Comparison of 3D double inversion recovery and 2D STIR FLAIR MR sequences for the imaging of optic neuritis: pilot study

被引:42
|
作者
Hodel, Jerome [1 ]
Outteryck, Olivier [2 ]
Bocher, Anne-Laure [1 ]
Zephir, Helene [2 ]
Lambert, Oriane [3 ]
Benadjaoud, Mohamed Amine [4 ]
Chechin, David [5 ]
Pruvo, Jean-Pierre [1 ]
Vermersch, Patrick [2 ]
Leclerc, Xavier [1 ]
机构
[1] Hop Roger Salengro, Dept Neuroradiol, F-59037 Lille, France
[2] Hop Roger Salengro, Dept Neurol, F-59037 Lille, France
[3] Fdn Ophtalmol Rothschild, Dept Neuroradiol, Paris, France
[4] INSERM, CESP Ctr Res Epidemiol & Populat Hlth, U1018, Radiat Epidemiol Team, Villejuif, France
[5] Philips Med Syst, Suresnes, France
关键词
Multiple sclerosis; Neuromyelitis optica; Clinically isolated syndrome; Optic neuritis; Double inversion recovery MR sequence; MULTIPLE-SCLEROSIS; INTRACORTICAL LESIONS; 7; TESLA; NERVE; CSF; SPECIFICITY; SENSITIVITY; ARTIFACTS; 3D-FLAIR; CONTRAST;
D O I
10.1007/s00330-014-3342-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We compared the three-dimensional (3D) double inversion recovery (DIR) magnetic resonance imaging (MRI) sequence with the coronal two-dimensional (2D) short tau inversion recovery (STIR) fluid-attenuated inversion recovery (FLAIR) for the detection of optic nerve signal abnormality in patients with optic neuritis (ON). The study group consisted of 31 patients with ON (44 pathological nerves) confirmed by visual-evoked potentials used as the reference. MRI examinations included 2D coronal STIR FLAIR and 3D DIR with 3-mm coronal reformats to match with STIR FLAIR. Image artefacts were graded for each portion of the optic nerves. Each set of MR images (2D STIR FLAIR, DIR reformats and multiplanar 3D DIR) was examined independently and separately for the detection of signal abnormality. Cisternal portion of optic nerves was better delineated with DIR (p < 0.001), while artefacts impaired analysis in four patients with STIR FLAIR. Inter-observer agreement was significantly improved (p < 0.001) on 3D DIR (kappa = 0.96) compared with STIR FLAIR images (kappa = 0.60). Multiplanar DIR images reached the best performance for the diagnosis of ON (95 % sensitive and 94 % specific). Our study showed a high sensitivity and specificity of 3D DIR compared with STIR FLAIR for the detection of ON. These findings suggest that the 3D DIR sequence may be more useful in patients suspected of ON. aEuro cent 3D DIR is increasingly used in neuroradiology aEuro cent Compared with STIR FLAIR, 3D DIR improves detection of optic neuritis aEuro cent Multiplanar analysis had the best diagnostic performance for optic nerve signal abnormalities aEuro cent Sensitivity was 95 % and specificity 94 % aEuro cent Findings support the use of 3D DIR instead of 2D sequences.
引用
收藏
页码:3069 / 3075
页数:7
相关论文
共 50 条
  • [31] Comparing 2D and 3D Imaging
    Ballantyne, Lauren
    JOURNAL OF VISUAL COMMUNICATION IN MEDICINE, 2011, 34 (03) : 138 - 141
  • [32] Detection of lesions in multiple sclerosis by 2D FLAIR and single-slab 3D FLAIR sequences at 3.0 T: initial results
    Bink, A
    Schmitt, M
    Gaa, J
    Mugler, JP
    Lanfermann, H
    Zanella, FE
    EUROPEAN RADIOLOGY, 2006, 16 (05) : 1104 - 1110
  • [33] Multiple sclerosis lesion detection with 3D double inversion recovery (DIR) as compared to 3D fluid low attenuation inversion recovery (T2-FLAIR): A systematic review and meta-analysis
    Mostardeiro, Thomaz R.
    Schmitt, Luiza Giuliani
    de Campos, Fillipe Thiago Xavier
    Xi, Yin
    Torri, Giovanni Brondani
    Carvalho, Bruno Murad
    Feltrin, Fabricio Stewan
    MULTIPLE SCLEROSIS AND RELATED DISORDERS, 2025, 93
  • [34] Detection of lesions in multiple sclerosis by 2D FLAIR and single-slab 3D FLAIR sequences at 3.0 T: initial results
    Andrea Bink
    Melanie Schmitt
    Jochen Gaa
    John P. Mugler
    Heinrich Lanfermann
    Friedhelm E. Zanella
    European Radiology, 2006, 16 : 1104 - 1110
  • [35] Population-based prevalence of infarctions on 3D fluid-attenuated inversion recovery (FLAIR) imaging
    Cogswell, Petrice M.
    Aakre, Jeremiah A.
    Castillo, Anna M.
    Knopman, David S.
    Kantarci, Kejal
    Rabinstein, Alejandro A.
    Petersen, Ronald C.
    Clifford, R. Jack, Jr.
    Mielke, Michelle M.
    Vemuri, Prashanthi
    Graff-Radford, Jonathan
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2022, 31 (08):
  • [36] Pulmonary MR angiography: A comparison of 2D and 3D time-of-flight
    Isoda, H., 1600, Lippincott Williams and Wilkins (18):
  • [37] Acute severe memory impairment as a presenting symptom of multiple sclerosis: a clinical case study with 3D double inversion recovery MR imaging
    Coebergh, J. A. F.
    Roosendaal, S. D.
    Polman, C. H.
    Geurts, J. J.
    van Woerkom, T. C. A. M.
    MULTIPLE SCLEROSIS, 2010, 16 (12): : 1521 - 1524
  • [38] Infarct quantification using 3D inversion recovery and 2D phase sensitive inversion recovery; validation in patients and ex vivo
    Jablonowski, Robert
    Nordlund, David
    Kanski, Mikael
    Ubachs, Joey
    Koul, Sasha
    Heiberg, Einar
    Engblom, Henrik
    Erlinge, David
    Arheden, Hakan
    Carlsson, Marcus
    BMC CARDIOVASCULAR DISORDERS, 2013, 13
  • [39] Infarct quantification using 3D inversion recovery and 2D phase sensitive inversion recovery, validation in patients and ex vivo
    Robert Jablonowski
    David Nordlund
    Henrik Engblom
    Joey F Ubachs
    Mikael Kanski
    Hakan Arheden
    Marcus Carlsson
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [40] Infarct quantification using 3D inversion recovery and 2D phase sensitive inversion recovery; validation in patients and ex vivo
    Robert Jablonowski
    David Nordlund
    Mikael Kanski
    Joey Ubachs
    Sasha Koul
    Einar Heiberg
    Henrik Engblom
    David Erlinge
    Håkan Arheden
    Marcus Carlsson
    BMC Cardiovascular Disorders, 13