3D Catheter Guidance including Shape Sensing for Endovascular Navigation

被引:8
|
作者
Jaeckle, Sonja [1 ]
Garcia-Vazquez, Veronica [2 ]
von Haxthausen, Felix [2 ]
Eixmann, Tim [3 ]
Sieren, Malte Maria [4 ]
Schulz-Hildebrandt, Hinnerk [3 ,5 ,6 ]
Huttmann, Gereon [3 ,5 ,6 ]
Ernst, Floris [2 ]
Kleemann, Markus [7 ]
Paetz, Torben [8 ]
机构
[1] Inst Digital Med, Fraunhofer MEVIS, Lubeck, Germany
[2] Univ Lubeck, Inst Robot & Cognit Syst, Lubeck, Germany
[3] Med Laserzentrum Lubeck GmbH, Lubeck, Germany
[4] UKSH, Dept Radiol & Nucl Med, Lubeck, Germany
[5] Univ Lubeck, Inst Biomed Opt, Lubeck, Germany
[6] DZL, German Ctr Lung Res, Grohansdorf, Germany
[7] UKSH, Dept Surg, Lubeck, Germany
[8] Inst Digital Med, Fraunhofer MEVIS, Bremen, Germany
关键词
catheter guidance; electromagnetic tracking; fiber Bragg gratings; shape sensing; endovascular navigation; endovascular aneurysm repair; ELECTROMAGNETIC TRACKING; ANEURYSM REPAIR;
D O I
10.1117/12.2548094
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Currently, fluoroscopy and conventional digital subtraction angiography are used for imaging guidance in endovascular aortic repair (EVAR) procedures. Drawbacks of these image modalities are X-ray exposure, the usage of contrast agents and the lack of depth information. To overcome these disadvantages, a catheter prototype containing a multicore fiber with fiber Bragg gratings for shape sensing and three electromagnetic (EM) sensors for locating the shape was built in this study. Furthermore, a model for processing the input data from the tracking systems to obtain the located 3D shape of the first 38 cm of the catheter was introduced: A spatial calibration between the optical fiber and each EM sensor was made in a calibration step and used to obtain the located shape of the catheter in subsequent experiments. The evaluation of our shape localization method with the catheter prototype in different shapes resulted in average errors from 0.99 to 2.29 mm and maximum errors from 1.73 to 2.99 mm. The experiments showed that an accurate shape localization with a multicore fiber and three EM sensors is possible, and that this catheter guidance is promising for EVAR procedures. Future work will be focused on the development of catheter guidance based on shape sensing with a multicore fiber, and the orientation and position of less than three EM sensors.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Improved Catheter Navigation With 3D Electromagnetic Guidance
    Cochennec, Frederic
    Riga, Celia
    Hamady, Mohamad
    Cheshire, Nicholas
    Bicknell, Colin
    JOURNAL OF ENDOVASCULAR THERAPY, 2013, 20 (01) : 39 - 47
  • [2] Improved 3D Catheter Shape Estimation Using Ultrasound Imaging for Endovascular Navigation: A Further Study
    Chen, Fang
    Liu, Jia
    Zhang, Xinran
    Zhang, Daoqiang
    Liao, Hongen
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2020, 24 (12) : 3616 - 3629
  • [3] 3D Catheter Shape Determination for Endovascular Navigation Using a Two-Step Particle Filter and Ultrasound Scanning
    Chen, Fang
    Liu, Jia
    Liao, Hongen
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (03) : 685 - 695
  • [4] Biologically Inspired Catheter for Endovascular Sensing and Navigation
    Sutton, Erin E.
    Fuerst, Bernhard
    Ghotbi, Reza
    Cowan, Noah J.
    Navab, Nassir
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [5] Biologically Inspired Catheter for Endovascular Sensing and Navigation
    Erin E. Sutton
    Bernhard Fuerst
    Reza Ghotbi
    Noah J. Cowan
    Nassir Navab
    Scientific Reports, 10
  • [6] Three-dimensional guidance including shape sensing of a stentgraft system for endovascular aneurysm repair
    Sonja Jäckle
    Verónica García-Vázquez
    Tim Eixmann
    Florian Matysiak
    Felix von Haxthausen
    Malte Maria Sieren
    Hinnerk Schulz-Hildebrandt
    Gereon Hüttmann
    Floris Ernst
    Markus Kleemann
    Torben Pätz
    International Journal of Computer Assisted Radiology and Surgery, 2020, 15 : 1033 - 1042
  • [7] Three-dimensional guidance including shape sensing of a stentgraft system for endovascular aneurysm repair
    Jaeckle, Sonja
    Garcia-Vazquez, Veronica
    Eixmann, Tim
    Matysiak, Florian
    von Haxthausen, Felix
    Sieren, Malte Maria
    Schulz-Hildebrandt, Hinnerk
    Huettmann, Gereon
    Ernst, Floris
    Kleemann, Markus
    Paetz, Torben
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2020, 15 (06) : 1033 - 1042
  • [8] Reconstructing Endovascular Catheter Interaction Forces in 3D using Multicore Optical Shape Sensors
    Heunis, Christoff M.
    Belfiore, Vincenza
    Vendittelli, Marilena
    Misra, Sarthak
    2019 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS), 2019, : 5419 - 5425
  • [9] Characterization of a 3D Printed Endovascular Magnetic Catheter
    Ansari, Mohammad Hasan Dad
    Ha, Xuan Thao
    Ourak, Mouloud
    Borghesan, Gianni
    Iacovacci, Veronica
    Vander Poorten, Emmanuel
    Menciassi, Arianna
    ACTUATORS, 2023, 12 (11)
  • [10] Catheter navigation support for mechanical thrombectomy guidance: 3D/2D multimodal catheter-based registration with no contrast dye fluoroscopy
    Aurélien de Turenne
    François Eugène
    Raphaël Blanc
    Jérôme Szewczyk
    Pascal Haigron
    International Journal of Computer Assisted Radiology and Surgery, 2024, 19 : 459 - 468