Biomechanical Comparison of 2 Double Plating Methods in a Coronal Fracture Model of Bicondylar Tibial Plateau Fractures

被引:2
|
作者
Samsami, Shabnam [1 ]
Patzold, Robert [2 ,3 ]
Neuy, Tim [4 ]
Greinwald, Markus [2 ]
Muller, Peter E. [5 ]
Chevalier, Yan [5 ]
Puschel, Klaus [6 ]
Augat, Peter [2 ,7 ]
机构
[1] Imperial Coll London, Dept Mech Engn, South Kensington Campus, London SW7 2AZ, England
[2] Berufsgenossenschaftl Unfallklin, Dept Inst Biomech, Murnau, Germany
[3] Berufsgenossenschaftl Unfallklin, Dept Trauma Surg, Murnau, Germany
[4] Paracelsus Med Univ, Med Dept, Salzburg, Austria
[5] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Orthopaed Phys Med & Rehabil, Munich, Germany
[6] Univ Med Ctr Hamburg Eppendorf, Dept Forens Med, Hamburg, Germany
[7] Paracelsus Med Univ, Dept Inst Biomech, Salzburg, Austria
关键词
bicondylar tibial plateau fracture; posteromedial fracture fragment; coronal fracture model; double plating osteosynthesis; mechanical test; interfragmentary movement; LESS INVASIVE STABILIZATION; POSTEROMEDIAL FRAGMENT; INTERNAL-FIXATION; REDUCTION; CLASSIFICATION; MORPHOLOGY; LOCKING; SINGLE;
D O I
10.1097/BOT.0000000000002257
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: Because management of bicondylar tibial plateau fractures are complicated even for expert surgeons, with using a coronal fracture model, we aimed to compare 2 kinds of double locked plating techniques that consisted of the lateral locking plate and the medial locking plate inserted medial anteriorly (MA-ly) or medial posteriorly (MP-ly). Methods: Fourteen fresh-frozen tibias stabilized with the MA or MP methods were allocated into 2 groups with similar bone mineral density values. Implanted samples were tested under incremental fatigue loading conditions using a customized load applicator. An optical motion tracking system was used to assess relative displacements and rotations of fracture fragments during loading. Static and dynamic global stiffness, failure load, failure cycles, as well as movements of fracture fragments were measured. Results: There were no significant differences between the 2 fixation methods regarding global stiffness, failure load, or failure cycles (P = 0.67-0.98, depending on the parameter). The kinematic evaluations, however, revealed that different positions of the medial locking plates altered the directions of movements for the medial-anterior or medial-posterior fracture segments. Conclusions: The mechanical stability of tibia-implant constructs fixed with the double plating methods was not remarkably affected by the location of the medial locking plate. Depending on clinical conditions and surgeons' preferences, bicondylar tibial plateau fractures can be managed with either MA or MP methods.
引用
收藏
页码:E129 / E135
页数:7
相关论文
共 50 条
  • [1] Lateral Locked Plating or Dual Plating: A Comparison of Two Methods in Simple Bicondylar Tibial Plateau Fractures
    Citak, Caner
    Kayali, Cemil
    Ozan, Firat
    Altay, Taskin
    Karahan, Huseyin Gokhan
    Yamak, Kamil
    CLINICS IN ORTHOPEDIC SURGERY, 2019, 11 (02) : 151 - 158
  • [2] Bicondylar tibial plateau fractures: A biomechanical study
    Mueller, KL
    Karunakar, MA
    Frankenburg, EP
    Scott, DS
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (412) : 189 - 195
  • [3] Dual locked plating of unstable bicondylar tibial plateau fractures
    Ozkaya, Ufuk
    Parmaksizoglu, Atilla Sancar
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 : S9 - S13
  • [4] Triple plating of tibia in a complex bicondylar tibial plateau fracture
    Atin Jaiswal
    Naiman Deepak Kachchhap
    Yashwant S Tanwar
    Birendra Kumar
    Sachin K Yadav
    中华创伤杂志(英文版), 2014, 17 (03) : 183 - 186
  • [5] Triple plating of tibia in a complex bicondylar tibial plateau fracture
    Jaiswal, Atin
    Kachchhap, Naiman Deepak
    Tanwar, Yashwant S.
    Kumar, Birendra
    Yadav, Sachin K.
    CHINESE JOURNAL OF TRAUMATOLOGY, 2014, 17 (03) : 183 - 186
  • [6] The Comparative Analysis of Single Plating Versus Double Plating in the Treatment of Unstable Bicondylar Proximal Tibial Plateau Fractures
    Raj, Manish
    Singh, Santosh Kumar
    Rajput, Ajay K.
    Gill, Simrat Pal
    Verma, Satyendra K.
    Sonarkar, Sushant S.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (10)
  • [7] COMPARISON OF BICONDYLAR TIBIAL PLATEAU FRACTURES WITH DOUBLE OR SINGLE LATERAL LOCKED PLATE
    Arouca, Matheus Manolo
    Ricardo da Costa, Guilherme Henrique
    Leonhardt, Marcos Camargo
    Barbosa, Dennis
    Silva, Jorge dos Santos
    Kojima, Kodi Edson
    ACTA ORTOPEDICA BRASILEIRA, 2020, 28 (04): : 182 - 185
  • [8] Single lateral locked screw plating of bicondylar tibial plateau fractures
    Gosling, T
    Schandelmaier, P
    Muller, M
    Hankemeier, S
    Wagner, M
    Krettek, C
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (439) : 207 - 214
  • [9] Supine Posterior Hoop Plating of Bicondylar Posterior Coronal Shear Tibial Plateau Fractures Without Fibular Osteotomy
    Foos, Julia K.
    Josifi, Erlena
    Large, Thomas M.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2023, 37 (01) : E45 - E50
  • [10] Comparison of outcome of unilateral locking plate and dual plating in the treatment of bicondylar tibial plateau fractures
    Lee, Meng-Hsuan
    Hsu, Chien-Jen
    Lin, Kai-Cheng
    Renn, Jenn-Huei
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2014, 9