Immediate and Long-Term Echocardiographic Findings after Transcatheter Aortic Valve Implantation for the Treatment of Aortic Stenosis: The Cribier-Edwards/Edwards-Sapien Valve Experience

被引:36
|
作者
Bauer, Fabrice [1 ,2 ]
Lemercier, Mathieu [1 ]
Zajarias, Alan
Tron, Christophe
Eltchaninoff, Helene
Cribier, Alain [1 ,2 ]
机构
[1] Rouen Univ Hosp, Div Cardiol, Rouen, France
[2] INSERM, U644, Rouen Med Sch, Res Lab, Rouen, France
关键词
Aortic stenosis; Doppler; Prosthesis; Surgery; Transcatheter heart valve implantation; PERCUTANEOUS BALLOON VALVULOPLASTY; PROSTHETIC HEART-VALVE; FOLLOW-UP; REPLACEMENT; REGURGITATION; IMPROVEMENT; IMPACT;
D O I
10.1016/j.echo.2010.01.020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The role of transcatheter aortic valve implantation in the treatment of calcific aortic stenosis is evolving. Immediate and long-term echocardiographic findings are poorly reported. Methods: Eighty-eight patients in whom surgical aortic valve replacement was contraindicated were studied before and 1 and 7 days, 1 month, and 1 and 2 years after the transcatheter procedure by echocardiography for hemodynamic. Transaortic pressure gradient, permeability index, and aortic valve area were measured, and aortic regurgitation was estimated from a multiparametric approach. A subset group of 36 patients (23-mm valve, n = 18; 26-mm valve, n = 18) with optimal ultrasound window were investigated for valve geometry at 7 days. We measured the sphericity index (anteroposterior to sagittal diameter ratio) and the angulation of the prosthesis with the ascending aorta. Results: By analysis of variance, transaortic pressure gradient significantly decreased and aortic valve area increased after the procedure (P < .0001 and P < .0001 respectively). Aortic regurgitation severity tended to decline at follow-up (P = .20) and was unaffected by valve size (P = .35). Leaks were paraprosthetic in 77% of cases, intraprosthetic in 6% of cases, and both in 17% of cases. Overall, the sphericity index was 1.03 +/- 0.07 and the angulation was 2.9 +/- 1.1 degrees. Conclusion: Echocardiography aids in the demonstration of appropriate prosthesis function and positioning after transcatheter aortic valve implantation. (J Am Soc Echocardiogr 2010;23:370-6.)
引用
收藏
页码:370 / 376
页数:7
相关论文
共 50 条
  • [31] Transcatheter Aortic Valve Replacement with Edwards Sapien Valve for Treatment of Degenerated Bioprosthesis: UK Sapien User Group Experience
    Bapat, Vinnie
    Douglas, Muir
    Wendler, Olaf
    Thomas, Mathew
    Lloyd, Clinton
    Doshi, Sagar
    Rana, Sayeed
    Densem, Cameron
    Gunning, Mark
    Kuduvalli, Manoj
    Thomas, Martyn
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B36 - B36
  • [32] Numerical analysis of the radial force produced by the Medtronic-CoreValve and Edwards-SAPIEN after transcatheter aortic valve implantation (TAVI)
    Tzamtzis, S.
    Viquerat, J.
    Yap, J.
    Mullen, M. J.
    Burriesci, G.
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (01) : 125 - 130
  • [33] LONG TERM DURABILITY OF EDWARDS BALLOON EXPANDABLE TRANSCATHETER AORTIC VALVE IMPLANTATION
    Gurvitch, Ronen
    Tay, Edgar
    Cheung, Anson
    Nietlispach, Fabian
    Ye, Jian
    Wood, David A.
    Thompson, Chris
    Wijesinghe, Namal
    Leipsic, Jonathon
    Lichtenstein, Samuel V.
    Webb, John G.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [34] Transfemoral aortic valve implantation is more successful with the Edwards Sapien 3 compared with the Edwards XT for the treatment of symptomatic severe aortic stenosis
    Gonska, Birgid
    Seeger, Julia
    Junker, Alexander
    Rodewald, Christoph
    Trepte, Ulrike
    Scharnbeck, Dominik
    Rottbauer, Wolfgang
    Woehrle, Jochen
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2018, 111 (8-9) : 470 - 479
  • [35] Conduction Abnormalities May Be Transient Following Transcatheter Aortic Valve Replacement with the Edwards-Sapien Prosthesis
    Baltodano, Pablo
    Sager, Solomon I.
    O'Neill, Brian P.
    Shah, Sachil
    Martinez, Claudia A.
    Alfonso, Carlos E.
    Martinez-Clark, Pedro
    Cohen, Mauricio G.
    Heldman, Alan W.
    O'Neill, William W.
    Williams, Donald
    Carrillo, Roger G.
    CIRCULATION, 2012, 126 (21)
  • [36] Transfemoral Aortic Valve Implantation with the New Edwards Sapien 3 Valve for Treatment of Severe Aortic Stenosis-Impact of Valve Size in a Single Center Experience
    Woehrle, Jochen
    Gonska, Birgid
    Rodewald, Christoph
    Seeger, Julia
    Scharnbeck, Dominik
    Rottbauer, Wolfgang
    PLOS ONE, 2016, 11 (03):
  • [37] Left Bundle Branch Block after Transcatheter Aortic Valve Implantation with Edwards Sapien 3 Valve: Influence of the Valve Depth Implantation
    Unzue, Leire
    Garcia, Eulogio
    Diaz-Anton, Belen
    Jose Rodriguez-Rodrigo, Francisco
    Rodriguez del Rio, Miguel
    Teijeiro, Rodrigo
    Medina, Juan
    Javier Parra, Francisco
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2019, 20 (11) : 949 - 955
  • [38] Transapical Transcatheter Treatment of a Stenosed Aortic Valve Bioprosthesis Using the Edwards SAPIEN Transcatheter Heart Valve
    Klaaborg, Kaj-Erik
    Egeblad, Henrik
    Jakobsen, Carl-Johan
    Lindskov, Christian
    Andersen, Henning Rud
    Thuesen, Leif
    ANNALS OF THORACIC SURGERY, 2009, 87 (06): : 1943 - 1946
  • [39] The Edwards SAPIEN Transcatheter Heart Valve for Calcific Aortic Stenosis: A Review of the Valve, Procedure, and Current Literature
    Holoshitz N.
    Kavinsky C.J.
    Hijazi Z.M.
    Cardiology and Therapy, 2012, 1 (1) : 1 - 17
  • [40] Transaortic Transcatheter Aortic Valve Implantation With the Edwards Sapien Valve: Feasibility, Technical Considerations, and Clinical Advantages
    Etienne, Pierre-Yves
    Papadatos, Spiridon
    El Khoury, Elie
    Pieters, Denis
    Price, Joel
    Glineur, David
    ANNALS OF THORACIC SURGERY, 2011, 92 (02): : 746 - 748