Biomechanical Comparison of 2 Double Plating Methods in a Coronal Fracture Model of Bicondylar Tibial Plateau Fractures

被引:2
|
作者
Samsami, Shabnam [1 ]
Patzold, Robert [2 ,3 ]
Neuy, Tim [4 ]
Greinwald, Markus [2 ]
Muller, Peter E. [5 ]
Chevalier, Yan [5 ]
Puschel, Klaus [6 ]
Augat, Peter [2 ,7 ]
机构
[1] Imperial Coll London, Dept Mech Engn, South Kensington Campus, London SW7 2AZ, England
[2] Berufsgenossenschaftl Unfallklin, Dept Inst Biomech, Murnau, Germany
[3] Berufsgenossenschaftl Unfallklin, Dept Trauma Surg, Murnau, Germany
[4] Paracelsus Med Univ, Med Dept, Salzburg, Austria
[5] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Orthopaed Phys Med & Rehabil, Munich, Germany
[6] Univ Med Ctr Hamburg Eppendorf, Dept Forens Med, Hamburg, Germany
[7] Paracelsus Med Univ, Dept Inst Biomech, Salzburg, Austria
关键词
bicondylar tibial plateau fracture; posteromedial fracture fragment; coronal fracture model; double plating osteosynthesis; mechanical test; interfragmentary movement; LESS INVASIVE STABILIZATION; POSTEROMEDIAL FRAGMENT; INTERNAL-FIXATION; REDUCTION; CLASSIFICATION; MORPHOLOGY; LOCKING; SINGLE;
D O I
10.1097/BOT.0000000000002257
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: Because management of bicondylar tibial plateau fractures are complicated even for expert surgeons, with using a coronal fracture model, we aimed to compare 2 kinds of double locked plating techniques that consisted of the lateral locking plate and the medial locking plate inserted medial anteriorly (MA-ly) or medial posteriorly (MP-ly). Methods: Fourteen fresh-frozen tibias stabilized with the MA or MP methods were allocated into 2 groups with similar bone mineral density values. Implanted samples were tested under incremental fatigue loading conditions using a customized load applicator. An optical motion tracking system was used to assess relative displacements and rotations of fracture fragments during loading. Static and dynamic global stiffness, failure load, failure cycles, as well as movements of fracture fragments were measured. Results: There were no significant differences between the 2 fixation methods regarding global stiffness, failure load, or failure cycles (P = 0.67-0.98, depending on the parameter). The kinematic evaluations, however, revealed that different positions of the medial locking plates altered the directions of movements for the medial-anterior or medial-posterior fracture segments. Conclusions: The mechanical stability of tibia-implant constructs fixed with the double plating methods was not remarkably affected by the location of the medial locking plate. Depending on clinical conditions and surgeons' preferences, bicondylar tibial plateau fractures can be managed with either MA or MP methods.
引用
收藏
页码:E129 / E135
页数:7
相关论文
共 50 条
  • [21] Incidence and Fracture Morphology of Posterolateral Fragments in Lateral and Bicondylar Tibial Plateau Fractures
    Sohn, Hoon-Sang
    Yoon, Yong-Cheol
    Cho, Jae-Woo
    Cho, Won-Tae
    Oh, Chang-Wug
    Oh, Jong-Keon
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2015, 29 (02) : 91 - 97
  • [22] Bicondylar tibial plateau fracture treated by open reduction and fixation with unilateral locked plating
    Lee, Tien-Ching
    Huang, Hsuan-Ti
    Lin, Yu-Chuan
    Chen, Chung-Hwan
    Cheng, Yuh-Min
    Chen, Jian-Chih
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2013, 29 (10): : 568 - 577
  • [23] Dual plating or dual plating combined with compression bolts for bicondylar tibial plateau fractures: a retrospective comparative study
    Zhongzheng Wang
    Yuchuan Wang
    Siyu Tian
    Zhanchao Tan
    Xiangtian Deng
    Kuo Zhao
    Zhanle Zheng
    Wei Chen
    Zhiyong Hou
    Yingze Zhang
    Scientific Reports, 11
  • [24] Dual plating or dual plating combined with compression bolts for bicondylar tibial plateau fractures: a retrospective comparative study
    Wang, Zhongzheng
    Wang, Yuchuan
    Tian, Siyu
    Tan, Zhanchao
    Deng, Xiangtian
    Zhao, Kuo
    Zheng, Zhanle
    Chen, Wei
    Hou, Zhiyong
    Zhang, Yingze
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [25] Complications of High-Energy Bicondylar Tibial Plateau Fractures Treated With Dual Plating Through 2 Incisions
    Ruffolo, Michael R.
    Gettys, Franklin K.
    Montijo, Harvey E.
    Seymour, Rachel B.
    Karunakar, Madhav A.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2015, 29 (02) : 85 - 90
  • [26] Biomechanical aspects of the posteromedial split in bicondylar tibial plateau fractures—a finite-element investigation
    J. Dehoust
    M. Münch
    K. Seide
    T. Barth
    K.-H. Frosch
    European Journal of Trauma and Emergency Surgery, 2020, 46 : 1257 - 1266
  • [27] Bicondylar tibial plateau fractures managed with the Sheffield Hybrid Fixator - Biomechanical study and operative technique
    Ali, AM
    Yang, L
    Hashmi, M
    Saleh, M
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2001, 32 : D86 - D91
  • [28] Outcome Analysis of Dual Plating in Management of Unstable Bicondylar Tibial Plateau Fracture - A Prospective Study
    Raj, M.
    Gill, S. P. S.
    Rajput, A.
    Singh, K. S.
    Verma, K. S.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2021, 15 (03) : 29 - 35
  • [29] Fracture pattern and fixation type related to loss of reduction in bicondylar tibial plateau fractures
    Weaver, Michael J.
    Harris, Mitchel B.
    Strom, Adam C.
    Smith, R. Malcolm
    Lhowe, David
    Zurakowski, David
    Vrahas, Mark S.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (06): : 864 - 869
  • [30] Tibial Plateau Fracture Characteristics: Computed Tomography Mapping of Lateral, Medial, and Bicondylar Fractures
    Molenaars, Rik J.
    Mellema, Jos J.
    Doornberg, Job N.
    Kloen, Peter
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2015, 97A (18): : 1512 - 1520