A simplified echocardiographic technique for detecting continuous-flow left ventricular assist device malfunction due to pump thrombosis

被引:30
|
作者
Estep, Jerry D. [1 ]
Vivo, Rey P. [1 ,2 ]
Cordero-Reyes, Andrea M. [1 ]
Bhimaraj, Arvind [1 ]
Trachtenberg, Barry H. [1 ]
Torre-Amione, Guillermo [1 ,3 ]
Chang, Su Min [1 ]
Elias, Barbara [1 ]
Bruckner, Brian A. [1 ]
Suarez, Erik E. [1 ]
Loebe, Matthias [1 ]
机构
[1] Houston Methodist DeBakey Heart & Vasc Ctr, Houston, TX USA
[2] Univ Calif Los Angeles, Ahmanson Cardiomyopathy Ctr, Mech & Circulatory Support & Heart Transplantat P, Los Angeles, CA USA
[3] Catedra Cardiol & Med Vasc Tecnol Monterrey, Monterrey, Nuevo Leon, Mexico
来源
关键词
heart failure; left ventricular assist device; thrombosis; echocardiography; cardiomyopathy; AMERICAN-SOCIETY; INTERNATIONAL SOCIETY; EUROPEAN-ASSOCIATION; STANDARDS COMMITTEE; HEART-FAILURE; TASK-FORCE; RECOMMENDATIONS; GUIDELINES; DIAGNOSIS; QUANTIFICATION;
D O I
10.1016/j.healun.2014.01.865
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Malfunction of a continuous-flow left ventricular assist device (CF-LVAD) due to device thrombosis is a potentially life-threatening event that currently presents a diagnostic challenge. We aimed to propose a practical echocardiographic assessment to diagnose LVAD malfunction secondary to pump thrombosis. METHODS: Among 52 patients implanted with a CF-LVAD from a single center who underwent echocardiographic pump speed-change testing, 12 had suspected pump thrombosis as determined by clinical, laboratory, and/or device parameters. Comprehensive echocardiographic evaluation was performed at baseline pump speed and at each 1,000-rpm interval from the low setting of 8,000 rpm to the high setting of 11,000 rpm in 11 of these patients. RESULTS: Receiver operating characteristic curves and stepwise logistic regression analyses showed that the best diagnostic parameters included changes in the LV end-diastolic diameter (<0.6 cm), aortic valve opening time (<80 msec), and deceleration time of mitral inflow (<70 msec) from lowest to highest pump speed. One parameter was predictive of pump malfunction, with 100% sensitivity and 89% specificity, whereas 2 of 3 parameters increased the sensitivity to 100% and specificity to 95%. CONCLUSIONS: The 3 echocardiographic variables of measured changes in LV end-diastolic diameter, aortic valve opening time, and deceleration time of mitral inflow between the lowest (8,000 rpm) and highest pump speed settings (11,000 rpm) during echo-guided pump speed-change testing appear highly accurate in diagnosing device malfunction in the setting of pump thrombosis among patients supported with CF-LVAD. Further investigation is warranted to create and validate a prediction score. (C) 2014 International Society for Heart and Lung Transplantation. All rights reserved.
引用
收藏
页码:575 / 586
页数:12
相关论文
共 50 条
  • [21] Percutaneous deactivation of a left ventricular assist device due to pump thrombosis
    Bohdan, Michal
    Kolaczkowska, Magdalena
    Radtke-Lysek, Alicja
    Targonski, Radoslaw
    Siondalski, Piotr
    Rogowski, Jan
    Gruchala, Marcin
    KARDIOLOGIA POLSKA, 2023, 81 (7-8) : 796 - 797
  • [22] Device thrombosis in HeartMate II continuous-flow Left ventricular assist devices: A multifactorial phenomenon
    Uriel, Nir
    Han, Jason
    Morrison, Kerry A.
    Nahumi, Nadav
    Yuzefpolskaya, Melana
    Garan, Arthur R.
    Duong, Jimmy
    Colombo, Paolo C.
    Takayama, Hiroo
    Thomas, Sunu
    Naka, Yoshifumi
    Jorde, Ulrich P.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (01): : 51 - 59
  • [23] Device thrombosis in continuous-flow left ventricular assist devices: A new manifestation of Kounis syndrome?
    Kounis, Nicholas G.
    Soufras, George D.
    Davlouros, Periklis
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (06): : 665 - 665
  • [24] Minimally invasive, off-pump explant of a continuous-flow left ventricular assist device
    Cheung, Anson
    Bashir, Jamil
    Kaan, Annemarie
    Kealy, Jennifer
    Moss, Robert
    Shayan, Hossein
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (07): : 808 - 810
  • [25] Clinical Durability and Low Incidence of Pump Replacement of a Continuous-Flow Left Ventricular Assist Device
    Moazami, N.
    Ewald, G. A.
    Pagant, F. D.
    John, R.
    MacGillivray, T. E.
    Chen, L.
    Dembitsky, W. P.
    Farrar, D. J.
    Frazier, O. H.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (02): : S207 - S207
  • [26] Hemolysis, Pump Thrombus, and Neurologic Events in Continuous-Flow Left Ventricular Assist Device Recipients
    Whitson, Bryan A.
    Eckman, Peter
    Kamdar, Forum
    Lacey, Alexandra
    Shumway, Sara J.
    Liao, Kenneth K.
    John, Ranjit
    ANNALS OF THORACIC SURGERY, 2014, 97 (06): : 2097 - 2103
  • [27] Increased Platelet Glycoprotein IIb/IIIa Activation Precedes Continuous-Flow Left Ventricular Assist Device Pump Thrombosis Events
    Weiland, M.
    Schuitema, J.
    Jovinge, S.
    Lee, S.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2020, 39 (04): : S148 - S148
  • [28] Increased platelet glycoprotein IIb/IIIa activation precedes continuous-flow left ventricular assist device pump thrombosis events
    Weiland, Matthew
    Schuitema, Jennifer
    Jovinge, Stefan
    Lee, Sangjin
    THROMBOSIS RESEARCH, 2021, 201 : 143 - 146
  • [29] The Successful Implantation of Continuous-Flow Left Ventricular Assist Device as a Destination Therapy in Korea: Echocardiographic Assessment
    Lee, Ga Yeon
    Park, Sung-Ji
    Kim, Sujin
    Choi, Namgyung
    Jeong, Dong Seop
    Jeon, Eun-Seok
    Lee, Young Tak
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2014, 29 (01) : 137 - 140
  • [30] Medical Management of Device Thrombosis in Continuous-Flow Left Ventricular Assist Device Patients: Success Rate and Outcomes
    Coromilas, E.
    Garan, R.
    Yuzefpolskaya, M.
    Takayama, H.
    Takeda, K.
    Farr, M.
    Naka, Y.
    Colombo, P. C.
    Topkara, V. K.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (04): : S254 - S255