Immediate and Long-Term Echocardiographic Findings after Transcatheter Aortic Valve Implantation for the Treatment of Aortic Stenosis: The Cribier-Edwards/Edwards-Sapien Valve Experience

被引:36
|
作者
Bauer, Fabrice [1 ,2 ]
Lemercier, Mathieu [1 ]
Zajarias, Alan
Tron, Christophe
Eltchaninoff, Helene
Cribier, Alain [1 ,2 ]
机构
[1] Rouen Univ Hosp, Div Cardiol, Rouen, France
[2] INSERM, U644, Rouen Med Sch, Res Lab, Rouen, France
关键词
Aortic stenosis; Doppler; Prosthesis; Surgery; Transcatheter heart valve implantation; PERCUTANEOUS BALLOON VALVULOPLASTY; PROSTHETIC HEART-VALVE; FOLLOW-UP; REPLACEMENT; REGURGITATION; IMPROVEMENT; IMPACT;
D O I
10.1016/j.echo.2010.01.020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The role of transcatheter aortic valve implantation in the treatment of calcific aortic stenosis is evolving. Immediate and long-term echocardiographic findings are poorly reported. Methods: Eighty-eight patients in whom surgical aortic valve replacement was contraindicated were studied before and 1 and 7 days, 1 month, and 1 and 2 years after the transcatheter procedure by echocardiography for hemodynamic. Transaortic pressure gradient, permeability index, and aortic valve area were measured, and aortic regurgitation was estimated from a multiparametric approach. A subset group of 36 patients (23-mm valve, n = 18; 26-mm valve, n = 18) with optimal ultrasound window were investigated for valve geometry at 7 days. We measured the sphericity index (anteroposterior to sagittal diameter ratio) and the angulation of the prosthesis with the ascending aorta. Results: By analysis of variance, transaortic pressure gradient significantly decreased and aortic valve area increased after the procedure (P < .0001 and P < .0001 respectively). Aortic regurgitation severity tended to decline at follow-up (P = .20) and was unaffected by valve size (P = .35). Leaks were paraprosthetic in 77% of cases, intraprosthetic in 6% of cases, and both in 17% of cases. Overall, the sphericity index was 1.03 +/- 0.07 and the angulation was 2.9 +/- 1.1 degrees. Conclusion: Echocardiography aids in the demonstration of appropriate prosthesis function and positioning after transcatheter aortic valve implantation. (J Am Soc Echocardiogr 2010;23:370-6.)
引用
收藏
页码:370 / 376
页数:7
相关论文
共 50 条
  • [41] Transcatheter Edwards Sapien XT valve in valve implantation in degenerated aortic bioprostheses via transfemoral access
    Greif, Martin
    Lange, Philipp
    Mair, Helmut
    Becker, Christoph
    Schmitz, Christoph
    Steinbeck, Gerhard
    Kupatt, Christian
    CLINICAL RESEARCH IN CARDIOLOGY, 2012, 101 (12) : 993 - 1001
  • [42] Five years experience in transapical transcatheter aortic valve implantation with the Edwards Sapien in high risk patients
    Stelzmueller, M. -E.
    Sandner, S.
    Mora, B.
    Laufer, G.
    Wisser, W.
    WIENER KLINISCHE WOCHENSCHRIFT, 2013, 125 : S61 - S62
  • [43] Transcatheter Edwards Sapien XT valve in valve implantation in degenerated aortic bioprostheses via transfemoral access
    Martin Greif
    Philipp Lange
    Helmut Mair
    Christoph Becker
    Christoph Schmitz
    Gerhard Steinbeck
    Christian Kupatt
    Clinical Research in Cardiology, 2012, 101 : 993 - 1001
  • [44] Management of Paravalvular Regurgitation After Edwards SAPIEN Transcatheter Aortic Valve Replacement
    Martinez, Claudia A.
    Singh, Vikas
    O'Neill, Brian P.
    Alfonso, Carlos E.
    Bilsker, Martin S.
    Clark, Pedro Martinez
    Williams, Donald
    Cohen, Mauricio G.
    Heldman, Alan W.
    O'Neill, William W.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (02) : 300 - 311
  • [45] Comparison of the second generation Edwards Sapien 3 valve with the Edwards Sapien XT for transfemoral aortic valve implantation (TAVI)
    Seeger, Julia
    Gonska, Birgid
    Rodewald, Christoph
    Marcovic, Sinisa
    Scharnbeck, Dominik
    Rottbauer, Wolfgang
    Woehrle, Jochen
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B258 - B258
  • [46] Edwards SAPIEN™ and Edwards SAPIEN XT™ transcatheter heart valves for the treatment of severe aortic stenosis
    Freeman, Melanie
    Webb, John G.
    EXPERT REVIEW OF MEDICAL DEVICES, 2012, 9 (06) : 563 - 569
  • [47] Transfemoral Transcatheter Aortic Valve Implantation with the Edwards Sapien Versus the Medtronic CoreValve Device
    Wiegerinck, Esther M.
    Boerlage-van Dijk, Kirsten
    Yong, Ze Yie
    Koch, Karel T.
    Vis, Marije M.
    Symersky, Petr
    Cocchieri, Ricardo
    De Mol, Bas A. J. M.
    Piek, Jan
    Tijssen, Jan G.
    Baan, Jan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (18) : B219 - B219
  • [48] Edwards SAPIEN 3 Transcatheter Heart Valve Implantation in a Native Bicuspid Aortic Regurgitation
    Nagaraja, Vinayak
    Gunning, Mark
    Ratib, Karim
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2019, 20 (11) : S70 - S71
  • [49] Transcatheter Aortic Valve Implantation (TAVI): A Single Center Experience with Core Valve and Edwards Valve
    Pasupati, Sanjeevan
    Liang, Michael
    Puri, Aniket
    Fisher, Raewyn
    Kejriwal, Nand
    Devlin, Gerard
    AMERICAN JOURNAL OF CARDIOLOGY, 2010, 105 (9A): : 115B - 115B
  • [50] Can we predict postprocedural paravalvular leak after Edwards SAPIEN transcatheter aortic valve implantation?
    Watanabe, Yusuke
    Lefevre, Thierry
    Arai, Takahide
    Hayashida, Kentaro
    Bouvier, Erik
    Hovasse, Thomas
    Romano, Mauro
    Chevalier, Bernard
    Garot, Philippe
    Donzeau-Gouge, Patrick
    Farge, Arnaud
    Cormier, Bertrand
    Morice, Marie-Claude
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 86 (01) : 144 - 151