Echocardiographic outflow pump ramp test in centrifugal-flow left ventricular assist device

被引:3
|
作者
Iacovoni, Attilio [1 ]
Vittori, Claudia [1 ]
Fontana, Alessandra [1 ]
Carobbio, Alessandra [2 ]
Fino, Carlo [1 ]
D'Elia, Emilia [1 ]
Terzi, Amedeo [1 ]
Senni, Michele [1 ]
机构
[1] Reg Healthcare & Social Serv ASST, Cardiovasc Dept, Papa Giovanni Hosp 23, Bergamo, Italy
[2] Reg Healthcare & Social Serv ASST, FROM Res Fdn, Papa Giovanni Hosp 23, Bergamo, Italy
来源
关键词
Advanced heart failure; Left ventricular assist device; Pump thrombosis; SPEED OPTIMIZATION; THROMBOSIS; SYSTEM;
D O I
10.5301/ijao.5000573
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study sought to develop a novel echocardiogram outflow ramp test to detect device malfunctions in centrifugal-flow left ventricular assist devices (LVADs). This new ramp pump test is based on the direct analyses of systolic and diastolic ratio (S/D) Doppler velocity in the outflow cannula in the HeartWare LVAD during progressive increases in speed. The results showed that in patients with normal pump function, the Doppler velocity S/D ratio gradually decreased during LVAD speed increases. This test is easily performed and seems promising to detect normal pump function in patients assisted by a centrifugal flow LVAD.
引用
收藏
页码:128 / 131
页数:4
相关论文
共 50 条
  • [41] Echocardiographic evaluation of left ventricular assist device function
    Song, A
    Paulsen, W
    Akosah, KO
    Tolman, DE
    Guerraty, AL
    Mohanty, PK
    CIRCULATION, 1997, 96 (08) : 2083 - 2083
  • [42] Validation of Intrinsic Left Ventricular Assist Device Data Tracking Algorithm for Early Recognition of Centrifugal Flow Pump Thrombosis
    Gross, Christoph
    Dimitrov, Kamen
    Riebandt, Julia
    Wiedemann, Dominik
    Laufer, Guenther
    Schima, Heinrich
    Moscato, Francesco
    Brown, Michael C.
    Kadrolkar, Abhijit
    Stadler, Robert W.
    Zimpfer, Daniel
    Schloeglhofer, Thomas
    LIFE-BASEL, 2022, 12 (04):
  • [43] Acute kidney injury after implantation of a left ventricular assist device: a comparison of axial-flow (HeartMate II) and centrifugal-flow (HeartWare HVAD) devices
    Anjum, Azeen
    Kurihara, Chitaru
    Critsinelis, Andre
    Kawabori, Masashi
    Sugiura, Tadahisa
    Civitello, Andrew B.
    Etheridge, Whitson B.
    Delgado, Reynolds M.
    Simpson, Leo
    George, Joggy K.
    Nair, Ajith P.
    Frazier, O. H.
    Morgan, Jeffrey A.
    JOURNAL OF ARTIFICIAL ORGANS, 2018, 21 (03) : 285 - 292
  • [44] A simplified echocardiographic technique for detecting continuous-flow left ventricular assist device malfunction due to pump thrombosis
    Estep, Jerry D.
    Vivo, Rey P.
    Cordero-Reyes, Andrea M.
    Bhimaraj, Arvind
    Trachtenberg, Barry H.
    Torre-Amione, Guillermo
    Chang, Su Min
    Elias, Barbara
    Bruckner, Brian A.
    Suarez, Erik E.
    Loebe, Matthias
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (06): : 575 - 586
  • [45] Pump thrombosis and dynamic outflow graft compression: complications in left ventricular assist device therapy
    Dobner, Stephan
    Grani, Christoph
    Hugi-Mayr, Beate
    Mihalj, Maks
    Rhyner, Daniel
    Wieser, Monika
    Martinelli, Michele
    Hunziker, Lukas
    Reineke, David
    ESC HEART FAILURE, 2021, 8 (02): : 1631 - 1636
  • [46] Acute kidney injury after implantation of a left ventricular assist device: a comparison of axial-flow (HeartMate II) and centrifugal-flow (HeartWare HVAD) devices
    Azeen Anjum
    Chitaru Kurihara
    Andre Critsinelis
    Masashi Kawabori
    Tadahisa Sugiura
    Andrew B. Civitello
    Whitson B. Etheridge
    Reynolds M. Delgado
    Leo Simpson
    Joggy K. George
    Ajith P. Nair
    O. H. Frazier
    Jeffrey A. Morgan
    Journal of Artificial Organs, 2018, 21 : 285 - 292
  • [47] Transoesophageal echocardiographic Doppler colour flow patterns of a normally functioning third-generation centrifugal left ventricular assist device
    Najib, Mohammad Q.
    Ganji, Jhansi L.
    Pierce, Christopher N.
    Arabia, Francisco A.
    Chaliki, Hari P.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2012, 13 (04) : 362 - 363
  • [48] Long-term in vivo left ventricular assist device study with a titanium centrifugal pump
    Ohtsuka, G
    Nakata, K
    Yoshikawa, M
    Mueller, J
    Takano, T
    Yamane, S
    Gronau, N
    Glueck, J
    Takami, Y
    Sueoka, A
    Letsou, G
    Schima, H
    Schmallegger, H
    Wolner, E
    Koyanagi, H
    Fujisawa, A
    Baldwin, JC
    Nose, Y
    ASAIO JOURNAL, 1998, 44 (05) : M619 - M623
  • [49] Comparison of the Hemocompatibility of an Axial and a Centrifugal Left Ventricular Assist Device in an In Vitro Test Circuit
    Borchers, Patrick
    Winnersbach, Patrick
    Kraemer, Sandra
    Beckers, Christian
    Buhl, Eva Miriam
    Leonhardt, Steffen
    Rossaint, Rolf
    Walter, Marian
    Breuer, Thomas
    Bleilevens, Christian
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (12)
  • [50] Long-term in vivo left ventricular assist device study with a titanium centrifugal pump
    Ohtsuka, Goro
    Nakata, Kin-Ichi
    Yoshikawa, Masaharu
    Mueller, Juergen
    Takano, Tamaki
    Yamane, Shingo
    Gronau, Nicole
    Glueck, Julia
    Takami, Yoshiyuki
    Sueoka, Akinori
    Letsou, George
    Schima, Heinrich
    Schmallegger, Helmut
    Wolner, Ernst
    Koyanagi, Hitoshi
    Fujisawa, Akira
    Baldwin, John C.
    Nosé, Yukihiko
    ASAIO Journal, 44 (05):