Assessment of three-dimensional setup errors in image-guided pelvic radiotherapy for uterine and cervical cancer using kilovoltage cone-beam computed tomography and its effect on planning target volume margins

被引:38
|
作者
Patni, Nidhi [1 ]
Burela, Nagarjuna [1 ]
Pasricha, Rajesh [2 ]
Goyal, Jaishree [1 ]
Soni, Tej Prakash [1 ]
Kumar, T. Senthil [1 ]
Natarajan, T. [1 ]
机构
[1] Bhagwan Mahaveer Canc Hosp & Res Ctr, Dept Radiat Oncol, JLN Marg, Jaipur, Rajasthan, India
[2] GBH Amer Hosp, Dept Radiat Oncol, Udaipur, Rajasthan, India
关键词
Gynecological malignancy; image guidance; kilovoltage cone-beam computed tomography; margins; setup errors; INTERFRACTIONAL VARIATION; PATIENT SETUP; UP ERRORS; UNCERTAINTIES; ACCURACY; POSITION; IMPACT; TUMOR;
D O I
10.4103/0973-1482.199451
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To achieve the best possible therapeutic ratio using high-precision techniques (image-guided radiation therapy/volumetric modulated arc therapy [IGRT/VMAT]) of external beam radiation therapy in cases of carcinoma cervix using kilovoltage cone-beam computed tomography (kV-CBCT). Materials and Methods: One hundred and five patients of gynecological malignancies who were treated with IGRT (IGRT/VMAT) were included in the study. CBCT was done once a week for intensity-modulated radiation therapy and daily in IGRT/VMAT. These images were registered with the planning CT scan images and translational errors were applied and recorded. In all, 2078 CBCT images were studied. The margins of planning target volume were calculated from the variations in the setup. Results: The setup variation was 5.8, 10.3, and 5.6 mm in anteroposterior, superoinferior, and mediolateral direction. This allowed adequate dose delivery to the clinical target volume and the sparing of organ at risks. Conclusion: Daily kV-CBCT is a satisfactory method of accurate patient positioning in treating gynecological cancers with high-precision techniques. This resulted in avoiding geographic miss.
引用
收藏
页码:131 / 136
页数:6
相关论文
共 50 条
  • [41] On-Line Use of Three-Dimensional Marker Trajectory Estimation From Cone-Beam Computed Tomography Projections for Precise Setup in Radiotherapy for Targets With Respiratory Motion
    Worm, Esben S.
    Hoyer, Morten
    Fledelius, Walther
    Nielsen, Jens E.
    Larsen, Lars P.
    Poulsen, Per R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (01): : E145 - E151
  • [42] IMAGE-GUIDED RADIOTHERAPY (IGRT) FOR PROSTATE CANCER: EFFECT OF RESIDUAL SET-UP ERRORS AND INTRA-FRACTIONAL MOTION ON PLANNING TARGET VOLUME (PTV) MARGINS.
    Benson, R.
    Rimmer, Y.
    Tudor, S.
    Dean, J.
    Muskett, N.
    Patterson, H.
    Russell, S.
    Woodward, C.
    Fairfoul, J.
    Doble, A.
    Burnet, N.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S373 - S373
  • [43] The Effect of Registration Volume Extent on Residual Errors Assessed Using Cone-Beam Computed Tomography in Radiation Treatment of Head and Neck Cancer
    Morley, Lyndon
    Waldron, John
    Dawson, Laura
    Bayley, Andrew
    Ringash, Jolie
    Cummings, Bernard
    Kim, John
    O'Sullivan, Brian
    Breen, Stephen L.
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2012, 43 (02) : 95 - 102
  • [44] Impact of four-dimensional cone-beam computed tomography on target localization for gastric mucosa-associated lymphoid tissue lymphoma radiotherapy: reducing planning target volume
    Yoshinobu Shimohigashi
    Ryo Toya
    Tetsuo Saito
    Yumiko Kono
    Yasuhiro Doi
    Yoshiyuki Fukugawa
    Takahiro Watakabe
    Tadashi Matsumoto
    Yudai Kai
    Masato Maruyama
    Natsuo Oya
    Radiation Oncology, 16
  • [45] Impact of four-dimensional cone-beam computed tomography on target localization for gastric mucosa-associated lymphoid tissue lymphoma radiotherapy: reducing planning target volume
    Shimohigashi, Yoshinobu
    Toya, Ryo
    Saito, Tetsuo
    Kono, Yumiko
    Doi, Yasuhiro
    Fukugawa, Yoshiyuki
    Watakabe, Takahiro
    Matsumoto, Tadashi
    Kai, Yudai
    Maruyama, Masato
    Oya, Natsuo
    RADIATION ONCOLOGY, 2021, 16 (01)
  • [46] Evaluation of interfractional variation of the centroid position and volume of internal target volume during stereotactic body radiotherapy of lung cancer using cone-beam computed tomography
    Sun, Yanan
    Ge, Hong
    Cheng, Siguo
    Yang, Chengliang
    Zhu, Qianqian
    Li, Dingjie
    Tian, Yuan
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (02): : 461 - 472
  • [47] Does the planning dose-volume histogram represent treatment doses in image-guided prostate radiation therapy? Assessment with cone-beam computerised tomography scans
    Hatton, Joan A.
    Greer, Peter B.
    Tang, Colin
    Wright, Philip
    Capp, Anne
    Gupta, Sanjiv
    Parker, Joel
    Wratten, Chris
    Denham, James W.
    RADIOTHERAPY AND ONCOLOGY, 2011, 98 (02) : 162 - 168
  • [48] A Collaborative Analysis of Stereotactic Lung Radiotherapy Outcomes for Early-Stage Non-Small-Cell Lung Cancer Using Daily Online Cone-Beam Computed Tomography Image-Guided Radiotherapy
    Grills, Inga Siiner
    Hope, Andrew J.
    Guckenberger, Matthias
    Kestin, Larry L.
    Werner-Wasik, Maria
    Yan, Di
    Sonke, Jan-Jakob
    Bissonnette, Jean-Pierre
    Wilbert, Juergen
    Xiao, Ying
    Belderbos, Jose
    JOURNAL OF THORACIC ONCOLOGY, 2012, 7 (09) : 1382 - 1393
  • [49] Factors That Guide the Diagnosis and Treatment Planning for Impacted Canines Using Three-Dimensional Cone-Beam Computed Tomography: A Cross-Sectional Study
    Hasan, Hasan Sabah
    Elkolaly, Mohamed A.
    Elmoazen, Ramy
    Kolemen, Ayshan
    Al Azzawi, Arkan Muslim
    INTERNATIONAL JOURNAL OF DENTISTRY, 2022, 2022
  • [50] Evaluation of Target Volume Location and Its Impact on Delivered Dose Using Cone-Beam Computed Tomography Scans for Patients with Head and Neck Cancer
    Grover, Devyn
    Laraque, Malcolm
    Debenham, Brock
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2019, 50 (03) : 387 - 397