Comparison of 3D double inversion recovery and 2D STIR FLAIR MR sequences for the imaging of optic neuritis: pilot study

被引:42
|
作者
Hodel, Jerome [1 ]
Outteryck, Olivier [2 ]
Bocher, Anne-Laure [1 ]
Zephir, Helene [2 ]
Lambert, Oriane [3 ]
Benadjaoud, Mohamed Amine [4 ]
Chechin, David [5 ]
Pruvo, Jean-Pierre [1 ]
Vermersch, Patrick [2 ]
Leclerc, Xavier [1 ]
机构
[1] Hop Roger Salengro, Dept Neuroradiol, F-59037 Lille, France
[2] Hop Roger Salengro, Dept Neurol, F-59037 Lille, France
[3] Fdn Ophtalmol Rothschild, Dept Neuroradiol, Paris, France
[4] INSERM, CESP Ctr Res Epidemiol & Populat Hlth, U1018, Radiat Epidemiol Team, Villejuif, France
[5] Philips Med Syst, Suresnes, France
关键词
Multiple sclerosis; Neuromyelitis optica; Clinically isolated syndrome; Optic neuritis; Double inversion recovery MR sequence; MULTIPLE-SCLEROSIS; INTRACORTICAL LESIONS; 7; TESLA; NERVE; CSF; SPECIFICITY; SENSITIVITY; ARTIFACTS; 3D-FLAIR; CONTRAST;
D O I
10.1007/s00330-014-3342-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We compared the three-dimensional (3D) double inversion recovery (DIR) magnetic resonance imaging (MRI) sequence with the coronal two-dimensional (2D) short tau inversion recovery (STIR) fluid-attenuated inversion recovery (FLAIR) for the detection of optic nerve signal abnormality in patients with optic neuritis (ON). The study group consisted of 31 patients with ON (44 pathological nerves) confirmed by visual-evoked potentials used as the reference. MRI examinations included 2D coronal STIR FLAIR and 3D DIR with 3-mm coronal reformats to match with STIR FLAIR. Image artefacts were graded for each portion of the optic nerves. Each set of MR images (2D STIR FLAIR, DIR reformats and multiplanar 3D DIR) was examined independently and separately for the detection of signal abnormality. Cisternal portion of optic nerves was better delineated with DIR (p < 0.001), while artefacts impaired analysis in four patients with STIR FLAIR. Inter-observer agreement was significantly improved (p < 0.001) on 3D DIR (kappa = 0.96) compared with STIR FLAIR images (kappa = 0.60). Multiplanar DIR images reached the best performance for the diagnosis of ON (95 % sensitive and 94 % specific). Our study showed a high sensitivity and specificity of 3D DIR compared with STIR FLAIR for the detection of ON. These findings suggest that the 3D DIR sequence may be more useful in patients suspected of ON. aEuro cent 3D DIR is increasingly used in neuroradiology aEuro cent Compared with STIR FLAIR, 3D DIR improves detection of optic neuritis aEuro cent Multiplanar analysis had the best diagnostic performance for optic nerve signal abnormalities aEuro cent Sensitivity was 95 % and specificity 94 % aEuro cent Findings support the use of 3D DIR instead of 2D sequences.
引用
收藏
页码:3069 / 3075
页数:7
相关论文
共 50 条
  • [21] 3D fluid attenuated inversion recovery (FLAIR) magnetic resonance imaging at different stages of otosclerosis
    Stefano Berrettini
    Francesco Lombardo
    Luca Bruschini
    Annalisa Ciabotti
    Canapicchi Raffaello
    Francesca De Cori Sara
    European Archives of Oto-Rhino-Laryngology, 2018, 275 : 2643 - 2652
  • [22] 3D fluid attenuated inversion recovery (FLAIR) magnetic resonance imaging at different stages of otosclerosis
    Berrettini, Stefano
    Lombardo, Francesco
    Bruschini, Luca
    Ciabotti, Annalisa
    Raffaello, Canapicchi
    Sara, De Cori
    Daniele, De Marchi
    Forli, Francesca
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2018, 275 (11) : 2643 - 2652
  • [23] Comparison of 2D and 3D MRI of the optic and oculomotor nerve anatomy
    Held, P
    Nitz, W
    Seitz, J
    Fründ, R
    Müller, HM
    Haffke, T
    Hees, H
    CLINICAL IMAGING, 2000, 24 (06) : 337 - 343
  • [24] Comparison between the diagnostic utility of three-dimensional fluid attenuated inversion recovery (3D FLAIR) and three dimensional double inversion recovery (3D DIR) magnetic resonance sequences in the assessment of overall load of multiple sclerosis lesions in the brain
    Saad, Nehal S.
    Gad, Azza A.
    Elzoghby, Mahmoud M.
    Ibrahim, Heba R.
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2024, 55 (01):
  • [25] Visualization of Endolymphatic Hydrops after Intratympanic Injection of Gd-DTPA: Comparison of 2D and 3D Real Inversion Recovery Imaging
    Naganawa, Shinji
    Sone, Michihiko
    Yamazaki, Masahiro
    Kawai, Hisashi
    Nakashima, Tsutomu
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2011, 10 (02) : 101 - 106
  • [26] Comparison of 2D and 3D myocardial PET imaging.
    Knesaurek, K
    Machac, J
    Krynyckyi, BR
    Almeida, OD
    Parisi, JC
    Kim, CK
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 46P - 46P
  • [27] Diagnostic value of contrast-enhanced 3D FLAIR sequence in acute optic neuritis
    Panyaping, Theeraphol
    Tunlayadechanont, Padcha
    Jindahra, Panitha
    Cheecharoen, Piyaphon
    NEURORADIOLOGY JOURNAL, 2023, 36 (06): : 674 - 679
  • [28] Comparison of flow artifacts between 2D-FLAIR and 3D-FLAIR sequences at 3 T
    Shinji Naganawa
    Tokiko Koshikawa
    Tatsuya Nakamura
    Hisashi Kawai
    Hiroshi Fukatsu
    Takeo Ishigaki
    Tomomi Komada
    Katsuya Maruyama
    Osamu Takizawa
    European Radiology, 2004, 14 : 1901 - 1908
  • [29] Comparison of flow artifacts between 2D-FLAIR and 3D-FLAIR sequences at 3 T
    Naganawa, S
    Koshikawa, T
    Nakamura, T
    Kawai, H
    Fukatsu, H
    Ishigaki, T
    Komada, T
    Maruyama, K
    Takizawa, O
    EUROPEAN RADIOLOGY, 2004, 14 (10) : 1901 - 1908
  • [30] Comparison of 3D Imaging and 2D Imaging for Performance Time of Laparoscopic Cholecystectomy
    Bilgen, Koksal
    Ustun, Murat
    Karakahya, Murat
    Isik, Sevil
    Sengul, Serkan
    Cetinkunar, Suleyman
    Kucukpinar, Tevfik H.
    SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES, 2013, 23 (02): : 180 - 183