Assessment of three-dimensional setup errors in image-guided pelvic radiotherapy for uterine and cervical cancer using kilovoltage cone-beam computed tomography and its effect on planning target volume margins

被引:38
|
作者
Patni, Nidhi [1 ]
Burela, Nagarjuna [1 ]
Pasricha, Rajesh [2 ]
Goyal, Jaishree [1 ]
Soni, Tej Prakash [1 ]
Kumar, T. Senthil [1 ]
Natarajan, T. [1 ]
机构
[1] Bhagwan Mahaveer Canc Hosp & Res Ctr, Dept Radiat Oncol, JLN Marg, Jaipur, Rajasthan, India
[2] GBH Amer Hosp, Dept Radiat Oncol, Udaipur, Rajasthan, India
关键词
Gynecological malignancy; image guidance; kilovoltage cone-beam computed tomography; margins; setup errors; INTERFRACTIONAL VARIATION; PATIENT SETUP; UP ERRORS; UNCERTAINTIES; ACCURACY; POSITION; IMPACT; TUMOR;
D O I
10.4103/0973-1482.199451
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To achieve the best possible therapeutic ratio using high-precision techniques (image-guided radiation therapy/volumetric modulated arc therapy [IGRT/VMAT]) of external beam radiation therapy in cases of carcinoma cervix using kilovoltage cone-beam computed tomography (kV-CBCT). Materials and Methods: One hundred and five patients of gynecological malignancies who were treated with IGRT (IGRT/VMAT) were included in the study. CBCT was done once a week for intensity-modulated radiation therapy and daily in IGRT/VMAT. These images were registered with the planning CT scan images and translational errors were applied and recorded. In all, 2078 CBCT images were studied. The margins of planning target volume were calculated from the variations in the setup. Results: The setup variation was 5.8, 10.3, and 5.6 mm in anteroposterior, superoinferior, and mediolateral direction. This allowed adequate dose delivery to the clinical target volume and the sparing of organ at risks. Conclusion: Daily kV-CBCT is a satisfactory method of accurate patient positioning in treating gynecological cancers with high-precision techniques. This resulted in avoiding geographic miss.
引用
收藏
页码:131 / 136
页数:6
相关论文
共 50 条
  • [31] The potential failure risk of the cone-beam computed tomography-based planning target volume margin definition for prostate image-guided radiotherapy based on a prospective single-institutional hybrid analysis
    Katsumi Hirose
    Mariko Sato
    Yoshiomi Hatayama
    Hideo Kawaguchi
    Fumio Komai
    Makoto Sohma
    Hideki Obara
    Masashi Suzuki
    Mitsuki Tanaka
    Ichitaro Fujioka
    Koji Ichise
    Yoshihiro Takai
    Masahiko Aoki
    Radiation Oncology, 13
  • [32] Dose estimation for cone-beam computed tomography in image-guided radiation therapy for pelvic cancer using adult mesh-type reference computational phantoms
    Cumur, Ceyda
    Fujibuchi, Toshioh
    Arakawa, Hiroyuki
    Hamada, Keisuke
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2023, 16 (02) : 203 - 211
  • [33] Dose estimation for cone-beam computed tomography in image-guided radiation therapy for pelvic cancer using adult mesh-type reference computational phantoms
    Ceyda Cumur
    Toshioh Fujibuchi
    Hiroyuki Arakawa
    Keisuke Hamada
    Radiological Physics and Technology, 2023, 16 : 203 - 211
  • [34] Three-dimensional Assessment of Temporomandibular Joint Volume, and Condylar and Glenoid-fossa Morphology: A Cone-beam Computed Tomography Study
    Mehta, Shivam
    Gandhi, Vaibhav
    Patel, Apexa
    Chen, Po-Jung
    Lin, Meng-Hsuan
    Kuo, Chia-Ling
    Tadinada, Aditya
    Yadav, Sumit
    CONTEMPORARY CLINICAL DENTISTRY, 2023, 14 (04) : 256 - +
  • [35] Dosimetric analysis between Manchester points "A" and high-risk clinical target volume in the three-dimensional image-guided branchytherapy for uterine cervical cancer
    Chacon-Anaya, Silvia C.
    Duran-Cruz, Mauricio
    Reding-Bernal, Arturo
    Barragan-Perez, Jose A.
    GACETA MEXICANA DE ONCOLOGIA, 2021, 20 (01): : 1 - 8
  • [36] Anisotropic Bladder Planning Target Volume is Adequate When Using Cone Beam Computed Tomography as a Form of Image Guided Radiation Therapy
    Adil, K.
    Popovic, M.
    Cury, F. L.
    Faria, S.
    Souhami, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E210 - E210
  • [37] Target repositional accuracy and PTV margin verification using three-dimensional cone-beam computed tomography (CBCT) in stereotactic body radiotherapy (SBRT) of lung cancers
    Wang, Lu
    Feigenberg, Steven
    Fan, Jiajin
    Jin, Lihui
    Turaka, Aruna
    Chen, Lili
    Ma, C-M Charlie
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (02): : 41 - 54
  • [38] Target Relocalization Accuracy and PTV Margin Verification Using Three-Dimensional Cone-Beam Computed Tomography (CBCT) in Stereotactic Body Radiotherapy (SBRT) of Lung Cancers
    Wang, L.
    Feigenberg, S.
    Lally, B.
    Fan, J.
    Jin, L.
    Chen, L.
    Price, R.
    Ma, C.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [39] Comparison between manual and automatic image registration in image-guided radiation therapy using megavoltage cone-beam computed tomography with an imaging beam line for prostate cancer
    Hashido T.
    Nakasone S.
    Fukao M.
    Ota S.
    Inoue S.
    Radiological Physics and Technology, 2018, 11 (4) : 392 - 405
  • [40] Effect of interproximal enamel reduction on interradicular bone volume in clear aligner therapy: a three-dimensional cone-beam computed tomography study
    Darwiche, Fadia Hussein
    Tashkandi, Nada E.
    AlGhamdi, Maher
    AlMuhaish, Luba Abdulrahman
    Shahin, Suliman Y.
    CLINICAL ORAL INVESTIGATIONS, 2024, 28 (10)