Biomechanical comparison of three different compression screws for treatment of odontoid fractures evaluation of a new screw design

被引:3
|
作者
Mueller, Jan-Uwe [1 ]
Mueller, Jonas [1 ]
Marx, Sascha [1 ]
Matthes, Marc [1 ]
Nowak, Stephan [1 ]
Schroeder, Henry Werner Siegfried [1 ]
Pillich, Dirk Thomas [1 ]
机构
[1] Univ Med Greifswald, Dept Neurosurg, F Sauerbruch Str, D-17475 Greifswald, Germany
关键词
COMPUTED TOMOGRAPHIC EVALUATION; PULLOUT STRENGTH; CORTICAL BONE; INSERTION TORQUE; THREAD DESIGN; HOLDING-POWER; FIXATION; DENSITY;
D O I
10.1016/j.clinbiomech.2020.105049
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Lag screw osteosynthesis in odontoid fractures shows a high rate of pseudarthrosis. Biomechanical properties may play a role with insufficient fragment compression or unnoticed screw stripping. A biomechanical comparison of different constructed lag-screws was carried out and the biomechanical properties determined. Methods: Two identical compression screws with different pilot holes (1.25 and 2.5 mm), a double-threaded screw and one sleeve-nut-screw were tested on artificial bone (Sawbone, densities 10-30pcf). Fragment compression and torque were continuously measured using thin-film force sensors (Flexiforce A201, Tekscan) and torque sensors (PCE-TM 80, PCE GmbH). Findings: The lowest compression reached the double-threaded screw. Compression and sleeve-nut-screw achieved 214-298% and 325-546%, respectively, of the compression force of double-threaded-screw, depending on the test material. The pilot hole optimization led to a significant improvement in compression only in the densest test material. Screw stripping took place significantly later with increasing density of the test material on all screws. In compression screws this was done at a screw rotation of 180-270 degrees, in sleeve nut screw at 270-720 degrees and in double-threaded screws at 300-600 degrees after reaching the maximum compression. Interpretation: Double-threaded screw is robust against screw stripping, but achieves only low fragment compression. The classic compression screws achieve better compression, but are sensitive to screw stripping. Sleeve-nut screw is superior in compression and as robust as double-threaded screw against screw stripping. Whether the better biomechanical properties lead to a reduction in pseudarthrosis must be proven in clinical trials.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Biomechanical comparison of two different compression screws for the treatment of odontoid fractures in human dens axis specimen.
    Mueller, Jan-Uwe
    Nowak, Stephan
    Matthes, Marc
    Pillich, Dirk Thomas
    Schroeder, Henry Werner Siegfried
    Schroeder, Siegfried
    Mueller, Jonas
    CLINICAL BIOMECHANICS, 2024, 111
  • [2] Biomechanical evaluation of four different posterior screw and rod fixation techniques for the treatment of the odontoid fractures
    Li, Lei
    Liu, Wen-Fei
    Jiang, Hong-Kun
    Li, Yun-Peng
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (06): : 8571 - 8580
  • [3] Biomechanical comparison of headless compression screws versus independent locking screw for intra-articular fractures
    Mandala, Meghana
    Shaunak, Shalin
    Kreitmair, Paul
    Phadnis, Joideep
    Guryel, Enis
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (03): : 1319 - 1325
  • [4] Biomechanical comparison of headless compression screws versus independent locking screw for intra-articular fractures
    Meghana Mandala
    Shalin Shaunak
    Paul Kreitmair
    Joideep Phadnis
    Enis Guryel
    European Journal of Orthopaedic Surgery & Traumatology, 2024, 34 : 1319 - 1325
  • [6] Osteosynthesis of Phalangeal Fractures: Biomechanical Comparison of Kirschner Wires, Plates, and Compression Screws
    Rausch, Valentin
    Harbrecht, Andreas
    Kahmann, Stephanie L.
    Fenten, Thomas
    Jovanovic, Nebojsa
    Hackl, Michael
    Mueller, Lars P.
    Staat, Manfred
    Wegmann, Kilian
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2020, 45 (10): : 987.e1 - 987.e8
  • [7] Biomechanical Comparison of Inter-fragmentary Compression Pressures : Lag Screw versus Herbert Screw for Anterior Odontoid Screw Fixation
    Park, Jin-Woo
    Kim, Kyoung-Tae
    Sung, Joo-Kyung
    Park, Seong-Hyun
    Seong, Ki-Woong
    Cho, Dae-Chul
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2017, 60 (05) : 498 - 503
  • [8] Screw fixation of radial head fractures: Compression screw versus lag screw-A biomechanical comparison
    Burkhart, Klaus J.
    Nowak, Tobias E.
    Appelmann, Philipp
    Sternstein, Werner
    Rommens, Pol M.
    Mueller, Lars P.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (10): : 1015 - 1019
  • [9] Biomechanical comparison of antirotator compression hip screw and cannulated screw fixations in the femoral neck fractures
    Saglam, Necdet
    Kucukdurmaz, Fatih
    Kivilcim, Hakan
    Kurtulmus, Tuhan
    Sen, Cengiz
    Akpinar, Fuat
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2014, 48 (02) : 196 - 201
  • [10] Pedicle screw instrumentation of thoracolumbar burst fractures: Biomechanical evaluation of screw configuration with pedicle screws at the level of the fracture
    Bolesta, Michael J.
    Caron, Troy
    Chinthakunta, Suresh R.
    Vazifeh, Pedram Niknam
    Khalil, Saif
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2012, 6 : 200 - 205