Evaluation of RF Noise Shielding Effectiveness for the Improvement of MR Image in Hybrid PET/MRI

被引:0
|
作者
Lim, Hyun Keong [1 ]
Choi, Yong [1 ]
Jung, Jin Ho [1 ]
Jung, Jiwoong [1 ]
Oh, Chang Hyun [2 ]
Kim, Kyung Min [3 ]
Kim, Jong Guk [3 ]
Park, Hyun-wook [2 ]
机构
[1] Sogang Univ, Dept Elect Engn, Mol Imaging Res & Educ MiRe Lab, Seoul, South Korea
[2] Korea Adv Inst Sci & Technol, Dept Elect Engn, Taejon, South Korea
[3] Korea Inst Radiol & Med Sci, Seoul, South Korea
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The hybrid PET and MRI which could provide information on functional and structural images was required to improve the mutual compatibility. The purpose of this study is to propose a new electromagnetic shielding material; Au plated conductive fabric (Au PCF) tape, and evaluated shielding effectiveness of Au PCF tape and Cu foil for insertable PET in hybrid PET/A/IRE The PET consisted of 18 detector blocks arranged in a ring of 390 mm diameter and 60 mm axial FOV. Each detector block was constituted of 4 x 4 matrix of detector module, each of which consisted of a 4 x 4 array LSO coupled to a 4 x 4 GAPD array. The PET gantry was positioned in center of two 3T Human MRIs and shielded with Au PCF tape or Cu foil. The PET readout electronics were enclosed in an aluminum shielding box behind MRI. RF head coil was also shielded with Au PCF tape or Cu foil to improve shielding effects. The MR image of cylindrical water phantom was acquired to evaluate MR image homogeneity and signal-to-noise ratio (SNR) with various MR sequences. The homogeneity of MR Images was similar without and with PET gantry shielded with Au PCF tape and Cu foil. SNRs measured without and with PET gantry shielded with Au PCF tape have small differences (<4%). SNR was decreased <similar to 9% with PET gantry shielded with Cu foil. Experimental results indicate that Au PCF tape have good performance of electromagnetic shielding to reduce the effect of RF noise on the MR image in hybrid PET-MR.
引用
收藏
页数:3
相关论文
共 50 条
  • [31] Adequate evaluation of image registration in hybrid PET/CT
    Vogel, Wouter V.
    van Dalen, Jorn A.
    Oyen, Wirn J. G.
    JOURNAL OF NUCLEAR MEDICINE, 2006, 47 (09) : 1556 - 1556
  • [32] Evaluation of cortical uptake of amyloid PET tracer with hybrid PET/MRI; comparison with PET/CT
    Baba, Shingo
    Isoda, Takuro
    Maruoka, Yasuhiro
    Kitamura, Yoshiyuki
    Sagiyama, Koji
    Kamei, Ryotaro
    Watanabe, Yuji
    Honda, Hiroshi
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [33] Complementary usefulness of PET and MRI in evaluation of gliomas: Preliminary study for feasibility of integrated PET/MR
    Chun, In Kook
    Paeng, Jin Chul
    Kim, Yong-il
    Kang, Keon
    Chung, June-Key
    Lee, Myung Chul
    Lee, Dong Soo
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [34] Mutual Information Metric Evaluation for PET/MRI Image Fusion
    Gupta, Shruti
    Ramesh, Karthik P.
    Blasch, Erik P.
    NAECON 2008 - IEEE NATIONAL AEROSPACE AND ELECTRONICS CONFERENCE, 2008, : 305 - +
  • [35] An evaluation of image noise variance for time-of-flight PET
    Watson, Charles C.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (05) : 1639 - 1647
  • [36] An evaluation of image noise variance for time-of-flight PET
    Watson, Charles C.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2041 - 2045
  • [37] Shielding Effectiveness Improvement Method of Optoelectronic Instrumental Windows Utilizing Transparent Mesh PET Film
    Kai, Cao
    Wang, Kairang
    Liu, Changwen
    WIRELESS AND SATELLITE SYSTEMS, PT II, 2019, 281 : 656 - 660
  • [38] Design, Implementation, and Evaluation of a Head and Neck MRI RF Array Integrated with a 511 keV Transmission Source for Attenuation Correction in PET/MR
    de lara, Lucia Isabel Navarro
    Frass-Kriegl, Roberta
    Renner, Andreas
    Sieg, Juergen
    Pichler, Michael
    Bogner, Thomas
    Moser, Ewald
    Beyer, Thomas
    Birkfellner, Wolfgang
    Figl, Michael
    Laistler, Elmar
    SENSORS, 2019, 19 (15)
  • [39] PET Image Quality Improvement for Simultaneous PET/MRI with a Lightweight MRI Surface Coil (vol 298, pg 166, 2021)
    Deller, Timothy W.
    Mathew, Nicholas K.
    Hurley, Samuel A.
    Bobb, Chad M.
    McMillan, Alan B.
    RADIOLOGY, 2021, 298 (03)
  • [40] Systematic Evaluation of Phantom Fluids for Simultaneous PET/MR Hybrid Imaging
    Ziegler, Susanne
    Braun, Harald
    Ritt, Philipp
    Hocke, Carsten
    Kuwert, Torsten
    Quick, Harald H.
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (08) : 1464 - 1471