Biomechanical Comparison of 2 Double Plating Methods in a Coronal Fracture Model of Bicondylar Tibial Plateau Fractures

被引:2
|
作者
Samsami, Shabnam [1 ]
Patzold, Robert [2 ,3 ]
Neuy, Tim [4 ]
Greinwald, Markus [2 ]
Muller, Peter E. [5 ]
Chevalier, Yan [5 ]
Puschel, Klaus [6 ]
Augat, Peter [2 ,7 ]
机构
[1] Imperial Coll London, Dept Mech Engn, South Kensington Campus, London SW7 2AZ, England
[2] Berufsgenossenschaftl Unfallklin, Dept Inst Biomech, Murnau, Germany
[3] Berufsgenossenschaftl Unfallklin, Dept Trauma Surg, Murnau, Germany
[4] Paracelsus Med Univ, Med Dept, Salzburg, Austria
[5] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Orthopaed Phys Med & Rehabil, Munich, Germany
[6] Univ Med Ctr Hamburg Eppendorf, Dept Forens Med, Hamburg, Germany
[7] Paracelsus Med Univ, Dept Inst Biomech, Salzburg, Austria
关键词
bicondylar tibial plateau fracture; posteromedial fracture fragment; coronal fracture model; double plating osteosynthesis; mechanical test; interfragmentary movement; LESS INVASIVE STABILIZATION; POSTEROMEDIAL FRAGMENT; INTERNAL-FIXATION; REDUCTION; CLASSIFICATION; MORPHOLOGY; LOCKING; SINGLE;
D O I
10.1097/BOT.0000000000002257
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: Because management of bicondylar tibial plateau fractures are complicated even for expert surgeons, with using a coronal fracture model, we aimed to compare 2 kinds of double locked plating techniques that consisted of the lateral locking plate and the medial locking plate inserted medial anteriorly (MA-ly) or medial posteriorly (MP-ly). Methods: Fourteen fresh-frozen tibias stabilized with the MA or MP methods were allocated into 2 groups with similar bone mineral density values. Implanted samples were tested under incremental fatigue loading conditions using a customized load applicator. An optical motion tracking system was used to assess relative displacements and rotations of fracture fragments during loading. Static and dynamic global stiffness, failure load, failure cycles, as well as movements of fracture fragments were measured. Results: There were no significant differences between the 2 fixation methods regarding global stiffness, failure load, or failure cycles (P = 0.67-0.98, depending on the parameter). The kinematic evaluations, however, revealed that different positions of the medial locking plates altered the directions of movements for the medial-anterior or medial-posterior fracture segments. Conclusions: The mechanical stability of tibia-implant constructs fixed with the double plating methods was not remarkably affected by the location of the medial locking plate. Depending on clinical conditions and surgeons' preferences, bicondylar tibial plateau fractures can be managed with either MA or MP methods.
引用
收藏
页码:E129 / E135
页数:7
相关论文
共 50 条
  • [31] Experimental model of tibial plateau fracture for biomechanical testing
    Ali, Ahmad M.
    Saleh, Michael
    Bolongaro, Stefano
    Yang, Lang
    JOURNAL OF BIOMECHANICS, 2006, 39 (07) : 1355 - 1360
  • [32] Pathoanatomy and incidence of the posterolateral fractures in bicondylar tibial plateau fractures: a clinical computed tomography-based measurement and the associated biomechanical model simulation
    Zhu, Yi
    Meili, Severin
    Dong, Ming-Jie
    Zhai, Qi-Lin
    Yao, Lin
    Wang, Jing-Chao
    Hu, Cheng-Fang
    Sun, Hui
    Luo, Cong-Feng
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2014, 134 (10) : 1369 - 1380
  • [33] Biomechanical aspects of the posteromedial split in bicondylar tibial plateau fractures-a finite-element investigation
    Dehoust, J.
    Muench, M.
    Seide, K.
    Barth, T.
    Frosch, K. -H.
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2020, 46 (06) : 1257 - 1266
  • [34] Pathoanatomy and incidence of the posterolateral fractures in bicondylar tibial plateau fractures: a clinical computed tomography-based measurement and the associated biomechanical model simulation
    Yi Zhu
    Severin Meili
    Ming-Jie Dong
    Qi-Lin Zhai
    Lin Yao
    Jing-Chao Wang
    Cheng-Fang Hu
    Hui Sun
    Cong-Feng Luo
    Archives of Orthopaedic and Trauma Surgery, 2014, 134 : 1369 - 1380
  • [35] Less invasive stabilization of complex tibial plateau fractures -: A biomechanical evaluation of a unilateral locked screw plate and double plating
    Gösling, T
    Schandelmaier, P
    Marti, A
    Hufner, T
    Partenheimer, A
    Krettek, C
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (08) : 546 - 551
  • [36] A comparative study of Less Invasive Stabilization System (LISS) fixation and two-incision double plating for the treatment of bicondylar tibial plateau fractures
    Jiang, Rui
    Luo, Cong-Feng
    Wang, Ming-Chun
    Yang, Tie-Yi
    Zeng, Bing-Fang
    KNEE, 2008, 15 (02): : 139 - 143
  • [37] Comparison of Outcomes of Operatively Treated Bicondylar Tibial Plateau Fractures by External Fixation and Internal Fixation
    Chan, C. C.
    Keating, J.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2012, 6 (01) : 7 - 12
  • [38] Risk of Fracture at External Fixator Pin Hole After Lateral Tibial Plateau Fracture Plating: A Biomechanical Comparison of Different Screw Configurations
    Massey, Patrick A.
    Scalisi, Wayne
    Duval, Chloe
    Lowery, Michael
    Chauvin, Brad
    Solitro, Giovanni F.
    JBJS OPEN ACCESS, 2025, 10 (01)
  • [39] Predictors of reduction loss in tibial plateau fracture surgery: Focusing on posterior coronal fractures
    Kim, Chang-Wan
    Lee, Chang-Rack
    An, Ki-Chan
    Gwak, Heui-Chul
    Kim, Jung-Han
    Wang, Lih
    Yoon, Dong-Gil
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (07): : 1483 - 1487
  • [40] Double-Incision Approach and Early Rehabilitation in a Complicated Bicondylar Tibial Plateau Fracture: A Case Report
    Affatato, Saverio
    Montalti, Maurizio
    Masetti, Claudio
    Giardina, Federico
    Sudanese, Alessandra
    MEDICAL PRINCIPLES AND PRACTICE, 2017, 26 (04) : 387 - 389