Evaluation of RF Noise Shielding Effectiveness for the Improvement of MR Image in Hybrid PET/MRI

被引:0
|
作者
Lim, Hyun Keong [1 ]
Choi, Yong [1 ]
Jung, Jin Ho [1 ]
Jung, Jiwoong [1 ]
Oh, Chang Hyun [2 ]
Kim, Kyung Min [3 ]
Kim, Jong Guk [3 ]
Park, Hyun-wook [2 ]
机构
[1] Sogang Univ, Dept Elect Engn, Mol Imaging Res & Educ MiRe Lab, Seoul, South Korea
[2] Korea Adv Inst Sci & Technol, Dept Elect Engn, Taejon, South Korea
[3] Korea Inst Radiol & Med Sci, Seoul, South Korea
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The hybrid PET and MRI which could provide information on functional and structural images was required to improve the mutual compatibility. The purpose of this study is to propose a new electromagnetic shielding material; Au plated conductive fabric (Au PCF) tape, and evaluated shielding effectiveness of Au PCF tape and Cu foil for insertable PET in hybrid PET/A/IRE The PET consisted of 18 detector blocks arranged in a ring of 390 mm diameter and 60 mm axial FOV. Each detector block was constituted of 4 x 4 matrix of detector module, each of which consisted of a 4 x 4 array LSO coupled to a 4 x 4 GAPD array. The PET gantry was positioned in center of two 3T Human MRIs and shielded with Au PCF tape or Cu foil. The PET readout electronics were enclosed in an aluminum shielding box behind MRI. RF head coil was also shielded with Au PCF tape or Cu foil to improve shielding effects. The MR image of cylindrical water phantom was acquired to evaluate MR image homogeneity and signal-to-noise ratio (SNR) with various MR sequences. The homogeneity of MR Images was similar without and with PET gantry shielded with Au PCF tape and Cu foil. SNRs measured without and with PET gantry shielded with Au PCF tape have small differences (<4%). SNR was decreased <similar to 9% with PET gantry shielded with Cu foil. Experimental results indicate that Au PCF tape have good performance of electromagnetic shielding to reduce the effect of RF noise on the MR image in hybrid PET-MR.
引用
收藏
页数:3
相关论文
共 50 条
  • [11] Noise contamination from PET blood sampling pump: Effects on structural MRI image quality in simultaneous PET/MR studies
    Bartlett, Elizabeth
    DeLorenzo, Christine
    Parsey, Ramin
    Huang, Chuan
    MEDICAL PHYSICS, 2018, 45 (02) : 678 - 686
  • [12] Evaluation of image noise in respiratory gated PET
    Detorie, Nicole C.
    Kesner, Adam L.
    Solberg, Timothy D.
    Dahlbom, Magnus
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (01) : 66 - 70
  • [13] Performance evaluation of RF coils integrated with an RF-penetrable PET insert for simultaneous PET/MRI
    Lee, Brian J.
    Watkins, Ronald D.
    Lee, Keum Sil
    Chang, Chen-Ming
    Levin, Craig S.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (02) : 1434 - 1446
  • [14] PET Performance Evaluation of a RF-Penetrable PET Insert for Simultaneous PET/MR Imaging
    Chang, Chen-Ming
    Grant, Alexander M.
    Lee, Brian J.
    Levin, Craig S.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [15] Evaluation of PET Image Quality and Distortions in Simultaneous Clinical PET/MR
    Keller, Sune H.
    Hansen, Adam E.
    Beyer, Thomas
    Andersen, Flemming L.
    Klausen, Thomas L.
    Lofgren, Lohan
    Holm, Soren
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2766 - 2768
  • [16] Comparison of Tumor Volume Between PET and MRI in Cervical Cancer With Hybrid PET/MR
    Zhang, Shaomin
    Xin, Jun
    Guo, Qiyong
    Ma, Jietao
    Ma, Quanmei
    Sun, Hongzan
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2014, 24 (04) : 744 - 750
  • [17] Brain PET and functional MRI: why simultaneously using hybrid PET/MR systems?
    Cechin, Diego
    Palombit, Alessandro
    Castelaro, Marco
    Silvestri, Erica
    Bui, Franco
    Barthel, Henryk
    Sabri, Osama
    Corbetta, Maurizio
    Bertoldo, Alessandra
    QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 61 (04): : 345 - 359
  • [18] Approaches for the optimization of MR protocols in clinical hybrid PET/MRI studies
    Vargas, Maria-Isabel
    Becker, Minerva
    Garibotto, Valentina
    Heinzer, Susanne
    Loubeyre, Pierre
    Gariani, Joanna
    Lovblad, Karl
    Vallee, Jean-Paul
    Ratib, Osman
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2013, 26 (01) : 57 - 69
  • [19] Approaches for the optimization of MR protocols in clinical hybrid PET/MRI studies
    Maria-Isabel Vargas
    Minerva Becker
    Valentina Garibotto
    Susanne Heinzer
    Pierre Loubeyre
    Joanna Gariani
    Karl Lovblad
    Jean-Paul Vallée
    Osman Ratib
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2013, 26 : 57 - 69
  • [20] Quantitative evaluation on truncated attenuation image in PET/MRI
    Moon, Ill Sang
    Lee, Jae Sung
    Lee, Dong Soo
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55