DYNAMIC JAWS AND DYNAMIC COUCH IN HELICAL TOMOTHERAPY

被引:60
|
作者
Sterzing, Florian [1 ]
Uhl, Matthias [1 ]
Hauswald, Henrik [1 ]
Schubert, Kai [1 ]
Sroka-Perez, Gabriele [1 ]
Chen, Yu [2 ]
Lu, Weiguo [2 ]
Mackie, Rock [2 ]
Debus, Juergen [1 ]
Herfarth, Klaus [1 ]
Oliveira, Gustavo [2 ]
机构
[1] Univ Heidelberg, Dept Radiat Oncol, D-69120 Heidelberg, Germany
[2] Tomotherapy Inc, Madison, WI USA
关键词
Helical tomotherapy; Dynamic jaws; Dynamic couch; Longitudinal dose profile; Nasopharyngeal cancer; MODULATED RADIATION-THERAPY; NASOPHARYNX CANCER; CONFORMAL RADIOTHERAPY; NECK-CANCER; IMRT; HEAD; DELINEATION; IRRADIATION; EXPERIENCE; DELIVERY;
D O I
10.1016/j.ijrobp.2009.07.1686
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate the next generation of helical tomotherapy delivery with dynamic jaw and dynamic couch movements. Methods and Materials: The new technique of dynamic jaw and dynamic couch movements is described, and a comparative planning study is performed. Ten nasopharyngeal cancer patients with skull base infiltration were chosen for this comparison of longitudinal dose profiles using regular tomotherapy delivery, running-start-stop treatment, and dynamic jaw and dynamic couch delivery. A multifocal simultaneous integrated boost concept was used (70.4Gy to the primary tumor and involved lymph nodes; 57.4Gy to the bilateral cervical lymphatic drainage pathways, 32 fractions). Target coverage, conformity, homogeneity, sparing of organs at risk, integral dose, and radiation delivery time were evaluated. Results: Mean parotid dose for all different deliveries was between 24.8 and 26.1Gy, without significant differences. The mean integral dose was lowered by 6.3% by using the dynamic technique, in comparison with a 2.5-cm-field width for regular delivery and 16.7% with 5-cm-field width for regular delivery. Dynamic jaw and couch movements reduced the calculated radiation time by 66% of the time required with regular 2.5-cm-field width delivery (199 sec vs. 595 sec, p<0.001). Conclusions: The current delivery mode of helical tomotherapy produces dose distributions with conformal avoidance of parotid glands, brain stem, and spinal cord. The new technology with dynamic jaw and couch movements improves the plan quality by reducing the dose penumbra and thereby reducing the integral dose. In addition, radiation time is reduced by 66% of the regular delivery time. (C) 2010 Elsevier Inc.
引用
收藏
页码:1266 / 1273
页数:8
相关论文
共 50 条
  • [41] Lung and liver SBRT using helical tomotherapy - a dosimetric comparison of fixed jaw and dynamic jaw delivery
    Rudofsky, Leonie
    Aynsley, Eleanor
    Beck, Sebastian
    Schubert, Kai
    Habl, Gregor
    Krause, Sonja
    Debus, Juergen
    Sterzing, Florian
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (03): : 114 - 121
  • [42] INSTRUMENTATION OF A MOBILIZATION COUCH FOR DYNAMIC LOAD MEASUREMENT
    HARMS, MC
    MILTON, AM
    CUSICK, G
    BADER, DL
    JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1995, 19 (04) : 119 - 122
  • [43] Instrumentation of a mobilization couch for dynamic load measurement
    Physiotherapy Department, NHS Trust, Middlesex Hospital, Mortimer Street, London W1N 8AA, United Kingdom
    J. MED. ENG. TECHNOL., 4 (119-122):
  • [44] Clinical Implementation of Real-time Motion Tracking With Jaws and MLC during Helical Tomotherapy Delivery
    Chen, G. P.
    Tai, A.
    Puckett, L.
    Lim, S. N.
    Keiper, T.
    Gore, E. M.
    Johnstone, C.
    Lawton, C. A. F.
    Li, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E257 - E258
  • [45] Helical tomotherapy experience
    Ramsey, C.
    MEDICAL PHYSICS, 2007, 34 (06) : 2604 - 2604
  • [46] Comparing step-and-shoot IMRT with dynamic helical tomotherapy IMRT plans for head-and-neck cancer
    Van Vulpen, M
    Field, C
    Raaijmakers, CPJ
    Parliament, MB
    Terhaard, CHJ
    MacKenzie, MA
    Scrimger, R
    Lagendijk, JJW
    Fallone, BG
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (05): : 1535 - 1539
  • [47] Couch modeling optimization for tomotherapy planning and delivery
    Okada, Wataru
    Tanooka, Masao
    Sano, Keisuke
    Shibata, Mayuri
    Doi, Hiroshi
    Miyazaki, Masayoshi
    Nakahara, Ryuta
    Sueoka, Masaki
    Suzuki, Hitomi
    Fujiwara, Masayuki
    Inomata, Taisuke
    Yamakado, Koichiro
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (08): : 114 - 121
  • [48] Couch modeling optimization for TomoTherapy planning and delivery
    Tanooka, M.
    Okada, W.
    Sano, K.
    Mayuri, S.
    Doi, H.
    Miyazaki, M.
    Nakahara, R.
    Sueoka, M.
    Suzuki, H.
    Fujiwara, M.
    Kamikonya, N.
    Inomata, Y.
    Yamakado, K.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S999 - S999
  • [49] Dynamic Delivery of IMRT Using Independent Jaws
    Zhang, Y.
    Dai, J.
    Ma, L.
    Hu, Y.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [50] DYNAMIC STRESS IN HELICAL SPRINGS
    KURAN, AA
    MACHINE DESIGN, 1972, 44 (27) : 131 - &