Computerized analysis of brain perfusion parameter images

被引:20
|
作者
Turowski, B. [1 ]
Haenggi, D. [1 ]
Wittsack, H.-J. [1 ]
Beck, A. [1 ]
Aurich, V. [1 ]
机构
[1] Univ Klinikum Dusseldorf, Inst Informat, D-40225 Dusseldorf, Germany
关键词
hemorrhage; brain; CT;
D O I
10.1055/s-2007-962853
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The development of a computerized method which allows a direct quantitative comparison of perfusion parameters. The display should allow a clear direct comparison of brain perfusion parameters in different vascular territories and over the course of time. The analysis is intended to be the basis for further evaluation of cerebral vasospasm after subarachnoid hemorrhage (SAH). The method should permit early diagnosis of cerebral vasospasm. Materials and Methods: The Angiotux 2D-ECCET software was developed with a close cooperation between computer scientists and clinicians. Starting from parameter images of brain perfusion, the cortex was marked, segmented and assigned to definite vascular territories. The underlying values were averages for each segment and were displayed in a graph. If a follow-up was available, the mean values of the perfusion parameters were displayed in relation to time. The method was developed under consideration of CT perfusion values but is applicable for other methods of perfusion imaging. Results: Computerized analysis of brain perfusion parameter images allows an immediate comparison of these parameters and follow-up of mean values in a clear and concise manner. Values are related to definite vascular territories. The tabular output facilitates further statistic evaluations. The computerized analysis is precisely reproducible, i.e., repetitions result in exactly the same output. Conclusion: Computerized analysis of brain perfusion parameters with Angiotux 2D-ECCET is objective and ensures reproducible results. It may become the basis and a requirement for the analysis of minimal changes in brain perfusion prior to irreversible damage from posthemorrhagic vasospasm.
引用
收藏
页码:525 / 529
页数:5
相关论文
共 50 条
  • [1] METHOD FOR COMPUTERIZED INTERPRETATION OF MYOCARDIAL PERFUSION SCINTIGRAPHIC IMAGES
    LEFREE, MT
    VOGEL, RA
    KIRCH, DL
    STEELE, PP
    JOURNAL OF NUCLEAR MEDICINE, 1978, 19 (06) : 748 - 748
  • [2] COMPUTERIZED ANALYSIS OF GUINIER IMAGES
    DINNEBIER, R
    EYSEL, W
    FORTSCHRITTE DER MINERALOGIE, 1988, 66 : 28 - 28
  • [3] Computerized analysis of chest CT images
    Toriwaki, J
    Shimizu, A
    Mori, K
    COMPUTER-AIDED DIAGNOSIS IN MEDICAL IMAGING, 1999, 1182 : 35 - 44
  • [4] Future of computerized analysis of vascular images
    Reiber, JHC
    Goedhart, B
    Dijkstra, J
    Koning, G
    Oemrawsingh, PV
    Jukema, JW
    van der Geest, RJ
    COMPUTER-AIDED DIAGNOSIS IN MEDICAL IMAGING, 1999, 1182 : 319 - 331
  • [5] Computerized analysis of magnetic resonance images
    SoltanianZadeh, H
    Windham, JP
    SCIA '97 - PROCEEDINGS OF THE 10TH SCANDINAVIAN CONFERENCE ON IMAGE ANALYSIS, VOLS 1 AND 2, 1997, : 133 - 139
  • [6] Matching a computerized brain atlas to multimodal medical images
    Rizzo, G
    Scifo, P
    Gilardi, MC
    Bettinardi, V
    Grassi, F
    Cerutti, S
    Fazio, F
    NEUROIMAGE, 1997, 6 (01) : 59 - 69
  • [7] Symmetry plane of the brain on perfusion MR images
    Kartaszyński R.H.
    Mikołajczak P.
    Advances in Intelligent and Soft Computing, 2010, 69 : 65 - 72
  • [8] Human brain anatomy in computerized images - Damasio,H
    Grahovac, SZ
    JOURNAL OF PSYCHIATRY & NEUROSCIENCE, 1997, 22 (02): : 138 - 138
  • [9] Multi-Parameter Segmentation of Brain Images
    Dhawan, Atam P.
    D'Alessandro, Brian
    2009 4TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING, 2009, : 215 - +
  • [10] Semiautomated analysis of the extent and severity of perfusion defects on brain SPECT images: validation studies
    Baird, AE
    Austin, MC
    O'Keefe, GJ
    McKay, WJ
    Donnan, GA
    JOURNAL OF CLINICAL NEUROSCIENCE, 1999, 6 (02) : 121 - 127