A simplified echocardiographic technique for detecting continuous-flow left ventricular assist device malfunction due to pump thrombosis

被引:30
|
作者
Estep, Jerry D. [1 ]
Vivo, Rey P. [1 ,2 ]
Cordero-Reyes, Andrea M. [1 ]
Bhimaraj, Arvind [1 ]
Trachtenberg, Barry H. [1 ]
Torre-Amione, Guillermo [1 ,3 ]
Chang, Su Min [1 ]
Elias, Barbara [1 ]
Bruckner, Brian A. [1 ]
Suarez, Erik E. [1 ]
Loebe, Matthias [1 ]
机构
[1] Houston Methodist DeBakey Heart & Vasc Ctr, Houston, TX USA
[2] Univ Calif Los Angeles, Ahmanson Cardiomyopathy Ctr, Mech & Circulatory Support & Heart Transplantat P, Los Angeles, CA USA
[3] Catedra Cardiol & Med Vasc Tecnol Monterrey, Monterrey, Nuevo Leon, Mexico
来源
关键词
heart failure; left ventricular assist device; thrombosis; echocardiography; cardiomyopathy; AMERICAN-SOCIETY; INTERNATIONAL SOCIETY; EUROPEAN-ASSOCIATION; STANDARDS COMMITTEE; HEART-FAILURE; TASK-FORCE; RECOMMENDATIONS; GUIDELINES; DIAGNOSIS; QUANTIFICATION;
D O I
10.1016/j.healun.2014.01.865
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Malfunction of a continuous-flow left ventricular assist device (CF-LVAD) due to device thrombosis is a potentially life-threatening event that currently presents a diagnostic challenge. We aimed to propose a practical echocardiographic assessment to diagnose LVAD malfunction secondary to pump thrombosis. METHODS: Among 52 patients implanted with a CF-LVAD from a single center who underwent echocardiographic pump speed-change testing, 12 had suspected pump thrombosis as determined by clinical, laboratory, and/or device parameters. Comprehensive echocardiographic evaluation was performed at baseline pump speed and at each 1,000-rpm interval from the low setting of 8,000 rpm to the high setting of 11,000 rpm in 11 of these patients. RESULTS: Receiver operating characteristic curves and stepwise logistic regression analyses showed that the best diagnostic parameters included changes in the LV end-diastolic diameter (<0.6 cm), aortic valve opening time (<80 msec), and deceleration time of mitral inflow (<70 msec) from lowest to highest pump speed. One parameter was predictive of pump malfunction, with 100% sensitivity and 89% specificity, whereas 2 of 3 parameters increased the sensitivity to 100% and specificity to 95%. CONCLUSIONS: The 3 echocardiographic variables of measured changes in LV end-diastolic diameter, aortic valve opening time, and deceleration time of mitral inflow between the lowest (8,000 rpm) and highest pump speed settings (11,000 rpm) during echo-guided pump speed-change testing appear highly accurate in diagnosing device malfunction in the setting of pump thrombosis among patients supported with CF-LVAD. Further investigation is warranted to create and validate a prediction score. (C) 2014 International Society for Heart and Lung Transplantation. All rights reserved.
引用
收藏
页码:575 / 586
页数:12
相关论文
共 50 条
  • [1] Echocardiographic Findings in Continuous-Flow Left Ventricular Assist Device Pump Thrombosis
    Ortega-Legaspi, Juan M.
    Airhart, Sophia
    Hoang Nguyen
    Masri, S. Carolina
    Kirkpatrick, James
    JOURNAL OF CARDIAC FAILURE, 2016, 22 (08) : S117 - S117
  • [2] Continuous-Flow Left Ventricular Assist Device Thrombosis: A Solvable Problem
    Pagani, Francis D.
    ASAIO JOURNAL, 2016, 62 (01) : 3 - 5
  • [3] Acoustic Analysis of a Continuous-Flow Left Ventricular Assist Device before and after Suspected Pump Thrombosis
    Castagna, F.
    Pan, S.
    Garan, A. R.
    Yuzefpolskaya, M.
    Takeda, K.
    Takayama, H.
    Ross, K.
    Torres, M.
    Blum, R. A.
    Singh, S.
    Mancini, D. M.
    Naka, Y.
    Colombo, P. C.
    Bulek, S.
    Topkara, V. K.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (04): : S326 - S326
  • [4] Recurrent pump thrombosis is common after axial continuous-flow left ventricular assist device exchange
    Urban, Marian
    Um, John
    Moulton, Michael
    Stoller, Douglas
    Zolty, Ronald
    Lowes, Brian
    Macdonald, Collin
    McCain, Natalia
    Siddique, Aleem
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2020, 43 (02): : 109 - 118
  • [5] Arterial Compliance and Continuous-Flow Left Ventricular Assist Device Pump Function
    Adji, Audrey
    Shehab, Sajad
    Jain, Pankaj
    Robson, Desiree
    Jansz, Paul
    Hayward, Christopher S.
    ASAIO JOURNAL, 2022, 68 (07) : 925 - 931
  • [6] Off-Pump Continuous-Flow Left Ventricular Assist Device Implantation
    De Armas, Ismael A. Salas
    Patel, Jayeshkumar A.
    Akay, Mehmet H.
    Patel, Manish K.
    Rajagopal, Keshava
    Karabulut, Mehmet N.
    Kar, Biswajit
    Gregoric, Igor D.
    TEXAS HEART INSTITUTE JOURNAL, 2021, 48 (01)
  • [7] A Novel and Simple Echocardiographic Tool To Detect Malfunction of Continuous-Flow Left Ventricular Assist Devices during Speed Change Testing: The LVAD Pump Thrombosis Score
    Estep, Jerry D.
    Vivo, Rey P.
    Cordero-Reyes, Andrea M.
    Elias, Barbara
    Bruckner, Brian
    Loebe, Matthias
    Torre-Amione, Guillermo
    Trachtenberg, Barry
    Bhimaraj, Arvind
    JOURNAL OF CARDIAC FAILURE, 2013, 19 (08) : S60 - S61
  • [8] Continuous-Flow Left Ventricular Assist Device REPLY
    Slaughter, Mark S.
    Rogers, Joseph G.
    NEW ENGLAND JOURNAL OF MEDICINE, 2010, 362 (12): : 1149 - 1149
  • [9] Effect of Alteration in Pump Speed on Pump Output and Left Ventricular Filling with Continuous-Flow Left Ventricular Assist Device
    Hayward, Christopher S.
    Salamonsen, Robert
    Keogh, Anne M.
    Woodard, John
    Ayre, Peter
    Prichard, Roslyn
    Walker, Robyn
    Kotlyar, Eugene
    Macdonald, Peter S.
    Jansz, Paul
    Spratt, Phillip
    ASAIO JOURNAL, 2011, 57 (06) : 495 - 500
  • [10] Device Thrombosis With Continuous-Flow Left Ventricular Assist Devices: Is Kounis Syndrome Involved?
    Kounis, Nicholas G.
    Soufras, George D.
    Tsigkas, Grigorios
    Hahalis, George
    ARTIFICIAL ORGANS, 2014, 38 (06) : 521 - 523