者
Jaeckle, Sonja [1 ]
Garcia-Vazquez, Veronica [2 ]
von Haxthausen, Felix [2 ]
Eixmann, Tim [3 ]
Sieren, Malte Maria [4 ]
Schulz-Hildebrandt, Hinnerk [3 ,5 ,6 ]
Huttmann, Gereon [3 ,5 ,6 ]
Ernst, Floris [2 ]
Kleemann, Markus [7 ]
Paetz, Torben [8 ]
机构
[1] Inst Digital Med, Fraunhofer MEVIS, Lubeck, Germany
[2] Univ Lubeck, Inst Robot & Cognit Syst, Lubeck, Germany
[3] Med Laserzentrum Lubeck GmbH, Lubeck, Germany
[4] UKSH, Dept Radiol & Nucl Med, Lubeck, Germany
[5] Univ Lubeck, Inst Biomed Opt, Lubeck, Germany
[6] DZL, German Ctr Lung Res, Grohansdorf, Germany
[7] UKSH, Dept Surg, Lubeck, Germany
[8] Inst Digital Med, Fraunhofer MEVIS, Bremen, Germany
关键词
catheter guidance; electromagnetic tracking; fiber Bragg gratings; shape sensing; endovascular navigation; endovascular aneurysm repair; ELECTROMAGNETIC TRACKING; ANEURYSM REPAIR;
D O I
10.1117/12.2548094
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Currently, fluoroscopy and conventional digital subtraction angiography are used for imaging guidance in endovascular aortic repair (EVAR) procedures. Drawbacks of these image modalities are X-ray exposure, the usage of contrast agents and the lack of depth information. To overcome these disadvantages, a catheter prototype containing a multicore fiber with fiber Bragg gratings for shape sensing and three electromagnetic (EM) sensors for locating the shape was built in this study. Furthermore, a model for processing the input data from the tracking systems to obtain the located 3D shape of the first 38 cm of the catheter was introduced: A spatial calibration between the optical fiber and each EM sensor was made in a calibration step and used to obtain the located shape of the catheter in subsequent experiments. The evaluation of our shape localization method with the catheter prototype in different shapes resulted in average errors from 0.99 to 2.29 mm and maximum errors from 1.73 to 2.99 mm. The experiments showed that an accurate shape localization with a multicore fiber and three EM sensors is possible, and that this catheter guidance is promising for EVAR procedures. Future work will be focused on the development of catheter guidance based on shape sensing with a multicore fiber, and the orientation and position of less than three EM sensors.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Evaluation of an Electromagnetic 3D Navigation System to Facilitate Endovascular Tasks: A Feasibility Study
    Sidhu, R.
    Weir-McCall, J.
    Cochennec, F.
    Riga, C.
    DiMarco, A.
    Bicknell, C. D.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2012, 43 (01) : 22 - 29
  • [32] Estimation of 2D/3D rigid transformation for Computer-assisted Endovascular Navigation
    Castro, Miguel
    Goeksu, Cemil
    Haigron, Pascal
    Lucas, Antoine
    Urbano, Luis
    2008 3RD INTERNATIONAL CONFERENCE ON INFORMATION AND COMMUNICATION TECHNOLOGIES: FROM THEORY TO APPLICATIONS, VOLS 1-5, 2008, : 1099 - +
  • [33] Energy Based 3D Autopilot for VTOL UAV Under Guidance & Navigation Constraints
    Bouzid, Y.
    Siguerdidjane, H.
    Bestaoui, Y.
    Zareb, M.
    JOURNAL OF INTELLIGENT & ROBOTIC SYSTEMS, 2017, 87 (02) : 341 - 362
  • [34] Energy Based 3D Autopilot for VTOL UAV Under Guidance & Navigation Constraints
    Y. Bouzid
    H. Siguerdidjane
    Y. Bestaoui
    M. Zareb
    Journal of Intelligent & Robotic Systems, 2017, 87 : 341 - 362
  • [35] Image Thickness Correction for Navigation with 3D Intra-cardiac Ultrasound Catheter
    Zhong, Hua
    Kanade, Takeo
    Schwartzman, David
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2008, PT II, PROCEEDINGS, 2008, 5242 : 485 - 492
  • [36] 3D navigation in medicine
    Haigron, P
    LeBerre, G
    Coatrieux, JL
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1996, 15 (02): : 70 - 78
  • [37] 3D Scatterplot Navigation
    Sanftmann, Harald
    Weiskopf, Daniel
    IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS, 2012, 18 (11) : 1969 - 1978
  • [38] Safe 3D Navigation
    Fitzmaurice, George
    Matejka, Justin
    Mordatch, Igor
    Khan, Azam
    Kurtenbach, Gordon
    I3D 2008: SYMPOSIUM ON INTERACTIVE 3D GRAPHICS AND GAMES, PROCEEDINGS, 2008, : 7 - 15
  • [39] The mechanics and dynamics of cancer cells sensing noisy 3D contact guidance
    Kim, Jihan
    Cao, Yuansheng
    Eddy, Christopher
    Deng, Youyuan
    Levine, Herbert
    Rappel, Wouter-Jan
    Sun, Bo
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2021, 118 (10)
  • [40] 3D Change Detection in Staggered Voxels Model for Robotic Sensing and Navigation
    Liu, Ruixu
    Hampshire, Brandon
    Asari, Vijiayan K.
    MOBILE MULTIMEDIA/IMAGE PROCESSING, SECURITY, AND APPLICATIONS 2016, 2016, 9869