Comparison of two different screw trajectories in the treatment of oblique scaphoid fractures: A mechanical study on composite bone models

被引:5
|
作者
Kilic, Bulent [1 ]
Caliskan, Mustafa [1 ]
Agar, Anil [1 ]
Uzun, Bora [2 ]
Ertem, Fatih [2 ]
Gulabi, Deniz [1 ]
Erturk, Cemil [1 ]
机构
[1] Univ Hlth Sci, Istanbul Kanuni Sultan Suleyman Training & Res Ho, Dept Orthoped & Traumatol, Istanbul, Turkey
[2] Dokuz Eylul Univ, Sch Med, Dept Biomech, Izmir, Turkey
来源
JOINT DISEASES AND RELATED SURGERY | 2021年 / 32卷 / 02期
关键词
Biomechanics; oblique scaphoid fractures; screw fixation; transverse fracture; FINITE-ELEMENT-ANALYSIS; OPTIMAL FIXATION; WAIST;
D O I
10.52312/jdrs.2021.15
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: In this mechanical study, we aimed to compare two different screw trajectories in terms of durability against axial loads on oblique scaphoid fractures using composite bone models.& nbsp; Materials and methods: Oblique osteotomies were made along the dorsal sulcus of 14 composite scaphoid bone models. Following this, all bone models were randomly classified. One group of bones were fixed with a screw placed perpendicular to the osteotomy line and the other group was fixed with a screw placed centrally down the long axis of the scaphoid bone. Each scaphoid bone model was positioned on a mechanical testing machine. Subsequently, axial loading tests were applied on each bone model to measure the amount of loading required to cause 2-mm displacement and failure on the osteotomy side and maximum displacement at the time of failure on scaphoid bone models.& nbsp; Results: There was no statistically significant difference in load to 2-mm displacement and failure between the two groups (p>0.05). Also, there was no statistically significant difference between the two groups in terms of maximum displacement seen on failure (p>0.05).& nbsp; Conclusion: In our study, we found that the stability of the screws which laid perpendicular to the fracture line and parallel to the long axis of the scaphoid was the same in fixing oblique scaphoid fractures.
引用
收藏
页码:377 / 382
页数:6
相关论文
共 50 条
  • [31] Pull-out forces of headless compression screws in variations of synthetic bone models imitating different types of scaphoid fractures in good bone quality
    Erhart, Jochen
    Unger, Ewald
    Trulson, Inga
    Hagmann, Michael
    Ristl, Robin
    Trulson, Alexander
    Hajdu, Stefan
    Schefzig, Philip
    Gormasz, Anna
    Mayr, Winfried
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2020, 31 (11)
  • [32] Pull-out forces of headless compression screws in variations of synthetic bone models imitating different types of scaphoid fractures in good bone quality
    Jochen Erhart
    Ewald Unger
    Inga Trulson
    Michael Hagmann
    Robin Ristl
    Alexander Trulson
    Stefan Hajdu
    Philip Schefzig
    Anna Gormasz
    Winfried Mayr
    Journal of Materials Science: Materials in Medicine, 2020, 31
  • [33] Biomechanical comparison of three different compression screws for treatment of odontoid fractures evaluation of a new screw design
    Mueller, Jan-Uwe
    Mueller, Jonas
    Marx, Sascha
    Matthes, Marc
    Nowak, Stephan
    Schroeder, Henry Werner Siegfried
    Pillich, Dirk Thomas
    CLINICAL BIOMECHANICS, 2020, 77
  • [34] Treatment of Scaphoid Waist Nonunions with an Avascular Proximal Pole and Carpal Collapse A Comparison of Two Vascularized Bone Grafts
    Jones, David B., Jr.
    Buerger, Heinz
    Bishop, Allen T.
    Shin, Alexander Y.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (12): : 2616 - 2625
  • [35] Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or a 95° screw-plate -: A prospective, randomized study
    Sadowski, C
    Lübbeke, A
    Saudan, M
    Riand, N
    Stern, R
    Hoffmeyer, P
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (03): : 372 - 381
  • [36] The Comparison of Dynamic Condylar Screw Plate to Proximal Femoral Nail in Reverse Oblique and Transverse Intertrochanteric Fractures: A Retrospective Study on 61 Patients
    Sensoez, Ersin
    Ergun, Selim
    Kayaalp, Mahmut Enes
    Eceviz, Engin
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (03)
  • [37] A COMPARISON OF THE USE OF DISTAL RADIUS VASCULARISED BONE GRAFT AND NON-VASCULARISED ILIAC CREST BONE GRAFT IN THE TREATMENT OF NON-UNION OF SCAPHOID FRACTURES
    Braga-Silva, J.
    Peruchi, F. M.
    Moschen, G. M.
    Gehlen, D.
    Padoin, A. V.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2008, 33E (05) : 636 - 640
  • [38] Functional and radiologic outcomes of non-displaced scaphoid waist fractures in adolescents approaching skeletal maturity: Comparison between conservative treatment and percutaneous screw fixation
    Andre, Constance
    Coursier, Raphael
    Saab, Marc
    Mezel, Aurelie
    Nectoux, Eric
    Fron, Damien
    Pouges, Cecile
    Canavese, Federico
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2024, 110 (06)
  • [39] Operative versus conservative treatment of non-displaced fractures of the scaphoid bone. Results of a controlled multicenter cohort study
    Schaedel-Hoepfner, M.
    Marent-Huber, M.
    Sauerbier, M.
    Pillukat, T.
    Eisenschenk, A.
    Siebert, H. R.
    UNFALLCHIRURG, 2010, 113 (10): : 804 - +
  • [40] A retrospective study on the treatment of bone fractures in 14 wild birds of different species and ages by bone muffs
    Unsaldi, Sami
    Unsaldi, Esin
    VETERINARSKI ARHIV, 2023, 93 (03) : 367 - 380