Computerized analysis of brain perfusion parameter images

被引:20
|
作者
Turowski, B. [1 ]
Haenggi, D. [1 ]
Wittsack, H.-J. [1 ]
Beck, A. [1 ]
Aurich, V. [1 ]
机构
[1] Univ Klinikum Dusseldorf, Inst Informat, D-40225 Dusseldorf, Germany
关键词
hemorrhage; brain; CT;
D O I
10.1055/s-2007-962853
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The development of a computerized method which allows a direct quantitative comparison of perfusion parameters. The display should allow a clear direct comparison of brain perfusion parameters in different vascular territories and over the course of time. The analysis is intended to be the basis for further evaluation of cerebral vasospasm after subarachnoid hemorrhage (SAH). The method should permit early diagnosis of cerebral vasospasm. Materials and Methods: The Angiotux 2D-ECCET software was developed with a close cooperation between computer scientists and clinicians. Starting from parameter images of brain perfusion, the cortex was marked, segmented and assigned to definite vascular territories. The underlying values were averages for each segment and were displayed in a graph. If a follow-up was available, the mean values of the perfusion parameters were displayed in relation to time. The method was developed under consideration of CT perfusion values but is applicable for other methods of perfusion imaging. Results: Computerized analysis of brain perfusion parameter images allows an immediate comparison of these parameters and follow-up of mean values in a clear and concise manner. Values are related to definite vascular territories. The tabular output facilitates further statistic evaluations. The computerized analysis is precisely reproducible, i.e., repetitions result in exactly the same output. Conclusion: Computerized analysis of brain perfusion parameters with Angiotux 2D-ECCET is objective and ensures reproducible results. It may become the basis and a requirement for the analysis of minimal changes in brain perfusion prior to irreversible damage from posthemorrhagic vasospasm.
引用
收藏
页码:525 / 529
页数:5
相关论文
共 50 条
  • [41] Computerized Analysis of Brain MRI Parameter Dynamics in Young Patients With Cushing Syndrome-A Case-Control Study
    Tirosh, Amit
    RaviPrakash, Harish
    Papadakis, Georgios Z.
    Tatsi, Christina
    Belyavskaya, Elena
    Charalampos, Lyssikatos
    Lodish, Maya B.
    Bagci, Ulas
    Stratakis, Constantine A.
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2020, 105 (05):
  • [42] Supervised diffusion parameter selection for processing SPECT brain images
    Beekman, FJ
    Slijpen, ETP
    Niessen, WJ
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 921 - 921
  • [43] Supervised diffusion parameter selection for filtering SPECT brain images
    Beekman, FJ
    Slijpen, ETP
    Niessen, WJ
    SCALE-SPACE THEORY IN COMPUTER VISION, 1997, 1252 : 164 - 175
  • [44] Automatic registration of 3D MR images with a computerized brain atlas
    Cuisenaire, O
    Thiran, JP
    Macq, B
    Michel, C
    DeVolder, A
    Marques, F
    MEDICAL IMAGING 1996: IMAGE PROCESSING, 1996, 2710 : 438 - 448
  • [45] Attenuation correction using deep learning for brain perfusion SPECT images
    Sakaguchi, Kenta
    Kaida, Hayato
    Yoshida, Shuhei
    Ishii, Kazunari
    ANNALS OF NUCLEAR MEDICINE, 2021, 35 (05) : 589 - 599
  • [46] Progressive Knowledge Distillation for Automatic Perfusion Parameter Maps Generation from Low Temporal Resolution CT Perfusion Images
    Son, Moo Hyun
    Bae, Juyoung
    Tong, Elizabeth
    Chen, Hao
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2024, PT X, 2024, 15010 : 611 - 621
  • [47] Attenuation correction using deep learning for brain perfusion SPECT images
    Kenta Sakaguchi
    Hayato Kaida
    Shuhei Yoshida
    Kazunari Ishii
    Annals of Nuclear Medicine, 2021, 35 : 589 - 599
  • [48] Impact of CT attenuation correction by SPECT/CT in brain perfusion images
    Kazunari Ishii
    Kohei Hanaoka
    Masahiro Okada
    Seishi Kumano
    Yoshihiro Komeya
    Norio Tsuchiya
    Makoto Hosono
    Takamichi Murakami
    Annals of Nuclear Medicine, 2012, 26 : 241 - 247
  • [49] Impact of CT attenuation correction by SPECT/CT in brain perfusion images
    Ishii, Kazunari
    Hanaoka, Kohei
    Okada, Masahiro
    Kumano, Seishi
    Komeya, Yoshihiro
    Tsuchiya, Norio
    Hosono, Makoto
    Murakami, Takamichi
    ANNALS OF NUCLEAR MEDICINE, 2012, 26 (03) : 241 - 247
  • [50] Correlation of CT Perfusion Images with VEGF Expression in Solitary Brain Metastases
    Zhang, Jian-Hua
    Wang, Ming-Sheng
    Pan, Hai-Hong
    Li, Shu-Feng
    Wang, Zhong-Qiu
    Chen, Wang-Sheng
    ASIAN PACIFIC JOURNAL OF CANCER PREVENTION, 2012, 13 (04) : 1575 - 1578