Recent studies with a combined PET/CT scanner

被引:0
|
作者
Townsend, DW [1 ]
Beyer, T [1 ]
Kinahan, PE [1 ]
Charron, M [1 ]
Dachille, M [1 ]
Meltzer, C [1 ]
Brun, T [1 ]
Jerin, J [1 ]
Byars, LG [1 ]
Nutt, R [1 ]
机构
[1] Univ Pittsburgh, Dept Radiol, PET Facil, Pittsburgh, PA 15213 USA
关键词
anatomy; FDG PET; function; fused images; oncology;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background. Coregistration of anatomical (CT) and functional (PET) images for whole-body oncology is complicated by differences in patient positioning, displacement of abdominal organs, and respiration. Methods. A combined PET/CT tomograph with the unique capability to acquire coregistered functional and anatomical images has been designed and built. The PET/CT scanner comprises a Siemens Somatom AR.SP spiral CT and a partial ring, rotating ECAT ART PET scanner. The CT images are used to correct the PET data for scatter and attenuation. Fully quantitative whole-body images are, therefore, obtained for an axial extent of 100 cm in an imaging time of less than 1 h. Results. Over 70 patients have been imaged on the combined scanner. A range of different cancers have been studied, including lung, esophageal, head and neck, melanoma, lymphoma, pancreas and renal cell. The aligned PET and CT images an used both for diagnosis and staging of disease and for evaluating response to therapy. Conclusion. A combined PET and CT scanner is a practical and effective approach to acquiring coregistered anatomical and functional images in a single scanning session. This approach potentially offers improvements in diagnosis and staging of disease, monitoring of therapy, biopsy sampling procedures, and radiation therapy treatment planning.
引用
收藏
页码:229 / 244
页数:16
相关论文
共 50 条
  • [11] Attenuation correction for a combined 3D PET/CT scanner
    Kinahan, PE
    Townsend, DW
    Beyer, T
    Sashin, D
    MEDICAL PHYSICS, 1998, 25 (10) : 2046 - 2053
  • [12] A combined micro-PET/CT scanner for small animal imaging
    Jan, Meei-Ling
    Ni, Yu-Ching
    Chen, Kuo-Wei
    Liang, Hsing-Ching
    Chuang, Keh-Shih
    Fu, Ying-Kai
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (02): : 314 - 318
  • [13] Whole-body FDG PET and CT imaging of malignancies using a combined PET CT scanner.
    Charron, M
    Beyer, T
    Kinahan, PE
    Meltzer, CC
    Dachille, MA
    Townsend, DW
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 256P - 256P
  • [14] Studies of the interactions of an MRI system with the shielding in a combined PET/MRI scanner
    Peng, Bo J.
    Walton, Jeffrey H.
    Cherry, Simon R.
    Willig-Onwuachi, Jacob
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (01): : 265 - 280
  • [15] First clinical oncology experience with a new combined PET/CT scanner positrace®.
    Devillers, A
    Garin, E
    Laffont, S
    Nguyen, T
    Herry, JY
    Chatal, JF
    Bourguet, P
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 309P - 310P
  • [16] Impact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner
    Ehab M. Kamel
    Cyrill Burger
    Alfred Buck
    Gustav K. von Schulthess
    Gerhard W. Goerres
    European Radiology, 2003, 13 : 724 - 728
  • [17] Impact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner
    Kamel, EM
    Burger, C
    Buck, A
    von Schulthess, GK
    Goerres, GW
    EUROPEAN RADIOLOGY, 2003, 13 (04) : 724 - 728
  • [18] Fusion imaging for whole-body oncology with a combined PET and CT scanner.
    Townsend, DW
    Beyer, T
    Kinahan, PE
    Charron, M
    Meltzer, CC
    Dachille, MA
    Jerin, J
    Brun, T
    Roddy, R
    Nutt, R
    Byars, LG
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 148P - 148P
  • [19] CT findings from a PET/CT scanner assessment
    Vaz, T. F.
    Costa, D. C.
    Parafita, R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S510 - S510
  • [20] Quantitative Accuracy in Cardiac Studies with the GE Discovery RX PET/CT Scanner
    Spinks, T. J.
    Bastin, J. E.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2972 - 2976